<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>staalcontrole &#8211; BuildSoft Support</title>
	<atom:link href="https://support.buildsoft.eu/article-tags/staalcontrole/feed/" rel="self" type="application/rss+xml" />
	<link>https://support.buildsoft.eu</link>
	<description>BuildSoft Support</description>
	<lastBuildDate>Mon, 20 Oct 2025 09:58:58 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.2.9</generator>
	<item>
		<title>Error: There are bars for which the code check did not succeed. Arithmetic operation resulted in an overflow.</title>
		<link>https://support.buildsoft.eu/knowledge-base/there-are-bars-for-which-the-code-check-did-not-succeed/</link>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Thu, 14 Nov 2019 16:41:12 +0000</pubDate>
				<guid isPermaLink="false">http://buildsoftsupport.com/?post_type=ht_kb&#038;p=4814</guid>

					<description><![CDATA[During the steel check you get the error: [NL]: Voor bepaalde staven kon de normcontrole niet uitgevoerd worden. De rekenkundige bewerking heeft geresulteerd in een overloop. [FR]: La vérification ne pourraît pas être exécuté pour certaines barres. De objectverwijzing is niet op een exemplaar van een object ingesteld. Cause (in general) This...]]></description>
										<content:encoded><![CDATA[<p>During the steel check you get the error:</p>
<p><img decoding="async" loading="lazy" class="size-full wp-image-4816 aligncenter" src="http://buildsoftsupport.com/wp-content/uploads/2019/11/ErrorObjectOverflow.png" alt="" width="500" height="274" srcset="https://support.buildsoft.eu/wp-content/uploads/2019/11/ErrorObjectOverflow.png 500w, https://support.buildsoft.eu/wp-content/uploads/2019/11/ErrorObjectOverflow-300x164.png 300w, https://support.buildsoft.eu/wp-content/uploads/2019/11/ErrorObjectOverflow-50x27.png 50w, https://support.buildsoft.eu/wp-content/uploads/2019/11/ErrorObjectOverflow-60x33.png 60w, https://support.buildsoft.eu/wp-content/uploads/2019/11/ErrorObjectOverflow-35x19.png 35w" sizes="(max-width: 500px) 100vw, 500px" /></p>
[NL]: <em>Voor bepaalde staven kon de normcontrole niet uitgevoerd worden. De rekenkundige bewerking heeft geresulteerd in een overloop.</em></p>
[FR]: <em>La vérification ne pourraît pas être exécuté pour certaines barres. De objectverwijzing is niet op een exemplaar van een object ingesteld.</em></p>
<h2>Cause (in general)</h2>
<p>This error is always related to an inconsistency in the dimensions of the used cross-section(s). Resulting in cross-section classifications, imperfection factors, effective properties, &#8230; not being calculated automatically.</p>
<h4>Example 1:</h4>
<p>An RHS-section is used to create an elliptical cross-section. But because r0 (=25mm) equals B/2 (=50mm/2), the cross-section classification in the weak direction cannot be performed.<br />
Solution: set B= 51mm or set r0 to 24mm.<br />
<img decoding="async" loading="lazy" class="size-full wp-image-13959 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2019/11/ErrorStaalcontrole.png" alt="" width="849" height="343" /></p>
<h4>Example 2:</h4>
<p>Some cross-section shapes are associated with cold-formed sections, like these in the list below:<img decoding="async" loading="lazy" class="size-full wp-image-4817 aligncenter" src="http://buildsoftsupport.com/wp-content/uploads/2019/11/FiguurKoudgevormd.png" alt="" width="270" height="279" srcset="https://support.buildsoft.eu/wp-content/uploads/2019/11/FiguurKoudgevormd.png 270w, https://support.buildsoft.eu/wp-content/uploads/2019/11/FiguurKoudgevormd-48x50.png 48w, https://support.buildsoft.eu/wp-content/uploads/2019/11/FiguurKoudgevormd-58x60.png 58w, https://support.buildsoft.eu/wp-content/uploads/2019/11/FiguurKoudgevormd-35x35.png 35w" sizes="(max-width: 270px) 100vw, 270px" /></p>
<p>When the option &#8216;Automatic calculation&#8217; is selected, Diamonds calculates the general, elastic (except T<sub>wm</sub>) and the plastic properties of the cross-section.<img decoding="async" loading="lazy" class="size-large wp-image-4818 aligncenter" src="http://buildsoftsupport.com/wp-content/uploads/2019/11/FiguurKoudgevormd2.png" alt="" width="600" height="296" srcset="https://support.buildsoft.eu/wp-content/uploads/2019/11/FiguurKoudgevormd2.png 600w, https://support.buildsoft.eu/wp-content/uploads/2019/11/FiguurKoudgevormd2-300x148.png 300w, https://support.buildsoft.eu/wp-content/uploads/2019/11/FiguurKoudgevormd2-50x25.png 50w, https://support.buildsoft.eu/wp-content/uploads/2019/11/FiguurKoudgevormd2-60x30.png 60w, https://support.buildsoft.eu/wp-content/uploads/2019/11/FiguurKoudgevormd2-35x17.png 35w" sizes="(max-width: 600px) 100vw, 600px" /><br />
