{"id":3445,"date":"2019-01-07T09:57:28","date_gmt":"2019-01-07T09:57:28","guid":{"rendered":"http:\/\/buildsoftsupport.com\/?post_type=ht_kb&#038;p=3445"},"modified":"2026-03-28T08:41:12","modified_gmt":"2026-03-28T08:41:12","slug":"how-to-do-a-timber-verification","status":"publish","type":"ht_kb","link":"https:\/\/support.buildsoft.eu\/nl\/knowledge-base\/how-to-do-a-timber-verification\/","title":{"rendered":"How to do timber design"},"content":{"rendered":"<p>To assess a structure (whether it is sufficiant or not), the following steps must be followed in sequence:<\/p>\n<ul>\n<li>Schematising the construction<\/li>\n<li>Determining the internal forces and moments (= global analysis)<\/li>\n<li><strong>Checking the cross-sections (= design):<\/strong>\n<ul>\n<li><strong>Strength<\/strong><\/li>\n<li><strong>Stability\u00a0<\/strong><\/li>\n<li><strong>Stiffness<\/strong><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2>In Diamonds<\/h2>\n<ul>\n<li>In the Load groups dialog <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-1779\" src=\"https:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/ButtonLoadGroups.png\" alt=\"\" width=\"36\" height=\"35\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/ButtonLoadGroups.png 36w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/ButtonLoadGroups-35x34.png 35w\" sizes=\"(max-width: 36px) 100vw, 36px\" \/>, define the correct <strong>Service class<\/strong>.<br \/>\nThe Service class is required to determine<a href=\"https:\/\/buildsoftsupport.com\/knowledge-base\/what-is-kmod\/\"> k<sub>mod<\/sub><\/a>.<br \/>\n<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-5773\" src=\"https:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/06\/kmod2.png\" alt=\"\" width=\"979\" height=\"384\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/06\/kmod2.png 979w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/06\/kmod2-300x118.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/06\/kmod2-768x301.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/06\/kmod2-50x20.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/06\/kmod2-60x24.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/06\/kmod2-35x14.png 35w\" sizes=\"(max-width: 979px) 100vw, 979px\" \/><\/li>\n<li>Calculate the internal forces\u00a0(syn. global analysis)\u00a0<kbd>F9<\/kbd> or <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-1546\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/09\/Calculate.png\" alt=\"\" width=\"24\" height=\"26\" \/>.<br \/>\nDecide whether <strong>global<\/strong> <strong>imperfections<\/strong> are necessary or not.<br \/>\nCheck the option to take <strong>the creep into account<\/strong> (<a href=\"https:\/\/support.buildsoft.eu\/knowledge-base\/what-is-kdef\/\" target=\"_blank\" rel=\"noopener\">more info<\/a>).\u00a0<img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-3795 aligncenter\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2019\/01\/TimberCreep.png\" alt=\"\" width=\"594\" height=\"449\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/01\/TimberCreep.png 594w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/01\/TimberCreep-300x227.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/01\/TimberCreep-50x38.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/01\/TimberCreep-60x45.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/01\/TimberCreep-35x26.png 35w\" sizes=\"(max-width: 594px) 100vw, 594px\" \/><\/li>\n<li><a href=\"http:\/\/buildsoftsupport.com\/knowledge-base\/how-to-set-the-buckling-lengths\/\">Set the buckling lengths<\/a>.<br \/>\nDon&#8217;t skip this step! Without the correct buckling lengths the stability results have no meaning.<\/li>\n<li>Select the correct timber standard using the menu <em><strong>Analysis &gt; Timber standard<\/strong>.<\/em><br \/>\nA list with all available standards in Diamonds can be found <a href=\"https:\/\/support.buildsoft.eu\/knowledge-base\/which-codes-standards-are-implemented-in-diamonds\/\" target=\"_blank\" rel=\"noopener\">here<\/a>.<\/li>\n<li>Click on <kbd>F3<\/kbd> or <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-3446\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2018\/08\/ButtonSteelVerificationTimberVerification.jpg\" alt=\"\" width=\"26\" height=\"26\" \/> to start the verification (<a href=\"https:\/\/support.buildsoft.eu\/docs\/diamonds\/steel-and-timber-verification\/check-resistance-and-stability\/\" target=\"_blank\" rel=\"noopener\">more info<\/a><span style=\"color: initial;\">)<\/span>.