When you run the steel verification on a profile, you get the error:

Cause

  • Diamonds cannot calculate the effective properties for an CHS-section of class 4.
    On top of that, thin walled CHS-cross sections can be seen as a shell structure. EN 1993-1-6 defines the strength and stability rules for shell structures. Diamonds does not support this part of Eurocode.
  • Diamonds can calculate the effective properties for some cross-section shapes. However, these calculations are only compatible with Eurocode.