{"id":1215,"date":"2017-10-03T13:51:53","date_gmt":"2017-10-03T13:51:53","guid":{"rendered":"http:\/\/buildsoftsupport.com\/?post_type=ht_kb&#038;p=1215"},"modified":"2025-09-04T10:20:28","modified_gmt":"2025-09-04T10:20:28","slug":"how-does-the-projection-function-work","status":"publish","type":"ht_kb","link":"https:\/\/support.buildsoft.eu\/nl\/knowledge-base\/how-does-the-projection-function-work\/","title":{"rendered":"How does the Projection function work?"},"content":{"rendered":"<div class=\"su-tabs su-tabs-style-default su-tabs-mobile-stack\" data-active=\"1\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-tabs-nav\"><span class=\"\" data-anchor=\"EN\" data-url=\"\" data-target=\"\" tabindex=\"0\" role=\"button\">EN<\/span><span class=\"\" data-anchor=\"NL\" data-url=\"\" data-target=\"\" tabindex=\"0\" role=\"button\">NL<\/span><span class=\"\" data-anchor=\"FR\" data-url=\"\" data-target=\"\" tabindex=\"0\" role=\"button\">FR<\/span><\/div><div class=\"su-tabs-panes\"><div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"EN\">\n<p>The &#8216;Projection&#8217; function will\u00a0adjust the X and\/or Y and\/or Z &#8211;\u00a0coordinates of the selection to the entered value(s). This function is mainly used to correct inaccuracies in the point coordinates.\u00a0These inaccuracies cause trouble in the plate definition and later in the results.<\/p>\n<h3>How do I\u00a0see\/check if there&#8217;s an inaccuracy in the point coordinates?<\/h3>\n<ul>\n<li>In a 3D view this model looks fine.<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-1595\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/Projection-1024x691.png\" alt=\"\" width=\"643\" height=\"434\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-1024x691.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-300x203.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-768x518.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-50x34.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-60x41.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-35x24.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection.png 1074w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<li>But when zooming in\u00a0a front view, some lines become &#8216;bolt&#8217;. This indicates inaccuracies\u00a0in the point coordinates.<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-1594\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/Projection2-1024x691.png\" alt=\"\" width=\"643\" height=\"434\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-1024x691.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-300x203.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-768x518.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-50x34.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-60x41.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-35x24.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2.png 1074w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<li>For the selected wall (use a selection box to select!!) all X-coordinates should be the same. But in the Data table\u00a0<img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-7853\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/09\/KnopDataTabel.png\" alt=\"\" width=\"20\" height=\"20\" \/>\u00a0you see small differences.<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-1593\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/Projection3-1024x691.png\" alt=\"\" width=\"643\" height=\"434\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-1024x691.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-300x203.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-768x518.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-50x34.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-60x41.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-35x24.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3.png 1074w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<\/ul>\n    \t\t<div class=\"hts-messages hts-messages--info   hts-messages--withicon \" id=\"\" style=\"\">\r\n    \t\t\t    \t\t\t    \t\t\t\t<p>\r\n    \t\t\t\t\tDon&#8217;t forget to request enough\u00a0decimals. Sometimes the difference is not in cm (like in this simple example), but in mm or smaller. You can adjust the number of decimals with &#8216;Options&#8217; &gt; &#8216;Units and decimals&#8217;.     \t\t\t\t<\/p>\r\n    \t\t\t    \t\t\t\r\n    \t\t<\/div><!-- \/.ht-shortcodes-messages -->\r\n    \t\t\n<h3>How do I fix this using the Projection function?<\/h3>\n<ul>\n<li>Copy (<kbd>CTRL<\/kbd>+<kbd>C<\/kbd>) the desired X-coordinate from\u00a0the Data table.<\/li>\n<li>Click on <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-1590\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/KnopProjectie.png\" alt=\"\" width=\"38\" height=\"35\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/KnopProjectie.png 38w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/KnopProjectie-35x32.png 35w\" sizes=\"(max-width: 38px) 100vw, 38px\" \/>.<\/li>\n<li>Click on the third icon to enter an X-coordinate. Paste (<kbd>CTRL<\/kbd>+<kbd>P<\/kbd>) the coordinate.<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-1592\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/Projection4-1024x691.png\" alt=\"\" width=\"643\" height=\"434\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-1024x691.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-300x203.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-768x518.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-50x34.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-60x41.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-35x24.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4.png 1074w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<li>Click &#8216;OK&#8217;. All selected points have the same X-coordinate now.<\/li>\n<li>Repeat this as many times as needed.