But Diamonds cannot calculate the effective and design properties for these cross-section shapes. These shapes are in Diamonds because manufacturers (Joris Ide, Brausa, Sadef, &#8230;) provided us with lists of common cross-sections with their dimensions and effective properties. So although you can play around with the dimensions, Diamonds is not capable of calculating the effective properties!<br />
<img decoding="async" loading="lazy" class="size-large wp-image-4819 aligncenter" src="http://buildsoftsupport.com/wp-content/uploads/2019/11/FiguurKoudgevormd3.png" alt="" width="604" height="305" srcset="https://support.buildsoft.eu/wp-content/uploads/2019/11/FiguurKoudgevormd3.png 604w, https://support.buildsoft.eu/wp-content/uploads/2019/11/FiguurKoudgevormd3-300x151.png 300w, https://support.buildsoft.eu/wp-content/uploads/2019/11/FiguurKoudgevormd3-50x25.png 50w, https://support.buildsoft.eu/wp-content/uploads/2019/11/FiguurKoudgevormd3-60x30.png 60w, https://support.buildsoft.eu/wp-content/uploads/2019/11/FiguurKoudgevormd3-35x18.png 35w" sizes="(max-width: 604px) 100vw, 604px" /></p>
<p>So if you want to perform a steel verification on these cross-section shapes, you should:</p>
<ul>
<li>Check the option &#8216;Automatic Calculation&#8217;. This way the general, elastic and plastic properties are calculated.</li>
<li>Uncheck the option &#8216;Automatic calculation&#8217;. This way you can adjust the value of T<sub>wm</sub> in the tab page &#8216;Elastic&#8217;.</li>
<li>Define all the properties in the tab page &#8216;Effective&#8217;.</li>
<li>Define all the properties in the tab page &#8216;Design&#8217;.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to do steel design</title>
		<link>https://support.buildsoft.eu/knowledge-base/how-to-do-a-steel-verification/</link>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Thu, 30 Aug 2018 14:31:50 +0000</pubDate>
				<guid isPermaLink="false">http://buildsoftsupport.com/?post_type=ht_kb&#038;p=3454</guid>

					<description><![CDATA[To assess a structure (whether it is sufficiant or not), the following steps must be followed in sequence: Schematising the construction Determining the internal forces and moments (= global analysis) Checking the cross-sections (= design): Strength Stability  Stiffness The explanation below covers the design of steel. In Diamonds Calculate the...]]></description>
										<content:encoded><![CDATA[<p>To assess a structure (whether it is sufficiant or not), the following steps must be followed in sequence:</p>
<ul>
<li>Schematising the construction</li>
<li>Determining the internal forces and moments (= global analysis)</li>
<li><strong>Checking the cross-sections (= design):</strong>
<ul>
<li><strong>Strength</strong></li>
<li><strong>Stability </strong></li>
<li><strong>Stiffness</strong></li>
</ul>
</li>
</ul>
<p>The explanation below covers the design of steel.</p>
<h2>In Diamonds</h2>
<ul>
<li><a href="http://buildsoftsupport.com/knowledge-base/how-to-do-the-elastic-analysis-for-steel/">Calculate the internal forces (syn. global analysis)</a> <kbd>F9</kbd> or <img decoding="async" loading="lazy" class="img_inline alignnone size-full wp-image-1546" src="http://buildsoftsupport.com/wp-content/uploads/2017/09/Calculate.png" alt="" width="24" height="26" />.</li>
<li><a href="http://buildsoftsupport.com/knowledge-base/how-to-set-the-buckling-lengths/">Set the buckling lengths</a>.<br />
Don&#8217;t skip this step! Without the correct buckling lengths the stability results have no meaning.</li>
<li><a href="https://support.buildsoft.eu/docs/diamonds/geometry-palette/buckling-and-lateral-buckling-parameters/settings-for-lateral-torsional-buckling/" target="_blank" rel="noopener">Define the lateral torsional buckling supports</a> (if relevant).</li>
<li>Select the correct steel standard using the menu <em><strong>Analysis &gt; Steel standard</strong></em>.<br />
