{"id":30120,"date":"2021-04-26T13:58:06","date_gmt":"2021-04-26T13:58:06","guid":{"rendered":"https:\/\/support.buildsoft.eu\/knowledge-base\/comment-ajouter-des-couches-de-sol-comment-creer-un-profil-de-couche-de-sol\/"},"modified":"2021-04-26T13:58:06","modified_gmt":"2021-04-26T13:58:06","slug":"comment-ajouter-des-couches-de-sol-comment-creer-un-profil-de-couche-de-sol","status":"publish","type":"ht_kb","link":"https:\/\/support.buildsoft.eu\/fr\/knowledge-base\/comment-ajouter-des-couches-de-sol-comment-creer-un-profil-de-couche-de-sol\/","title":{"rendered":"Comment ajouter des couches de sol, comment cr\u00e9er un profil de couche de sol"},"content":{"rendered":"<h2>Avant de commencer<\/h2>\n<ul>\n<li>Un mod\u00e8le peut comporter plusieurs profils de couches de sol.<br \/>\n\u00c0 lire \u00e9galement : <a href=\"https:\/\/support.buildsoft.eu\/knowledge-base\/how-many-soil-layer-profiles-can-be-taken-into-account\/\" target=\"_blank\" rel=\"noopener\">Combien de profils de couches de sol peut-on prendre en compte ?<\/a><\/li>\n<li>Des couches de sol peuvent \u00eatre mises en place sous une poutre, une dalle ou une plaque.<br \/>\nLes couches de terre ne sont pas destin\u00e9es \u00e0 \u00eatre appliqu\u00e9es sur les murs.<\/li>\n<li>L&rsquo;article ci-dessous explique comment ajouter des couches de sol une \u00e0 une dans Diamonds, mais <a href=\"https:\/\/support.buildsoft.eu\/knowledge-base\/template-soil-layer-import\/\">vous pouvez \u00e9galement importer un profil complet de couches de sol<\/a>.<\/li>\n<\/ul>\n<h2>Comment attribuer un profil de couches de sol ?<\/h2>\n<ol>\n<li>S\u00e9lectionnez les poutres\/dalles sous lesquelles vous souhaitez appliquer des couches de sol, puis cliquez sur \u00ab <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-4178\" src=\"https:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/03\/KnopOndersteuning.png\" alt=\"\" width=\"32\" height=\"31\"\/> \u00bb.<\/li>\n<li>Avec le d\u00e9placement en Y, s\u00e9lectionnez \u00ab <em>Couches<\/em> de <em>sol<\/em> \u00bb puis cliquez sur \u00ab <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-large wp-image-6512\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2021\/04\/ButtonSoil.jpg\" alt=\"\" width=\"20\" height=\"20\"\/> \u00bb.<\/li>\n<li>Ensuite, cliquez sur \u00ab <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-7763\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2021\/04\/KnopToevoegen.png\" alt=\"\" width=\"20\" height=\"20\"\/> \u00bb et configurez les param\u00e8tres g\u00e9n\u00e9raux :\n<ul>\n<li>Vous avez le choix entre le test CTP (fr\u00e9quemment utilis\u00e9 en Belgique et aux Pays-Bas) et le test de M\u00e9nard (utilis\u00e9 en France).<\/li>\n<li>Indiquez la position du niveau de l&rsquo;eau par rapport au niveau initial du sol. Ce param\u00e8tre permet de d\u00e9terminer si Diamonds doit calculer les contraintes du sol en utilisant la densit\u00e9 humide ou la densit\u00e9 s\u00e8che du sol. <a href=\"https:\/\/buildsoftsupport.com\/knowledge-base\/how-to-add-ground-or-water-pressure\/\">Vous devez d\u00e9finir manuellement toute pression d&rsquo;eau et\/ou de sol en tant que charge<\/a>!<\/li>\n<li>Cochez cette case si vous souhaitez que la couche inf\u00e9rieure s&rsquo;\u00e9tende jusqu&rsquo;\u00e0 l&rsquo;infini. Cette option est coch\u00e9e par d\u00e9faut, car elle permet d&rsquo;obtenir une valeur prudente pour le r\u00e8glement.