<\/li>\n<li>Don&#8217;t forget to verify the Y and Z-direction as well! But usually the problem is solved after checking the X- and Z-direction.<\/li>\n<\/ul>\n<\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"NL\">\n<p>De\u00a0&#8216;Projectie&#8217; functie zal de X en\/ of Y en\/ of Z co\u00f6rdinaten van de selectie aanpassen naar de ingevulde waarden. Deze functie wordt voornamelijk gebruikt om onvolmaaktheden in de puntco\u00f6rdinaten te corrigeren. Deze onvolmaaktheden zorgen namelijk voor problemen in de plaat definitie en in een later stadium in de resultaten.<\/p>\n<h3>Hoe kan ik zien\/ controleren of er onvolmaaktheden in de puntco\u00f6rdinaten zitten?<\/h3>\n<ul>\n<li>In een 3D zicht lijkt dit model in orde.<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-1595\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/Projection-1024x691.png\" alt=\"\" width=\"643\" height=\"434\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-1024x691.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-300x203.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-768x518.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-50x34.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-60x41.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-35x24.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection.png 1074w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<li>Maar wanneer je inzoomt op een vooraanzicht, worden sommige lijnen &#8216;vetter&#8217; dan andere. De &#8216;vette&#8217; lijnen wijzen op onvolmaaktheden.<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-1594\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/Projection2-1024x691.png\" alt=\"\" width=\"643\" height=\"434\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-1024x691.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-300x203.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-768x518.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-50x34.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-60x41.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-35x24.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2.png 1074w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<li>Op onderstaande figuur is een wand geselecteerd. Voor deze wand zouden alle X-co\u00f6rdinaten hetzelfde moeten zijn.<br \/>\nSelecteer de wand (gebruik hiervoor een selectiekader!) en open de Data tabel\u00a0<img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-7853\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/09\/KnopDataTabel.png\" alt=\"\" width=\"20\" height=\"20\" \/>\u00a0. In deze data tabel zie je kleine afwijkingen.<br \/>\nSoms moet je zelfs iets meer cijfers na de komma vragen (via menu <em>Opties<\/em> &gt; <em>Eenheden en decimale<\/em>n) om de afwijking te kunnen zien!\u00a0<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-1593\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/Projection3-1024x691.png\" alt=\"\" width=\"643\" height=\"434\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-1024x691.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-300x203.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-768x518.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-50x34.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-60x41.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-35x24.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3.png 1074w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<\/ul>\n<h3>Hoe los ik dit op met behulp van de projectiefunctie?<\/h3>\n<ul>\n<li>Kopieer (<kbd>CTRL<\/kbd>+<kbd>C<\/kbd>) de gewenste X co\u00f6rdinaat uit de Data Tabel\u00a0<img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-7853\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/09\/KnopDataTabel.png\" alt=\"\" width=\"20\" height=\"20\" \/>.<\/li>\n<li>Met de muren geselecteerd, klik op de knop\u00a0<img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-1590\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/KnopProjectie.png\" alt=\"\" width=\"38\" height=\"35\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/KnopProjectie.png 38w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/KnopProjectie-35x32.png 35w\" sizes=\"(max-width: 38px) 100vw, 38px\" \/>.<\/li>\n<li>Klik op het derde icoon. Hier kan je enkel een X co\u00f6rdinaat invullen. Plak\u00a0(<kbd>CTRL<\/kbd>+<kbd>P<\/kbd>) de co\u00f6rdinaat.<br \/>\n<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-1592\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/Projection4-1024x691.png\" alt=\"\" width=\"643\" height=\"434\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-1024x691.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-300x203.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-768x518.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-50x34.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-60x41.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-35x24.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4.png 1074w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<li>Klik op &#8216;OK&#8217;. Alle geselecteerde punten hebben nu dezelfde X-co\u00f6rdinaat.<\/li>\n<li>Herhaal deze werkwijze zo vaak als nodig.<\/li>\n<li>Vergeet niet om ook de co\u00f6rdinaten in de Y en Z-richting op dezelfde manier na te kijken. Maar meestal is het probleem verholpen door de X en Z-co\u00f6rdinaten te corrigeren.<\/li>\n<\/ul>\n<\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"FR\">\n<p>La fonction &#8216;Projection&#8217; ajustera les coordonn\u00e9es X et\/ou Y et\/ou Z de la s\u00e9lection\u00a0vers les valeurs saisies. Cette fonction est principalement utilis\u00e9e pour corriger les impr\u00e9cisions dans les coordonn\u00e9es des points. Ces impr\u00e9cisions causent des probl\u00e8mes dans la d\u00e9finition des plaques et plus tard dans les r\u00e9sultats.