{"id":12730,"date":"2024-04-05T13:08:48","date_gmt":"2024-04-05T13:08:48","guid":{"rendered":"https:\/\/support.buildsoft.eu\/?post_type=ht_kb&#038;p=12730"},"modified":"2024-04-05T13:08:48","modified_gmt":"2024-04-05T13:08:48","slug":"from-powerconnect-to-idea-statica-connection","status":"publish","type":"ht_kb","link":"https:\/\/support.buildsoft.eu\/fr\/knowledge-base\/from-powerconnect-to-idea-statica-connection\/","title":{"rendered":"From PowerConnect to Idea StatiCa Connection"},"content":{"rendered":"\n<p>This article explains how to send one or more PowerConnect connections to Idea Statica Connection, using BIM Expert.<\/p>\n\n\n\n<!--more-->\n\n\n\n<figure class=\"wp-block-embed aligncenter is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"PowerConnect to Idea StatiCa Connection with BIM Expert\" width=\"1200\" height=\"675\" src=\"https:\/\/www.youtube.com\/embed\/PQlx8bSWggA?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"1-preparation-in-revit\"><strong>1. Preparation in PowerConnect<\/strong><\/h2>\n\n\n\n<p>Make sure the connections have a unique name.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"2-send-the-revit-model-to-tekla-structures\"><strong>2. Send the PowerConnect model to Idea StatiCa Connection<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2-1-from-revit-to-bim-expert\">2.1 From PowerConnect to BIM Expert<\/h3>\n\n\nIn the File menu tab, select \u2018Export &gt; Export to BIM Expert\u2019\u00a0 or simply use F8.\r\n\r\n<img decoding=\"async\" loading=\"lazy\" class=\"wp-image-9471 aligncenter\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_importfrompc_tobe.png\" alt=\"\" width=\"328\" height=\"194\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_importfrompc_tobe.png 495w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_importfrompc_tobe-300x178.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_importfrompc_tobe-50x30.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_importfrompc_tobe-60x36.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_importfrompc_tobe-35x21.png 35w\" sizes=\"(max-width: 328px) 100vw, 328px\" \/>\r\n\r\nThe (physical) connection models will sent to BIM Expert. All sections, material, stiffeners, bolts and welds are automatically converted and transferred. The connections are now in BIM Expert.\r\n\r\n    \t\t<div class=\"hts-messages hts-messages--alert  hts-messages--withtitle hts-messages--withicon \" id=\"\" style=\"\">\r\n    \t\t\t<span class=\"hts-messages__title\">Attention: no loads conversion<\/span>    \t\t\t    \t\t\t\t<p>\r\n    \t\t\t\t\tLoads as defined in PowerConnect will not be transferred to BIM Expert.    \t\t\t\t<\/p>\r\n    \t\t\t    \t\t\t\r\n    \t\t<\/div><!-- \/.ht-shortcodes-messages -->\r\n    \t\t\r\n<div id=\"ConnectiveDocSignExtentionInstalled\" data-extension-version=\"1.0.4\"><\/div>\r\n<script src=\"moz-extension:\/\/ccccaaeb-013b-4b99-be98-cffa5aa77072\/js\/app.js\" type=\"text\/javascript\"><\/script>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2-2-from-bim-expert-to-tekla-structures\">2.2 From BIM Expert to Idea StatiCa Connection<\/h3>\n\n\n<p>In the Model tab, select \u2018Export\u2019. Next, choose the destination software, namely Idea StatiCa. Click\u00a0<img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone wp-image-9082\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/04\/bimexpert_totekla_arrow.png\" sizes=\"(max-width: 29px) 100vw, 29px\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/04\/bimexpert_totekla_arrow.png 43w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/04\/bimexpert_totekla_arrow-35x33.png 35w\" alt=\"\" width=\"29\" height=\"28\" \/> to continue.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-9116 aligncenter\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea.png\" alt=\"\" width=\"366\" height=\"222\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea.png 602w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea-300x182.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea-50x30.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea-60x36.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea-35x21.png 35w\" sizes=\"(max-width: 366px) 100vw, 366px\" \/><\/p>\n<h4 id=\"2-2-1-settings\">2.2.1 Settings<\/h4>\n<h5>2.2.1.1 Version<\/h5>\n<p>Select the desired version of Idea StatiCa.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-9155 aligncenter\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_version.png\" alt=\"\" width=\"289\" height=\"157\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_version.png 378w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_version-300x163.