<\/li>\n<\/ul>\n<\/li>\n<li>Cliquez sur \u00ab <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-7763\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2021\/04\/KnopToevoegen.png\" alt=\"\" width=\"20\" height=\"20\"\/> \u00bb pour ajouter une nouvelle couche de sol.<br \/>\nSaisissez les propri\u00e9t\u00e9s d&rsquo;une couche de sol (voir ci-dessous).<br \/>\nSi vos dalles de fondation se trouvent \u00e0 diff\u00e9rents niveaux (coordonn\u00e9e Y), vous devez saisir les couches de sol en commen\u00e7ant par le niveau du sol.<\/li>\n<li>Ajoutez autant de couches de terre que n\u00e9cessaire.<\/li>\n<li>Cliquez sur \u00ab OK \u00bb pour fermer toutes les bo\u00eetes de dialogue.<\/li>\n<li>Cliquez sur \u00ab <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-1546\" src=\"https:\/\/buildsoftsupport.com\/wp-content\/uploads\/2017\/09\/Calculate.png\" alt=\"\" width=\"24\" height=\"26\"\/> \u00bb pour lancer l&rsquo;analyse \u00e9lastique.<br \/>\nDans l&rsquo;onglet \u00ab Sol \u00bb, d\u00e9finissez le load group ou la combinaison de charges de r\u00e9f\u00e9rence sur une combinaison \u00c9LS.<\/p>\n<p>Un tableau pr\u00e9sentant les couches de sol ne convient pas aux calculs par la MEF. Les couches du sol sont donc traduites en fonctions. Chaque n\u0153ud du maillage dans la fondation aura une fonction qui d\u00e9pendra des charges pr\u00e9sentes au niveau de ce n\u0153ud\u2026 C\u2019est pourquoi vous devez choisir une combinaison de r\u00e9f\u00e9rence<br \/>\nLes charges de la combinaison de r\u00e9f\u00e9rence d\u00e9termineront le comportement de la fonction \u00ab sol \u00bb.<br \/>\nDans Diamonds, les fonctions li\u00e9es au sol ne peuvent \u00eatre configur\u00e9es que pour une seule chose : soit comprendre le comportement du sol sous compression, soit comprendre celui du sol sous traction.<br \/>\nPar cons\u00e9quent : si vous avez besoin de d\u00e9terminer le tassement dans des combinaisons comportant principalement des charges verticales vers le bas, vous devez choisir une combinaison de r\u00e9f\u00e9rence comportant principalement des charges verticales. Si votre mod\u00e8le comporte \u00e9galement des combinaisons constitu\u00e9es principalement de charges verticales vers le haut (pression de l&rsquo;eau), vous devez alors refaire le calcul une deuxi\u00e8me fois, en utilisant une combinaison de r\u00e9f\u00e9rence comportant \u00e9galement principalement des charges verticales vers le haut.<br \/>\nSi vous essayez de calculer une combinaison compos\u00e9e principalement de charges verticales ascendantes, \u00e0 partir d&rsquo;une combinaison de r\u00e9f\u00e9rence contenant principalement des charges verticales descendantes, cela peut entra\u00eener des probl\u00e8mes d&rsquo;it\u00e9ration.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-7764\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2021\/04\/SoilLayers.png\" alt=\"\" width=\"580\" height=\"538\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2021\/04\/SoilLayers.png 580w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2021\/04\/SoilLayers-300x278.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2021\/04\/SoilLayers-50x46.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2021\/04\/SoilLayers-60x56.