{"id":7987,"date":"2022-10-05T09:42:21","date_gmt":"2022-10-05T09:42:21","guid":{"rendered":"https:\/\/support.buildsoft.eu\/?post_type=ht_kb&#038;p=7987"},"modified":"2022-10-05T09:42:21","modified_gmt":"2022-10-05T09:42:21","slug":"practical-reinforcement-seems-to-be-removed","status":"publish","type":"ht_kb","link":"https:\/\/support.buildsoft.eu\/fr\/knowledge-base\/practical-reinforcement-seems-to-be-removed\/","title":{"rendered":"Practical reinforcement seems to be removed"},"content":{"rendered":"<p>Explaining the issue works best with an example:<\/p>\n<ul>\n<li>Consider this frame-like structure in which the plates have a Y-coordinate of 3,0m.<br \/>\n<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-7989\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved1.png\" alt=\"\" width=\"643\" height=\"308\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved1.png 1007w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved1-300x144.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved1-768x368.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved1-50x24.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved1-60x29.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved1-35x17.png 35w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<li>Do the elastic analysis <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-7979\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/ConCreteKnopRekenmachine.png\" alt=\"\" width=\"19\" height=\"18\" \/>and calculate the reinforcement <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-3859\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/01\/ButtonReinforcement.jpg\" alt=\"\" width=\"23\" height=\"23\" \/>.<\/li>\n<li>Select both plates and define some practical reinforcement <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone wp-image-6346\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2021\/02\/KnopPractischeWapening.jpg\" alt=\"\" width=\"20\" height=\"21\" \/>.<br \/>\n<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-7988\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved2-1024x667.png\" alt=\"\" width=\"643\" height=\"419\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved2-1024x667.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved2-300x195.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved2-768x500.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved2-50x33.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved2-60x39.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved2-35x23.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved2.png 1098w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><br \/>\nThis tool allows you to define reinforcement zones that stretch\u00a0over multiple plates. A reinforcement zones, doesn&rsquo;t necessarily be defined within the boundaries of one plate. For that reason, the position of the pratical reinforcement is assigned to a point in the 3D environment, not to a certain plate itself. This method has one down side:<\/li>\n<li>Select the plates (and their boundaries) and move the plate for example 0,3cm up.<br \/>\n<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-7991\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved3.png\" alt=\"\" width=\"643\" height=\"368\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved3.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved3-300x172.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved3-50x29.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved3-60x34.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved3-35x20.png 35w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<li>Redo the elastic analysis<img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-7979\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/ConCreteKnopRekenmachine.png\" alt=\"\" width=\"19\" height=\"18\" \/>, calculate the reinforcement<img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-3859\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2019\/01\/ButtonReinforcement.jpg\" alt=\"\" width=\"23\" height=\"23\" \/>\u00a0and open the practical reinforcement <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone wp-image-6346\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2021\/02\/KnopPractischeWapening.jpg\" alt=\"\" width=\"20\" height=\"21\" \/>.\u00a0The practical reinforcement seems to be removed.<br \/>\n<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-7990\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved4-1024x667.png\" alt=\"\" width=\"643\" height=\"419\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved4-1024x667.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved4-300x195.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved4-768x500.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved4-50x33.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved4-60x39.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved4-35x23.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2022\/10\/PracticalReinforcementRemoved4.png 1098w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/>It&rsquo;s not really removed, it&rsquo;s just on a different level. The practical reinforcement was assigned to a point with a Y coordinate of 3,0m. While the plates now have a\u00a0Y coordinate\u00a0that\u00a0equals 3,3m.<br \/>\nFor that reason, you should be finished editing the height and position of the walls before defining pratical reinforcement.<\/li>\n<\/ul>\n<p>Notes:<\/p>\n<ul>\n<li>If the plates were moved back to Y= 3,0m, the practical reinforcement would be visible again. But at the moment, there&rsquo;s not work around to move the pratical reinforcement together with de relevent surface.<\/li>\n<li>For plates\/floors the Y-coordinate is relevant when defining practical reinforcement. Analogously, the X and Z coordinate are relevant for walls.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Explaining the issue works best with an example: Consider this frame-like structure in which the plates have a Y-coordinate of 3,0m. Do the elastic analysis and calculate the reinforcement . Select both plates and define some practical reinforcement . This tool allows you to define reinforcement zones that stretch\u00a0over multiple&#8230;<\/p>\n","protected":false},"author":3,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":[],"ht-kb-category":[62],"ht-kb-tag":[],"_links":{"self":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb\/7987"}],"collection":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/comments?post=7987"}],"version-history":[{"count":1,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb\/7987\/revisions"}],"predecessor-version":[{"id":7992,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb\/7987\/revisions\/7992"}],"wp:attachment":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/media?parent=7987"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb-category?post=7987"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb-tag?post=7987"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}