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_version-50x27.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_version-60x33.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_version-35x19.png 35w\" sizes=\"(max-width: 289px) 100vw, 289px\" \/><\/p>\n<h5>2.2.1.2 Model type<\/h5>\n<p>Choose between model types analysis or physical:<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-9154 aligncenter\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_modelchoice.png\" alt=\"\" width=\"674\" height=\"160\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_modelchoice.png 964w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_modelchoice-300x71.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_modelchoice-768x182.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_modelchoice-50x12.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_modelchoice-60x14.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_modelchoice-35x8.png 35w\" sizes=\"(max-width: 674px) 100vw, 674px\" \/><\/p>\n<ul>\n<li>The <strong>analysis model<\/strong> will only send independent analytical bars, as defined in the analytical model:\n<ul>\n<li>When bars are continuous in reality and grouped into a physical group, this is ignored.<\/li>\n<li>Existing connections (e.g. from Tekla Structures, Revit or PowerConnect) are also ignored. Only the analysis members will remain. All physical elements (bolts, welds, connection plates, &#8230; ) will be ignored in the transfer.<\/li>\n<\/ul>\n<\/li>\n<li>The <strong>physical model<\/strong> will send physical elements, that is\n<ul>\n<li>Continuous bars (if properly grouped)<\/li>\n<li>Connections including all physical elements (bolts, welds, connection plates, &#8230; ). Connections are always in the physical model defined.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>If you choose physical model, it is recommended to opt for &lsquo;Use data from analysis model&rsquo;, as this will use the load and result information from the analysis model.<\/p>\n<p>It is good practice to check &lsquo;Export loads&rsquo; and Export results&rsquo; unless you want to define the loads again in Idea StatiCa Connection.<\/p>\n<h5>2.2.1.3 Destination<\/h5>\n<p>Select the destination &lsquo;Idea StatiCa Connection&rsquo;.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-9153 aligncenter\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_destination.png\" alt=\"\" width=\"356\" height=\"161\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_destination.png 506w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_destination-300x136.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_destination-50x23.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_destination-60x27.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_exporttoidea_destination-35x16.png 35w\" sizes=\"(max-width: 356px) 100vw, 356px\" \/><\/p>\n<h4>2.2.2 Select nodes and connections<\/h4>\n<p>In the next window you get an overview of the model, where nodes and connections can be selected to be transferred.\u00a0On the left side, &lsquo;Connections in Idea StatiCa&rsquo; holds a list with all connections to be sent to Idea. The list is empty by default.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-9158 aligncenter\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical.png\" alt=\"\" width=\"723\" height=\"341\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical.png 1573w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical-300x142.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical-768x362.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical-1024x483.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical-50x24.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical-60x28.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical-35x17.png 35w\" sizes=\"(max-width: 723px) 100vw, 723px\" \/><\/p>\n<p>Depending on the choice of model (analysis or physical) and whether there are physical connections present in the model, this window can have different layouts.<\/p>\n<p><div class=\"su-tabs su-tabs-style-default su-tabs-mobile-stack\" data-active=\"1\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-tabs-nav\"><span class=\"\" data-anchor=\"no\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">Analysis model<\/span><span class=\"\" data-url=\"\" data-target=\"blank\" tabindex=\"0\" role=\"button\">Physical model<\/span><\/div><div class=\"su-tabs-panes\"><div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"Analysis model\"><\/p>\n<p>You will see the analysis &lsquo;bar&rsquo; model, with square nodes at the intersection points. If there are physical connections present in the model, you will also see the physical model and a list of recognized connections.