<br \/>\nThe verification is supported for:<\/p>\n<ul>\n<li>constant cross-sections with shapes:\u00a0 <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone wp-image-4477\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2019\/01\/TimberSections.png\" alt=\"\" width=\"139\" height=\"40\" \/><\/li>\n<li>variable cross-sections with shape:\u00a0<img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone wp-image-4478\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2019\/01\/TimberSections2.png\" alt=\"\" width=\"26\" height=\"40\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/01\/TimberSections2.png 73w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/01\/TimberSections2-32x50.png 32w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/01\/TimberSections2-39x60.png 39w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/01\/TimberSections2-23x35.png 23w\" sizes=\"(max-width: 26px) 100vw, 26px\" \/><\/li>\n<\/ul>\n<p>At the moment it is not possible to do a timber verification on H-shaped cross sections or composed cross-sections (Section Utility).<\/li>\n<li>To view the results, go to the results configuration <img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-18582\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/01\/KnopConfiguratieResultaten.png\" alt=\"\" width=\"20\" height=\"20\" \/>.<\/li>\n<li>Click on <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone wp-image-3455\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2018\/08\/ButtonStabilityStrength.jpg\" alt=\"\" width=\"32\" height=\"30\" \/>.<br \/>\nThe results of the strength check are behing the button <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone wp-image-3456\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2018\/08\/ButtonStrength.jpg\" alt=\"\" width=\"28\" height=\"30\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2018\/08\/ButtonStrength.jpg 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2018\/08\/ButtonStrength-33x35.jpg 33w\" sizes=\"(max-width: 28px) 100vw, 28px\" \/>, for those of the stability check click <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone wp-image-3457\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2018\/08\/ButtonStability.jpg\" alt=\"\" width=\"28\" height=\"30\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2018\/08\/ButtonStability.jpg 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2018\/08\/ButtonStability-33x35.jpg 33w\" sizes=\"(max-width: 28px) 100vw, 28px\" \/>.<br \/>\nThe results of the strength and stability check are displayed as a percentage:<\/p>\n<ul>\n<li>A structure is sufficient for strength, if the percentage is less than 100% for all bars.<\/li>\n<li>A structure is sufficient for stability, if the percentage is less than 100% for all bars.<\/li>\n<\/ul>\n<p>Based on the percentage no judgment can be made on the extent to which a section is sufficient or not. This is because the used formulas are not always linear.<\/li>\n<li>Optionally, optimize the cross-sections.<br \/>\nYou can use the <a href=\"https:\/\/support.buildsoft.eu\/docs\/diamonds\/steel-and-timber-verification\/optimization-strength-and-stability\/\" target=\"_blank\" rel=\"noopener\">Optimization-function<\/a> for this <img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-17510\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2025\/09\/KnopOptimalisatie.png\" alt=\"\" width=\"20\" height=\"20\" \/>, but it might take a few iterations (and thus time).<br \/>\nWe recommend that you change the cross-sections manually to one (or more) size(s) bigger\/smaller depending on the result you had then recalculating the model. Exspecially for experienced engineer, this works faster than the Optimization function.<\/li>\n<li>Don&#8217;t forget to verify the stiffness! <strong>Thus the vertical and horizontal deformation.<br \/>\n<\/strong>Diamonds can calculate <a href=\"https:\/\/support.buildsoft.eu\/knowledge-base\/how-to-request-the-relative-deflection\/\" target=\"_blank\" rel=\"noopener\">the relative deformation<\/a>, but it&#8217;s still up to you to verify it.<br \/>\nA structure is sufficient if the strength, stability and stiffness are sufficient.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>To assess a structure (whether it is sufficiant or not), the following steps must be followed in sequence: Schematising the construction Determining the internal forces and moments (= global analysis) Checking the cross-sections (= design): Strength Stability\u00a0 Stiffness In Diamonds In the Load groups dialog , define the correct Service&#8230;<\/p>\n","protected":false},"author":3,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":[],"ht-kb-category":[73],"ht-kb-tag":[448,446,640,637,736,737,447,739,504,659],"_links":{"self":[{"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb\/3445"}],"collection":[{"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/comments?post=3445"}],"version-history":[{"count":3,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb\/3445\/revisions"}],"predecessor-version":[{"id":28304,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb\/3445\/revisions\/28304"}],"wp:attachment":[{"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/media?parent=3445"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb-category?post=3445"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb-tag?post=3445"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}