<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>wind &#8211; BuildSoft Support</title>
	<atom:link href="https://support.buildsoft.eu/article-tags/wind/feed/" rel="self" type="application/rss+xml" />
	<link>https://support.buildsoft.eu</link>
	<description>BuildSoft Support</description>
	<lastBuildDate>Wed, 21 Aug 2024 07:09:26 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.2.14</generator>
	<item>
		<title>How to define wind loads in Diamonds</title>
		<link>https://support.buildsoft.eu/knowledge-base/how-to-define-wind-loads-in-diamonds/</link>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Wed, 21 Apr 2021 13:03:25 +0000</pubDate>
				<guid isPermaLink="false">http://buildsoftsupport.com/?post_type=ht_kb&#038;p=3070</guid>

					<description><![CDATA[Demo FAQ]]></description>
										<content:encoded><![CDATA[<h2>Demo</h2>
<p><iframe loading="lazy" src="https://player.vimeo.com/video/539631968" width="960" height="515&quot;" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<h2>FAQ</h2>
 
    		<div class="hts-accordion "  >

    			    				<div class="hts-accordion__section hts-accordion__section--active">
	    				<div class="hts-accordion__title">Why can't I select the entire 3D structure and run the wind load generator?</div>
	    				<div class="hts-accordion__content">
	    					<div class="hts-accordion__contentwrap">
	    						 Because it is impossible to write a good working algoritme for this. The algoritme should not only be able to distinguish all different floor plans/ roofs shapes, but it should also be able to make a meaningfull interpretation of it in order to generate the wind loads. For that reason BuildSoft has descided to keep the wind (and snow) generator 2D. This offers the most flexible solution.	    					</div>
	    				</div>
    				</div>
    			    				<div class="hts-accordion__section ">
	    				<div class="hts-accordion__title">Do I always need 24 sub load cases?</div>
	    				<div class="hts-accordion__content">
	    					<div class="hts-accordion__contentwrap">
	    						No. The number of required sub load cases depends on the shape of the roof and the number of internal pressure coefficients. The document at the end of this article explains which cases you need.&nbsp;If you don't feel like figuring out which cases you need, you can always generate all 24 cases. But for 3D structures like the one in the video, its worth verifying which cases you need as the calculation time increases when you have more load cases.	    					</div>
	    				</div>
    				</div>
    			    				<div class="hts-accordion__section ">
	    				<div class="hts-accordion__title">Will the wind generator also run for trusses, lattice structures, scaffoldings, billboards, .. ?</div>
	    				<div class="hts-accordion__content">
	    					<div class="hts-accordion__contentwrap">
	    						No. The wind generator as seen in the video is developed for buildings. As an alterantive you could enter the terrain parameters&nbsp;and apply a wind load on a group of bars (the selected bars must lie in the same plane). But this method implies that you manually look up the pressure coefficients and enter them in Diamonds.	    					</div>
	    				</div>
    				</div>
    			    			
    		</div><!-- /.ht-shortcodes-accordion -->
    		
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to consult the used cpe, cpi and wind pressure?</title>
		<link>https://support.buildsoft.eu/knowledge-base/how-to-consult-the-used-cpe-cpi-and-wind-pressure/</link>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Tue, 29 Jan 2019 09:21:22 +0000</pubDate>
				<guid isPermaLink="false">http://buildsoftsupport.com/?post_type=ht_kb&#038;p=3924</guid>