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2021\/04\/SoilLayers-35x32.png 35w\" sizes=\"(max-width: 580px) 100vw, 580px\" \/><\/li>\n<\/ol>\n<div class=\"su-accordion su-u-trim\"><div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-plus su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>Param\u00e8tres du sol pour un essai CPT<\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\nPour r\u00e9aliser un essai de p\u00e9n\u00e9tration au c\u00f4ne (ou CPT), vous devez saisir les donn\u00e9es suivantes :<\/p>\n<ul>\n<li><strong>L&rsquo;\u00e9paisseur de la couche<\/strong><\/li>\n<li><strong>La constante de compressibilit\u00e9 C<\/strong> est g\u00e9n\u00e9ralement indiqu\u00e9e dans la note de calcul CPT.<br \/>\nSinon, on peut le calculer \u00e0 partir de :<\/p>\n<p class=\"ql-center-displayed-equation\" style=\"line-height: 20px;\"><span class=\"ql-right-eqno\"> &nbsp; <\/span><span class=\"ql-left-eqno\"> &nbsp; <\/span><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/ql-cache\/quicklatex.com-010d8faad6c12e6f7c40e78b0b82edfd_l3.png\" height=\"20\" width=\"69\" class=\"ql-img-displayed-equation quicklatex-auto-format\" alt=\"&#92;&#091;&#67;&#32;&#92;&#99;&#100;&#111;&#116;&#32;&#113;&#95;&#99;&#125;&#123;&#92;&#115;&#105;&#103;&#109;&#97;&#39;&#95;&#123;&#118;&#46;&#48;&#125;&#125;&#92;&#093;\" title=\"Rendered by QuickLaTeX.com\"\/><\/p>\n<p>Avec<\/p>\n<ul>\n<li><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/ql-cache\/quicklatex.com-1739e84b65a42bd788f3847ba5f1787b_l3.png\" class=\"ql-img-inline-formula quicklatex-auto-format\" alt=\"&#113;&#95;&#99;\" title=\"Rendered by QuickLaTeX.com\" height=\"12\" width=\"14\" style=\"vertical-align: -4px;\"\/> : la r\u00e9sistance conique<\/li>\n<li><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/ql-cache\/quicklatex.com-976ceff3072efad066e3213913ae18c6_l3.png\" class=\"ql-img-inline-formula quicklatex-auto-format\" alt=\"&#92;&#115;&#105;&#103;&#109;&#97;&#39;&#95;&#123;&#118;&#46;&#48;&#125;\" title=\"Rendered by QuickLaTeX.com\" height=\"19\" width=\"28\" style=\"vertical-align: -5px;\"\/> : la tension granulom\u00e9trique \u00e0 la profondeur <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/ql-cache\/quicklatex.com-2ce27f7d2d82e3b238176ec7e7ee9118_l3.png\" class=\"ql-img-inline-formula quicklatex-auto-format\" alt=\"&#104;\" title=\"Rendered by QuickLaTeX.com\" height=\"12\" width=\"10\" style=\"vertical-align: 0px;\"\/><\/li>\n<li>Facteur de corr\u00e9lation <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/ql-cache\/quicklatex.com-5f44d9bbc8046069be4aa2989bff19aa_l3.png\" class=\"ql-img-inline-formula quicklatex-auto-format\" alt=\"&#92;&#97;&#108;&#112;&#104;&#97;\" title=\"Rendered by QuickLaTeX.com\" height=\"8\" width=\"11\" style=\"vertical-align: 0px;\"\/> (voir EN 1997-1-2, tableau D.2)<\/li>\n<\/ul>\n<\/li>\n<li><strong>La constante de recompressibilit\u00e9 A<\/strong> peut \u00eatre calcul\u00e9e \u00e0 partir de C, en fonction du type de sol<br \/>\n(source : \u00ab D\u00e9termination de la compressibilit\u00e9 \u00e0 partir d&rsquo;essais in situ \u00bb \u2013 KVIV-TI)<\/p>\n<ul>\n<li>Sable : A = 8 \u00e0 10 x C<\/li>\n<li>Terre limoneuse : A = 4 \u00e0 5 x C<\/li>\n<li>Argile : A = 3 \u00d7 C<\/li>\n<li>Tourbe : A = C<\/li>\n<\/ul>\n<\/li>\n<li><strong>Le taux de drainage CC<\/strong> [%]\nCette valeur permet de mesurer l&rsquo;ampleur du tassement (rel\u00e2chement) qui s&rsquo;est produit entre le moment de l&rsquo;excavation et celui du (re)chargement.<\/p>\n<ul>\n<li>CC = 0 %<br \/>\nLes travaux d&rsquo;excavation et de chargement r\u00e9alis\u00e9s par l&rsquo;entreprise de fondations s&rsquo;encha\u00eenent rapidement. Il n&rsquo;est pas possible de laisser le sol se tasser. Au niveau des fondations, la contrainte du sol est \u00e9gale \u00e0 la contrainte g\u00e9ostatique initiale.