A list with all available standards in Diamonds can be found <a href="https://support.buildsoft.eu/knowledge-base/which-codes-standards-are-implemented-in-diamonds/" target="_blank" rel="noopener">here</a>.</li>
<li>Click on <kbd>F3</kbd> or <img decoding="async" loading="lazy" class="img_inline alignnone size-full wp-image-3446" src="http://buildsoftsupport.com/wp-content/uploads/2018/08/ButtonSteelVerificationTimberVerification.jpg" alt="" width="26" height="26" /> to start the verification (<a href="https://support.buildsoft.eu/docs/diamonds/steel-and-timber-verification/check-resistance-and-stability/" target="_blank" rel="noopener">more info</a>).</li>
<li>Decide whether <strong>global</strong> <strong>imperfections</strong> are necessary or not.</li>
<li>View the results with <img decoding="async" loading="lazy" class="img_inline alignnone size-full wp-image-3455" src="http://buildsoftsupport.com/wp-content/uploads/2018/08/ButtonStabilityStrength.jpg" alt="" width="34" height="32" />. For the results of the strength check click <img decoding="async" loading="lazy" class="img_inline alignnone size-full wp-image-3456" src="http://buildsoftsupport.com/wp-content/uploads/2018/08/ButtonStrength.jpg" alt="" width="35" height="37" srcset="https://support.buildsoft.eu/wp-content/uploads/2018/08/ButtonStrength.jpg 35w, https://support.buildsoft.eu/wp-content/uploads/2018/08/ButtonStrength-33x35.jpg 33w" sizes="(max-width: 35px) 100vw, 35px" />, for those of the stability check click <img decoding="async" loading="lazy" class="img_inline alignnone size-full wp-image-3457" src="http://buildsoftsupport.com/wp-content/uploads/2018/08/ButtonStability.jpg" alt="" width="35" height="37" srcset="https://support.buildsoft.eu/wp-content/uploads/2018/08/ButtonStability.jpg 35w, https://support.buildsoft.eu/wp-content/uploads/2018/08/ButtonStability-33x35.jpg 33w" sizes="(max-width: 35px) 100vw, 35px" />.<br />
The results of the strength and stability check are displayed as a percentage of the total capacity (= 100%) of the section.</p>
<ul>
<li>A structure is sufficient for strength, if the percentage is less than 100% for all bars.</li>
<li>A structure is sufficient for stability, if the percentage is less than 100% for all bars.</li>
</ul>
<p>Based on the percentage no judgment can be made on the extent to which a section is sufficient or not. This is because the used formulas are not always linear.</li>
<li>Optionally, optimize the cross-sections.<br />
You can use the <a href="https://support.buildsoft.eu/docs/diamonds/steel-and-timber-verification/optimization-strength-and-stability/" target="_blank" rel="noopener">Optimization-function</a> for this <img decoding="async" loading="lazy" class="alignnone size-full wp-image-17510" src="https://support.buildsoft.eu/wp-content/uploads/2025/09/KnopOptimalisatie.png" alt="" width="20" height="20" />, but it might take a few iterations (and thus time).<br />
We recommend that you change the cross-sections manually to one (or more) size(s) bigger/smaller depending on the result you had then recalculating the model. Exspecially for experienced engineer, this works faster than the Optimization function.</li>
<li>Don&#8217;t forget to verify the stiffness! Thus the <strong>vertical and horizontal deformation.<br />
</strong>Diamonds can calculate <a href="https://support.buildsoft.eu/knowledge-base/how-to-request-the-relative-deflection/" target="_blank" rel="noopener">the relative deformation</a>, but it&#8217;s still up to you to verify it.<br />
A structure is sufficient if the strength, stability and stiffness are sufficient.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>No steel verification for Section Utility profile</title>
		<link>https://support.buildsoft.eu/knowledge-base/no-steel-verification-for-section-utility-profile/</link>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Thu, 23 Mar 2017 15:33:51 +0000</pubDate>
				<guid isPermaLink="false">http://buildsoftsupport.com/?post_type=ht_kb&#038;p=151</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[    		<div class="hts-messages hts-messages--alert   hts-messages--withicon " id="" style="">
    			    			    				<p>
