{"id":11047,"date":"2023-11-22T15:08:56","date_gmt":"2023-11-22T15:08:56","guid":{"rendered":"https:\/\/support.buildsoft.eu\/?post_type=ht_kb&#038;p=11047"},"modified":"2024-01-25T09:33:29","modified_gmt":"2024-01-25T09:33:29","slug":"how-to-show-anchorage-length-in-the-practical-reinforcement","status":"publish","type":"ht_kb","link":"https:\/\/support.buildsoft.eu\/fr\/knowledge-base\/how-to-show-anchorage-length-in-the-practical-reinforcement\/","title":{"rendered":"How to show anchorage length in the practical reinforcement?"},"content":{"rendered":"[This feature is available in Diamonds 2024 or newer]\n<p>To show the anchorage length on the screen:<\/p>\n<ul>\n<li>Select the relevant plates and open the practical reinforcement module <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-6346\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2021\/02\/KnopPractischeWapening.jpg\" alt=\"\" width=\"30\" height=\"31\">.<\/li>\n<li>Open the configuration settings <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-10069\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2018\/07\/KnopConfiguratieInstellingen.png\" alt=\"\" width=\"20\" height=\"20\"> and go to the tab-page &lsquo;Reinforcement&rsquo;.<br \/>\nCheck the option &lsquo;Show anchorage length&rsquo; and set the desired length (X times diameter of the bars).<br \/>\nHit &lsquo;OK&rsquo; to close the dialogue.<br \/>\n<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-11049\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings.png\" alt=\"\" width=\"652\" height=\"507\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings.png 652w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings-300x233.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings-50x39.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings-60x47.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings-35x27.png 35w\" sizes=\"(max-width: 652px) 100vw, 652px\" \/><\/li>\n<li>Result: zones with reinforcement <strong>bars<\/strong> will get an offset in the relevant direction. The offset does not count in the cracked deformation (therefore it&rsquo;s not drawn white).<br \/>\nZones with reinforcement <strong>nets<\/strong>&nbsp;will NOT get an offset.<br \/>\n<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-large wp-image-11050\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings2-1024x689.png\" alt=\"\" width=\"643\" height=\"433\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings2-1024x689.png 1024w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings2-300x202.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings2-768x517.png 768w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings2-50x34.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings2-60x40.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings2-35x24.png 35w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings2.png 1258w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/li>\n<\/ul>\n<p>If you choose not to show the anchor lengths on the screen (for example because they are in the way), you can still easily include them in the DXF export (see the procedure below).<\/p>\n<h2>To include the anchorage length in an export<\/h2>\n<ul>\n<li>Select the relevant plates and open the practical reinforcement module <img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-6346\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2021\/02\/KnopPractischeWapening.jpg\" alt=\"\" width=\"30\" height=\"31\">.<\/li>\n<li>Go to File &gt; Export to DXF. A pop-up dialogue will ask you if you want the include the anchorage length (for the zones with reinforcement bars) or not.<br \/>\n<img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-11051\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings3.png\" alt=\"\" width=\"322\" height=\"147\" srcset=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings3.png 322w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings3-300x137.png 300w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings3-50x23.png 50w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings3-60x27.png 60w, https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2023\/11\/PracticalReinforcementConfigurationSettings3-35x16.png 35w\" sizes=\"(max-width: 322px) 100vw, 322px\" \/><\/li>\n<\/ul>\n<p>Note: a PDF export always prints what you see, so if you want to include the anchorage length in a pdf, you should make it visible using the configuration settings <img decoding=\"async\" loading=\"lazy\" class=\"img_inline alignnone size-full wp-image-10069\" src=\"https:\/\/support.buildsoft.eu\/wp-content\/uploads\/2018\/07\/KnopConfiguratieInstellingen.png\" alt=\"\" width=\"20\" height=\"20\">.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[This feature is available in Diamonds 2024 or newer] To show the anchorage length on the screen: Select the relevant plates and open the practical reinforcement module . Open the configuration settings and go to the tab-page &lsquo;Reinforcement&rsquo;. Check the option &lsquo;Show anchorage length&rsquo; and set the desired length (X&#8230;<\/p>\n","protected":false},"author":3,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":[],"ht-kb-category":[68],"ht-kb-tag":[],"_links":{"self":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb\/11047"}],"collection":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/comments?post=11047"}],"version-history":[{"count":3,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb\/11047\/revisions"}],"predecessor-version":[{"id":12408,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb\/11047\/revisions\/12408"}],"wp:attachment":[{"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/media?parent=11047"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb-category?post=11047"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/support.buildsoft.eu\/fr\/wp-json\/wp\/v2\/ht-kb-tag?post=11047"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}