<\/li>\n<li>CC = 100 % (valeur par d\u00e9faut)<br \/>\nIl s&rsquo;\u00e9coule un long d\u00e9lai entre les travaux d&rsquo;excavation et le chargement par la fondation, ce qui entra\u00eene la disparition progressive de toute pr\u00e9-consolidation. Au niveau des fondations, la contrainte du sol est \u00e9gale \u00e0 0 kN\/m et elle se comportera comme la surface naturelle du sol.<br \/>\nIl en r\u00e9sulte des ajustements plus importants (plus prudents) que lorsque CC = 0 %. Plus <a href=\"https:\/\/buildsoftsupport.com\/knowledge-base\/how-to-take-an-excavation-into-account\/\">d&rsquo;informations ici.<\/a><\/li>\n<\/ul>\n<p>Le temps de compactage ne d\u00e9pend pas uniquement du d\u00e9lai entre l&rsquo;excavation et le chargement, mais \u00e9galement du type de sol, et plus particuli\u00e8rement de sa capacit\u00e9 de drainage. Plus un sol est capable d&rsquo;\u00e9vacuer facilement l&rsquo;eau interstitielle, plus vite il se d\u00e9tendra et plus rapidement la pr\u00e9-consolidation dispara\u00eetra.<\/p>\n<ul>\n<li>Pour une fosse de fondation en cours de drainage, le CC sera de 100 %.<\/li>\n<li>Le sable se draine bien, donc le CC sera d&rsquo;environ 100 %.<\/li>\n<li>Les couches sup\u00e9rieures d&rsquo;argile, de faible \u00e9paisseur, se draineront assez rapidement ; le CC se situera donc entre 50 et 75 %.<\/li>\n<li>Les couches inf\u00e9rieures d&rsquo;argile \u00e9paisses se draineront assez lentement ; la capacit\u00e9 de r\u00e9tention d&rsquo;eau (CC) se situera donc entre 25 et 50 %.<\/li>\n<li>Les couches d&rsquo;argile \u00e9paisses et profondes se drainent lentement ; le CC se situera donc entre 0 et 25 %.<\/li>\n<\/ul>\n<p>Dans la pratique, ce sont les valeurs de 0 % et 100 % qui sont le plus souvent utilis\u00e9es.<\/li>\n<li><strong>Le taux de surconsolidation (OCR<\/strong> ) tient compte de la pr\u00e9charge, qui diff\u00e8re d&rsquo;une excavation. Par exemple : un ancien b\u00e2timent sera d\u00e9moli avant la construction d&rsquo;un nouveau. Ou bien, un important tas de terre (au-dessus du niveau du sol) sera \u00e9vacu\u00e9 avant le d\u00e9but des travaux.<br \/>\nL&rsquo;ancien b\u00e2timent et le tas de terre constituent une pr\u00e9charge du sol qui ne peut \u00eatre consid\u00e9r\u00e9e comme une excavation. Pour cela, vous devrez augmenter la valeur OCR.<\/li>\n<\/ul>\n<\/div><\/div>\n<div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-plus su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span>Param\u00e8tres du sol pour un essai de M\u00e9nard<\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">\nUn essai au pressom\u00e8tre fournit \u00e9galement les param\u00e8tres du sol n\u00e9cessaires au calcul du tassement \u00e0 l&rsquo;aide d&rsquo;une m\u00e9thode it\u00e9rative.<br \/>\nCet essai est r\u00e9alis\u00e9 \u00e0 l&rsquo;aide d&rsquo;un cylindre expansible. Il est soit plac\u00e9 directement dans un trou pr\u00e9-for\u00e9, soit amen\u00e9 \u00e0 la profondeur souhait\u00e9e par autoforage, enfoncement, vibration ou tout autre proc\u00e9d\u00e9 appropri\u00e9. Les mesures des d\u00e9formations du sol, bas\u00e9es sur les pressions exerc\u00e9es sur la t\u00eate de sondage, vous permettent de repr\u00e9senter graphiquement les d\u00e9formations en fonction des forces exerc\u00e9es et d&rsquo;en d\u00e9duire les caract\u00e9ristiques m\u00e9caniques du sol.