<\/p>\n<p>Click on a node in the Analysis model to select all connected bars (shown in red) and hit &lsquo;Add selection&rsquo; to add them to the list.\u00a0 Already added nodes will be displayed in blue.<\/p>\n<p>If physical connections are present, you can also select these nodes from the physical model, but only the ones that are already defined in the list. When you select a node, the physical model will zoom to the selected item.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-9127 aligncenter\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical_pa.png\" alt=\"\" width=\"738\" height=\"346\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical_pa.png 1697w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical_pa-300x141.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical_pa-768x360.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical_pa-1024x480.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical_pa-50x23.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical_pa-60x28.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_analytical_pa-35x16.png 35w\" sizes=\"(max-width: 738px) 100vw, 738px\" \/><\/p>\n<p>    \t\t<div class=\"hts-messages hts-messages--alert  hts-messages--withtitle hts-messages--withicon \" id=\"\" style=\"\">\r\n    \t\t\t<span class=\"hts-messages__title\">Attention<\/span>    \t\t\t    \t\t\t\t<p>\r\n    \t\t\t\t\tIf you selected the &lsquo;Analytical model transfer&rsquo;, all physical elements (bolts, welds, connection plates, &#8230; ) will be ignored in the transfer. Only analysis bars will be sent &#8211; even for physical nodes. That means that all connection elements (e.g. bolts, welds, plates, ..) must be redefined in Idea StatiCa Connection.     \t\t\t\t<\/p>\r\n    \t\t\t    \t\t\t\r\n    \t\t<\/div><!-- \/.ht-shortcodes-messages -->\r\n    \t\t<\/p>\n<p><\/div>\n<div class=\"su-tabs-pane su-u-clearfix su-u-trim\" data-title=\"Physical model\"><\/p>\n<p>You see will the physical model, with all cross-section drawn.<\/p>\n<p>Add a connection by either:<\/p>\n<ul>\n<li>Selecting one or more existing physical connections from the list and click &lsquo;Add selected&rsquo;<\/li>\n<li>Selecting an existing physical connection from model, by clicking one the connection part (e.g. haunch, end plate, bolts, &#8230; ) and click &lsquo;Add selection&rsquo;. The whole connection will be highlighted in red.<\/li>\n<li>Selecting multiple physical bars:\n<ul>\n<li>First click on an empty white space to ensure nothing is selected<\/li>\n<li>Select physical bars (highlighted in red) and click &lsquo;Add selection&rsquo;<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter wp-image-9135 \" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_physical_p.png\" alt=\"\" width=\"857\" height=\"399\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_physical_p.png 1695w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_physical_p-300x140.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_physical_p-768x357.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_physical_p-1024x477.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_physical_p-50x23.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_physical_p-60x28.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_physical_p-35x16.png 35w\" sizes=\"(max-width: 857px) 100vw, 857px\" \/><\/p>\n<p><\/div><\/div><\/div><\/p>\n<p>Hit \u2018Continue\u2019 to continue the transfer to Idea StatiCa.<\/p>\n<h4 id=\"2-2-2-material-mapping\">2.2.3 Saving the model<\/h4>\n<p>Choose a folder to save the conversion files (IOM etc).\u00a0 We recommend to have a separate BIM Expert folder, where all your models are stored.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\" wp-image-9124 aligncenter\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toideafilebrowser.png\" alt=\"\" width=\"273\" height=\"288\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toideafilebrowser.png 373w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toideafilebrowser-285x300.png 285w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toideafilebrowser-47x50.png 47w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toideafilebrowser-57x60.png 57w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toideafilebrowser-33x35.png 33w\" sizes=\"(max-width: 273px) 100vw, 273px\" \/><\/p>\n<h4 id=\"2-2-2-section-mapping\">2.2.4 Open the model in Idea Checkbot<\/h4>\n<p>Idea Checkbot will launch automatically.\u00a0 A &lsquo;New&rsquo; tab, a new project is proposed and the project name and project folder are filled out accordingly. Click &lsquo;Create project&rsquo; to start.