{"id":4763,"date":"2019-10-29T16:03:30","date_gmt":"2019-10-29T16:03:30","guid":{"rendered":"http:\/\/buildsoftsupport.com\/?post_type=ht_kb&#038;p=4763"},"modified":"2019-12-23T10:21:12","modified_gmt":"2019-12-23T10:21:12","slug":"how-to-change-the-reinforcement-bar-grade","status":"publish","type":"ht_kb","link":"https:\/\/support.buildsoft.eu\/nl\/knowledge-base\/how-to-change-the-reinforcement-bar-grade\/","title":{"rendered":"How to change the reinforcement steel grade"},"content":{"rendered":"<p>For example: change the yielding strenght of the reinforcement belonging to the concrete grade C25\/30.<\/p>\n<ul>\n<li>Open Diamonds<\/li>\n<li>Go to\u00a0<strong>Edit &gt; Section library<\/strong><\/li>\n<li>Find &#8216;Concrete C25\/30&#8217; in the list.<\/li>\n<li>Hit\u00a0<img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-3175\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2018\/07\/ButtonCopy.jpg\" alt=\"\" width=\"24\" height=\"25\" \/>\u00a0to copy the material.<\/li>\n<li>Select the copied material.<\/li>\n<li>Select the relevant standard from the list.<br \/>\n&#8216;Default&#8217; referres to Eurocode without national annex. Same standards (and national annexes) follow Eurocode without national annex, some don&#8217;t.<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-4774\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2019\/10\/ReinforcementGrade1-1024x666.png\" alt=\"\" width=\"643\" height=\"418\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/10\/ReinforcementGrade1-1024x666.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/10\/ReinforcementGrade1-300x195.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/10\/ReinforcementGrade1-768x500.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/10\/ReinforcementGrade1-50x33.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/10\/ReinforcementGrade1-60x39.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/10\/ReinforcementGrade1-35x23.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/10\/ReinforcementGrade1.png 1062w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<li>Go to Advanced &gt; Reinforcement.<\/li>\n<li>Change the yielding strength to the desired value.<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-4775\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2019\/10\/ReinforcementGrade2-1024x666.png\" alt=\"\" width=\"643\" height=\"418\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/10\/ReinforcementGrade2-1024x666.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/10\/ReinforcementGrade2-300x195.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/10\/ReinforcementGrade2-768x500.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/10\/ReinforcementGrade2-50x33.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/10\/ReinforcementGrade2-60x39.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/10\/ReinforcementGrade2-35x23.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/10\/ReinforcementGrade2.png 1062w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<li>If you want the adjusted material to be avaible for other projects besides this one, activate the button <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-1025\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/04\/KnopBibliotheek.png\" alt=\"\" width=\"24\" height=\"25\" \/>.<\/li>\n<li>Hit &#8216;OK&#8217; to close the window.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>For example: change the yielding strenght of the reinforcement belonging to the concrete grade C25\/30. Open Diamonds Go to\u00a0Edit &gt; Section library Find &#8216;Concrete C25\/30&#8217; in the list. Hit\u00a0\u00a0to copy the material. Select the copied material. Select the relevant standard from the list. &#8216;Default&#8217; referres to Eurocode without national annex&#8230;.<\/p>\n","protected":false},"author":3,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":[],"ht-kb-category":[68],"ht-kb-tag":[292,296],"_links":{"self":[{"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb\/4763"}],"collection":[{"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/comments?post=4763"}],"version-history":[{"count":3,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb\/4763\/revisions"}],"predecessor-version":[{"id":4925,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb\/4763\/revisions\/4925"}],"wp:attachment":[{"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/media?parent=4763"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb-category?post=4763"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb-tag?post=4763"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}