• Impossible to calculate structure. Few properties for bars are missing.

    When you try to calculate a model, you see the error: Impossible to calculate structure: Few properties for bars are missing. [NL]: Niet mogelijk om structuur te berekenen. Enkele staafgegevens ontbreken. [FR]: Impossible de calculer la structure: Quelques propertiétés de barres sont manquantes. [ES]: Imposible calcular la estructura: Faltan algunas…

  • Field not found: DiamondsLibrary.SoilSettings.RemovedGroundDivisions

    On launching the elastic analyis by means of the calculator icon, Diamonds 2015r06 gives following error message Field not found: DiamondsLibrary.SoilSettings.RemovedGroundDivisions with Frm_SoilBasic.TSoilBasicFrame.SetSettings(DiamondsSettings value) with Frm_SoilBasic.TSoilBasicFrame.set_Settings(DiamondsSettings value) with Dlg_AnalysisOptions.TAnalysisOptionsForm.LoadStructuralElements(Double soilhighest) with Dlg_AnalysisOptions.TAnalysisOptionsForm..ctor(Component AOwner, ESelectedAnalysis sa) with MainHelper.TMainHelper.LaunchCalculation(@MetaTMainHelper Self, ESelectedAnalysis sa) Solution Remove Diamonds 2015r06 for the computer Install Diamonds 2015r06…

  • Failed to read from an IPC Port: The pipe has been ended

    On executing elastic analyis, following error message appears: [NL]: Kan niet lezen van een IPC-poort: De pipe is beëindigd. [FR]: Échec de la lecture à partir d’un port IPC: Le canal de communication a été fermé. [ES]: No se pudo leer desde un puerto IPC: Ha terminado la canalización. Solution…

  • ERROR: The type initializer for Dew.Math.Units.MtxVec

    During the elastic analysis Diamonds gives the error ERROR: The type initializer for Dew.Math.Units.MtxVec threw an exception Solution This error can have 2 causes: Diamonds 32-bit is installed on a 64-bit operating system Diamonds 64-bit is installed on a 32-bit operating system Close Diamonds Uninstall Diamonds via Control Panel Check…

  • Error: 1603 Fatal error during installation

    While installing Diamonds or PowerConnect the error pops up Error: 1603 Fatal error during installation Solution This error can have different causes (in order of probability): The SYSTEM account does not have Full Control permissions on the folder that you are trying to install the Windows Installer package to. You…

  • Error message while saving file

    On saving files in Diamonds 2012 r02 following error message appears: ‘Attempted to read or write protected memory. This is often an indication that other memory is corrupt‘ Solution This error message is consequence of a Windows update. Re-install Diamonds as follows: Close Diamonds Go to Windows ‘Control Panel’ >…

  • PowerConnect has stopped working

    The software PowerConnect gives an error message at start-up in Windows 10 ‘PowerConnect has stopped working‘. Solution Reinstall the CodeMeter software: Open the CodeMeter Control Center  (also via ‘Start’ > ‘All programs’ > ‘CodeMeter’) Menu ‘Process’ > ‘Stop CodeMeter Service’ Uninstall CodeMeter Control Center via Control Panel Restart the computer Install…

  • Diamonds.exe has stopped working

    At start-up of Diamonds, you get the error ‘Diamonds.exe has stopped working‘. [NL]: Diamonds werkt niet meer [FR]: Diamonds à cessé de fonctionner [ES]: Diamonds dejó de funcionar Solution 1 Reset the Diamonds preferences. Solution 2 Install a local printer. Solution 3 If your computer recently did updates: Open the CodeMeter Control Center …

  • Zoom in function does not go further

    Zooming in on the Diamonds model does not go any further. More zooming in is not possible. Solution The zoom feature in Diamonds is obviously finite, but here are some tips to run it more smoothly: Check the coordinates of the points in the model. If the structure is positioned…