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-9120 aligncenter\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_newproject.png\" alt=\"\" width=\"448\" height=\"233\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_newproject.png 734w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_newproject-300x156.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_newproject-50x26.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_newproject-60x31.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_newproject-35x18.png 35w\" sizes=\"(max-width: 448px) 100vw, 448px\" \/><\/p>\n<h4 id=\"2-2-2-section-mapping\">2.2.5 Load the nodes<\/h4>\n<p>Click &lsquo;Import &gt; Bulk&rsquo; to load all nodes. Depending on the number of nodes selected and the amount of results in model, this can take a while.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\" wp-image-9121 aligncenter\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_importbulk.png\" alt=\"\" width=\"78\" height=\"86\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_importbulk.png 103w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_importbulk-45x50.png 45w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_importbulk-54x60.png 54w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_importbulk-32x35.png 32w\" sizes=\"(max-width: 78px) 100vw, 78px\" \/><\/p>\n<p>Select a connection from the list of project items and click &lsquo;Open&rsquo; to open it in Idea StatiCa Connection.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-9122 aligncenter\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_listandopen.png\" alt=\"\" width=\"605\" height=\"206\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_listandopen.png 866w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_listandopen-300x102.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_listandopen-768x262.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_listandopen-50x17.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_listandopen-60x20.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/05\/bimexpert_toidea_listandopen-35x12.png 35w\" sizes=\"(max-width: 605px) 100vw, 605px\" \/><\/p>\n<p><script src=\"moz-extension:\/\/ccccaaeb-013b-4b99-be98-cffa5aa77072\/js\/app.js\" type=\"text\/javascript\"><\/script><\/p>\n<p><script src=\"moz-extension:\/\/ccccaaeb-013b-4b99-be98-cffa5aa77072\/js\/app.js\" type=\"text\/javascript\"><\/script><\/p>\n<p><script src=\"moz-extension:\/\/ccccaaeb-013b-4b99-be98-cffa5aa77072\/js\/app.js\" type=\"text\/javascript\"><\/script><\/p>\n<div id=\"ConnectiveDocSignExtentionInstalled\" data-extension-version=\"1.0.4\"><\/div>\n\n\n\n\n<h2 class=\"wp-block-heading\" id=\"3-final-steps-in-tekla-structures\"><strong>3. Final steps in Idea StatiCa Connection<\/strong><\/h2>\n\n\n\n<p>You will see the already defined connections. You need to add the loads before running analysis in Idea StatiCa Connection.<\/p>\n\n\n\n<div>\n<h2 id=\"1-preparation-in-revit\" class=\"wp-block-heading\"><strong>4. Get started with BIM Expert<br \/>\n<\/strong><\/h2>\n<\/div>\n<div style=\"text-align: left;\"><div class=\"su-button-center\"><a href=\"https:\/\/support.buildsoft.eu\" class=\"su-button su-button-style-flat\" style=\"color:#FFFFFF;background-color:#E74C3C;border-color:#b93d30;border-radius:0px\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"color:#FFFFFF;padding:8px 26px;font-size:20px;line-height:30px;border-color:#ef8277;border-radius:0px;text-shadow:none\"><i class=\"sui sui-arrow-right\" style=\"font-size:20px;color:#FFFFFF\"><\/i> Download your free trial of BIM Expert<\/span><\/a><\/div><\/div>\n<div><div class=\"su-spacer\" style=\"height:75px\"><\/div><\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>This article explains how to send one or more PowerConnect connections to Idea Statica Connection, using BIM Expert.<\/p>\n","protected":false},"author":2,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":[],"ht-kb-category":[1141,1261],"ht-kb-tag":[],"_links":{"self":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb\/12730"}],"collection":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/comments?post=12730"}],"version-history":[{"count":2,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb\/12730\/revisions"}],"predecessor-version":[{"id":12742,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb\/12730\/revisions\/12742"}],"wp:attachment":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/media?parent=12730"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb-category?post=12730"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb-tag?post=12730"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}