<\/p>\n<h3>Comment puis-je voir\/v\u00e9rifier s&#8217;il y a des impr\u00e9cisions\u00a0dans les coordonn\u00e9es des points?<\/h3>\n<ul>\n<li>Dans une vue 3D, ce mod\u00e8le semble bien.<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-1595\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/Projection-1024x691.png\" alt=\"\" width=\"643\" height=\"434\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-1024x691.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-300x203.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-768x518.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-50x34.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-60x41.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection-35x24.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection.png 1074w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<li>Cela indique des impr\u00e9cisions dans les coordonn\u00e9es des points.<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-1594\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/Projection2-1024x691.png\" alt=\"\" width=\"643\" height=\"434\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-1024x691.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-300x203.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-768x518.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-50x34.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-60x41.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2-35x24.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection2.png 1074w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<li>Un mur a \u00e9t\u00e9 s\u00e9lectionn\u00e9 dans la figure ci-dessous. Pour ce mur, toutes les coordonn\u00e9es X doivent \u00eatre identiques.<br \/>\nS\u00e9lectionnez le mur (utilisez un chapiteau pour cela\u00a0!) et ouvrez le tableau de donn\u00e9es <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-7853\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/09\/KnopDataTabel.png\" alt=\"\" width=\"20\" height=\"20\" \/>. Dans ce tableau de donn\u00e9es, vous pouvez voir de petits diff\u00e9rences.<br \/>\nIl faut m\u00eame parfois demander un peu plus de chiffres apr\u00e8s la virgule (via le menu <em>Options<\/em> &gt; <em>Unit\u00e9s et D\u00e9cimales<\/em>) pour voir ces diff\u00e9rences!<br \/>\n<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-1593\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/Projection3-1024x691.png\" alt=\"\" width=\"643\" height=\"434\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-1024x691.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-300x203.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-768x518.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-50x34.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-60x41.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3-35x24.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection3.png 1074w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<\/ul>\n<h3>How do I fix this using the Projection function?<\/h3>\n<ul>\n<li>Copiez\u00a0(<kbd>CTRL<\/kbd>+<kbd>C<\/kbd>) la coordonn\u00e9e X souhait\u00e9e \u00e0 partir de la table de donn\u00e9es\u00a0<img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-7853\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/09\/KnopDataTabel.png\" alt=\"\" width=\"20\" height=\"20\" \/>.<\/li>\n<li>Avec le mur s\u00e9lectionn\u00e9, cliquez sur le bouton<img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-1590\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/KnopProjectie.png\" alt=\"\" width=\"38\" height=\"35\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/KnopProjectie.png 38w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/KnopProjectie-35x32.png 35w\" sizes=\"(max-width: 38px) 100vw, 38px\" \/>.<\/li>\n<li>Cliquez sur la troisi\u00e8me ic\u00f4ne. Ici, vous ne pouvez entrer qu&#8217;une coordonn\u00e9e X. Collez (<kbd>CTRL<\/kbd>+<kbd>P<\/kbd>) la coordonn\u00e9e.<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-1592\" src=\"http:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/10\/Projection4-1024x691.png\" alt=\"\" width=\"643\" height=\"434\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-1024x691.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-300x203.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-768x518.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-50x34.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-60x41.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4-35x24.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2017\/10\/Projection4.png 1074w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<li>Cliquez sur OK&#8217;. Maintenant, tous les points s\u00e9lectionn\u00e9s ont la m\u00eame coordonn\u00e9e X.<\/li>\n<li>R\u00e9p\u00e9tez cette op\u00e9ration autant de fois que n\u00e9cessaire.<\/li>\n<li>N&#8217;oubliez pas de v\u00e9rifier \u00e9galement les directions Y et Z ! Mais g\u00e9n\u00e9ralement, le probl\u00e8me est r\u00e9solu apr\u00e8s avoir v\u00e9rifi\u00e9 les directions X et Z.<\/li>\n<\/ul>\n<\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":[],"ht-kb-category":[59],"ht-kb-tag":[1348],"_links":{"self":[{"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb\/1215"}],"collection":[{"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/comments?post=1215"}],"version-history":[{"count":2,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb\/1215\/revisions"}],"predecessor-version":[{"id":8069,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb\/1215\/revisions\/8069"}],"wp:attachment":[{"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/media?parent=1215"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb-category?post=1215"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/support.buildsoft.eu\/nl\/wp-json\/wp\/v2\/ht-kb-tag?post=1215"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}