When you double click a bar after a steel verification, you might see the warning:
Cause
EN 1993-1-1 §6.2.6 (6) states that shear buckling for webs without intermediate stiffeners should be checked according to EN 1993-1-5 if
Diamonds shows the warning when the condition is met.