					<description><![CDATA[Go to&#160;My Documents &#62; Diamonds &#62; *CurrentDiamondsVersion*. Depending on your operating system, the name &#8216;My Documents&#8216; can be &#8216;Documents&#8216;. Add a txt-file in this folder. Name it &#8216;WindNorm&#8217;. Pay attention to the spelling and capital letters! Generate a wind load case in Diamonds. Now open the txt-file &#8216;WindNorm&#8217;. The used...]]></description>
										<content:encoded><![CDATA[<ul>
<li>Go to&nbsp;<strong>My Documents &gt; Diamonds &gt; <em>*CurrentDiamondsVersion*</em></strong>.<br />
Depending on your operating system, the name &#8216;<strong>My Documents</strong>&#8216; can be &#8216;<strong>Documents</strong>&#8216;.<img decoding="async" loading="lazy" class="alignnone size-full wp-image-3929" src="http://buildsoftsupport.com/wp-content/uploads/2019/01/WindNorm1.png" alt="" width="909" height="434" srcset="https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm1.png 909w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm1-300x143.png 300w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm1-768x367.png 768w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm1-50x24.png 50w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm1-60x29.png 60w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm1-35x17.png 35w" sizes="(max-width: 909px) 100vw, 909px" /></li>
<li>Add a txt-file in this folder. Name it &#8216;WindNorm&#8217;. Pay attention to the spelling and capital letters!<img decoding="async" loading="lazy" class="alignnone size-large wp-image-3926" src="http://buildsoftsupport.com/wp-content/uploads/2019/01/WindNorm2.png" alt="" width="643" height="610" srcset="https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm2.png 906w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm2-300x284.png 300w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm2-768x728.png 768w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm2-50x47.png 50w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm2-60x57.png 60w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm2-35x33.png 35w" sizes="(max-width: 643px) 100vw, 643px" /> <img decoding="async" loading="lazy" class="alignnone size-large wp-image-3927" src="http://buildsoftsupport.com/wp-content/uploads/2019/01/WindNorm3.png" alt="" width="643" height="327" srcset="https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm3.png 909w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm3-300x152.png 300w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm3-768x390.png 768w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm3-50x25.png 50w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm3-60x30.png 60w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm3-35x18.png 35w" sizes="(max-width: 643px) 100vw, 643px" /></li>
<li>Generate a wind load case in Diamonds.</li>
<li>Now open the txt-file &#8216;WindNorm&#8217;. The used c<sub>pe</sub>, c<sub>pi</sub> and pressure will be mentioned in the txt-file.<img decoding="async" loading="lazy" class="alignnone size-full wp-image-3928" src="http://buildsoftsupport.com/wp-content/uploads/2019/01/WindNorm4.png" alt="" width="506" height="605" srcset="https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm4.png 506w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm4-251x300.png 251w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm4-42x50.png 42w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm4-50x60.png 50w, https://support.buildsoft.eu/wp-content/uploads/2019/01/WindNorm4-29x35.png 29w" sizes="(max-width: 506px) 100vw, 506px" /></li>
</ul>
<p>Notes:</p>
<ul>
<li>If you want to maintain overview, generate only one wind load case at once. The lay-out of the txt-file is not made for large outputs.</li>
<li>It is not possible to print/ show this information in Diamonds.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to generate wind on a canopy roof</title>
		<link>https://support.buildsoft.eu/knowledge-base/how-to-generate-wind-on-a-canopy-roof/</link>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Wed, 17 Oct 2018 15:14:52 +0000</pubDate>
				<guid isPermaLink="false">http://buildsoftsupport.com/?post_type=ht_kb&#038;p=3607</guid>