<br \/>\nLe module de compression pressurem\u00e9trique EMK ainsi d\u00e9termin\u00e9 \u00e0 diff\u00e9rentes profondeurs est parfaitement analogue \u00e0 la constante de compression C. Les tassements sont d\u00e9termin\u00e9s selon la loi de Terzaghi, mais \u00e0 l&rsquo;aide de l&rsquo;\u00e9quation suivante :<\/p>\n<p class=\"ql-center-displayed-equation\" style=\"line-height: 40px;\"><span class=\"ql-right-eqno\"> &nbsp; <\/span><span class=\"ql-left-eqno\"> &nbsp; <\/span><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/ql-cache\/quicklatex.com-ed8de20aafb5152b5a594130cea4d604_l3.png\" height=\"40\" width=\"206\" class=\"ql-img-displayed-equation quicklatex-auto-format\" alt=\"&#92;&#091;&#115;&#40;&#105;&#41;&#61;&#92;&#115;&#117;&#109;&#32;&#92;&#102;&#114;&#97;&#99;&#123;&#92;&#97;&#108;&#112;&#104;&#97;&#32;&#95;&#123;&#107;&#125;&#92;&#99;&#100;&#111;&#116;&#32;&#92;&#68;&#101;&#108;&#116;&#97;&#32;&#104;&#125;&#123;&#69;&#95;&#123;&#77;&#75;&#125;&#125;&#92;&#99;&#100;&#111;&#116;&#32;&#92;&#68;&#101;&#108;&#116;&#97;&#32;&#92;&#115;&#105;&#103;&#109;&#97;&#32;&#95;&#123;&#122;&#125;&#40;&#105;&#41;&#92;&#093;\" title=\"Rendered by QuickLaTeX.com\"\/><\/p>\n<p>Dans cette formule, \u0394\u03c3z(i) correspond \u00e0 la contrainte de traction verticale r\u00e9sultant des charges sup\u00e9rieures et observ\u00e9e au point i situ\u00e9 \u00e0 la profondeur z. \u0394h correspond \u00e0 l&rsquo;\u00e9paisseur d&rsquo;une couche du sol en question.<br \/>\nLe coefficient \u03b1k d\u00e9pend de la nature du sol et peut \u00eatre consult\u00e9 dans le tableau ci-dessous :<\/p>\n<table align=\"center\">\n<tbody>\n<tr>\n<td>Nature du sol<\/td>\n<td>Tourbe<\/td>\n<td>Argile<\/td>\n<td>Sol calcaire<\/td>\n<td>Sable<\/td>\n<td>Gravier<\/td>\n<\/tr>\n<tr>\n<td>Tr\u00e8s compact<\/td>\n<td style=\"text-align: center;\">&#8211;<\/td>\n<td style=\"text-align: center;\">1<\/td>\n<td style=\"text-align: center;\">2\/3<\/td>\n<td style=\"text-align: center;\">1\/2<\/td>\n<td style=\"text-align: center;\">1\/3<\/td>\n<\/tr>\n<tr>\n<td>Compact\u00e9 de mani\u00e8re normale<\/td>\n<td style=\"text-align: center;\">1<\/td>\n<td style=\"text-align: center;\">2\/3<\/td>\n<td style=\"text-align: center;\">1\/2<\/td>\n<td style=\"text-align: center;\">1\/3<\/td>\n<td style=\"text-align: center;\">1\/4<\/td>\n<\/tr>\n<tr>\n<td>Non compact\u00e9<\/td>\n<td style=\"text-align: center;\">&#8211;<\/td>\n<td style=\"text-align: center;\">1\/2<\/td>\n<td style=\"text-align: center;\">1\/2<\/td>\n<td style=\"text-align: center;\">1\/3<\/td>\n<td style=\"text-align: center;\">1\/4<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Avant de commencer Un mod\u00e8le peut comporter plusieurs profils de couches de sol. \u00c0 lire \u00e9galement : Combien de profils de couches de sol peut-on prendre en compte ? Des couches de sol peuvent \u00eatre mises en place sous une poutre, une dalle ou une plaque. Les couches de terre&#8230;<\/p>\n","protected":false},"author":3,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":[],"ht-kb-category":[1274],"ht-kb-tag":[1277,119,814,875,787,148,117,169,1218],"_links":{"self":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb\/30120"}],"collection":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/comments?post=30120"}],"version-history":[{"count":0,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb\/30120\/revisions"}],"wp:attachment":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/media?parent=30120"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb-category?post=30120"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb-tag?post=30120"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}