					<description><![CDATA[Set the ground level&#160; and terrain parameters . Select a 2D frame and click on . Enter the distances for the position of the frame and select the option for a canopy roof. Select the desired load cases (see pdf document at the bottom of this article). Local coëfficients are...]]></description>
										<content:encoded><![CDATA[<ul>
<li>Set the ground level&nbsp;<img decoding="async" loading="lazy" class="img_inline alignnone size-full wp-image-3079" src="http://buildsoftsupport.com/wp-content/uploads/2018/07/ButtonGroundLevel.jpg" alt="" width="90" height="20" srcset="https://support.buildsoft.eu/wp-content/uploads/2018/07/ButtonGroundLevel.jpg 90w, https://support.buildsoft.eu/wp-content/uploads/2018/07/ButtonGroundLevel-50x11.jpg 50w, https://support.buildsoft.eu/wp-content/uploads/2018/07/ButtonGroundLevel-60x13.jpg 60w, https://support.buildsoft.eu/wp-content/uploads/2018/07/ButtonGroundLevel-35x8.jpg 35w" sizes="(max-width: 90px) 100vw, 90px" /> and terrain parameters <img decoding="async" loading="lazy" class="img_inline alignnone size-full wp-image-3087" src="http://buildsoftsupport.com/wp-content/uploads/2018/07/ButtonTerrainWind.jpg" alt="" width="37" height="36" srcset="https://support.buildsoft.eu/wp-content/uploads/2018/07/ButtonTerrainWind.jpg 37w, https://support.buildsoft.eu/wp-content/uploads/2018/07/ButtonTerrainWind-35x35.jpg 35w" sizes="(max-width: 37px) 100vw, 37px" />.</li>
<li>Select a 2D frame and click on <img decoding="async" loading="lazy" class="img_inline alignnone size-full wp-image-3095" src="http://buildsoftsupport.com/wp-content/uploads/2018/07/ButtonWindFrame.jpg" alt="" width="36" height="34" srcset="https://support.buildsoft.eu/wp-content/uploads/2018/07/ButtonWindFrame.jpg 36w, https://support.buildsoft.eu/wp-content/uploads/2018/07/ButtonWindFrame-35x33.jpg 35w" sizes="(max-width: 36px) 100vw, 36px" />.
<ul>
<li>Enter the distances for the position of the frame and select the option for a canopy roof.<img decoding="async" loading="lazy" class="alignnone size-large wp-image-3612" src="http://buildsoftsupport.com/wp-content/uploads/2018/10/CanopyWind1.png" alt="" width="643" height="569" srcset="https://support.buildsoft.eu/wp-content/uploads/2018/10/CanopyWind1.png 758w, https://support.buildsoft.eu/wp-content/uploads/2018/10/CanopyWind1-300x266.png 300w, https://support.buildsoft.eu/wp-content/uploads/2018/10/CanopyWind1-50x44.png 50w, https://support.buildsoft.eu/wp-content/uploads/2018/10/CanopyWind1-60x53.png 60w, https://support.buildsoft.eu/wp-content/uploads/2018/10/CanopyWind1-35x31.png 35w" sizes="(max-width: 643px) 100vw, 643px" /></li>
<li>Select the desired load cases (see pdf document at the bottom of this article).
<ul>
<li style="list-style-type: none;">
<ul>
<li>Local coëfficients are used for the design of roof covers and fasteners. Global coefficients are used for strength and stability checks.</li>
<li>The&nbsp;φ indicates the degree of blockage.&nbsp;φ = 0 for a freestanding canopy,&nbsp;φ = 1 for a blocked canopy (see Figure 7.15 in EN 1991-1-4).</li>
</ul>
</li>
</ul>
<p><img decoding="async" loading="lazy" class="alignnone size-full wp-image-3611" src="http://buildsoftsupport.com/wp-content/uploads/2018/10/CanopyWind2.png" alt="" width="758" height="671" srcset="https://support.buildsoft.eu/wp-content/uploads/2018/10/CanopyWind2.png 758w, https://support.buildsoft.eu/wp-content/uploads/2018/10/CanopyWind2-300x266.png 300w, https://support.buildsoft.eu/wp-content/uploads/2018/10/CanopyWind2-50x44.png 50w, https://support.buildsoft.eu/wp-content/uploads/2018/10/CanopyWind2-60x53.png 60w, https://support.buildsoft.eu/wp-content/uploads/2018/10/CanopyWind2-35x31.png 35w" sizes="(max-width: 758px) 100vw, 758px" /></li>
<li>Hit &#8216;OK&#8217;.</li>
<li>Repeat the same steps for the next frame.</li>
</ul>
</li>
</ul>
<p>Note: the windgenerator on canopy roofs only generates the wind loads on the roof! If the wind load is blocked, you should apply wind loads on the facade manually!</p>