    					The verification/ unity check of user defined cross-sections (using the tool Section Utility) is only supported for steel cross-sections according to Eurocode.     				</p>
    			    			
    		</div><!-- /.ht-shortcodes-messages -->
    		
<div class="su-tabs su-tabs-style-default su-tabs-mobile-stack" data-active="1" data-scroll-offset="0" data-anchor-in-url="no"><div class="su-tabs-nav"><span class="" data-anchor="EN" data-url="" data-target="" tabindex="0" role="button">EN</span><span class="" data-anchor="NL" data-url="" data-target="" tabindex="0" role="button">NL</span><span class="" data-anchor="FR" data-url="" data-target="" tabindex="0" role="button">FR</span></div><div class="su-tabs-panes"><div class="su-tabs-pane su-u-clearfix su-u-trim" data-title="EN">
<h2>Problem</h2>
<p>There are no strength/ stability results available for a custom cross-section (Section utility) after a steelcheck.</p>
<h2>Solution</h2>
<p>In order to perform a steelcheck, elastic and plastic section properties are not sufficient. Eurocode requires additional parameters. Eurocode gives rules to determine those additional parameters in case of I, T, H, O, L and tubular cross-sections. But for a combination of these cross-sections or for a random cross-section there are not rules given. Eurocode will have to be interpreted in order to determine a meaningful value for these additional parameters. And that is a job for the end user. The additional parameters can be defined in Section Utility:</p>
<ol>
<li>Open the cross section Section Utility</li>
<li>Click on the button &#8220;<i>Imposed classes&#8221;</i> at the right bottom side</li>
<li>Enter the requested parameters. An overview can be found in the download links below.</li>
</ol>
<p>Some time ago, we hosted a webinar about composed Section-Utility cross-sections and the steel verficiation. You can <a href="https://buildsoftsupport.com/knowledge-base/where-can-i-review-the-webinars/">review all webinars here</a>.</p>
</div>
<div class="su-tabs-pane su-u-clearfix su-u-trim" data-title="NL">
<h2>Probleem</h2>
<p>Na een staalcontrole zijn er geen resultaten beschikbaar voor een zelf samengesteld (uit Section Utility) profiel.</p>
<h2>Oplossing</h2>
<p>Om een staalcontrole te kunnen uitvoeren, heb je niet enkel elastische en plastische eigenschappen nodig. Eurocode vereist nog bijkomende eigenschappen. Voor standaard&nbsp;I, T, H, O, L, en buisvormige doorsnede geeft Eurocode regels om die bijkomende eigenschappen te bepalen. Maar niet voor gecombineerde doorsnede of willekeurige doorsnedes. Om de bijkomende parameters voor deze doorsnedes een zinvolle waarde te geven, moet Eurocode geïnterpreteerd worden. En dat is de taak van de gebruiker. De bijkomende eigenschappen kunnen gedefinieerd worden in Section Utility:</p>
<ol>
<li>Open de samengestelde doorsnede in Section Utility.</li>
<li>Aan de recht kant, klik op de knop &#8220;<em>Opgelegde sectieklassen&#8221;</em>.</li>
<li>In het dialoogvenster dat verschijnt zie je alle parameters die bepaald moeten worden. Een overzicht kan je vinden in de bestanden onderaan dit artikel.</li>
</ol>
<p>Enige tijd geleden hebben we een webinar gegeven over samengestelde doorsneden in Section Utility en de staalcontrole. Je kan deze webinar (en alle andere webinars) <a href="https://buildsoftsupport.com/knowledge-base/where-can-i-review-the-webinars/">hier herbekijken</a>.</p>
</div>
<div class="su-tabs-pane su-u-clearfix su-u-trim" data-title="FR">
<h2>Problème</h2>
<p>Après une vérification acier, aucun résultat n&#8217;est disponible pour une section composée&nbsp;( = profil de Section Utility).</p>
<h2>Solution</h2>
<p>Pour pouvoir effectuer une vérification acier, vous n&#8217;avez pas seulement besoin de propriétés élastiques et plastiques. L&#8217;Eurocode requiert des propriétés supplémentaires. Pour les sections standard I, T, H, O, L et tubulaires, l&#8217;Eurocode fournit des règles pour déterminer ces propriétés supplémentaires. Mais pas pour les sections combinées ou les sections arbitraires. Pour donner aux paramètres supplémentaires de ces sections une valeur significative, l&#8217;Eurocode doit être interprété. Et c&#8217;est le travail de l&#8217;utilisateur. Les propriétés supplémentaires peuvent être définies dans Section Utility :</p>
<ol>
<li>Ouvriez la section&nbsp;composée en Section Utility.</li>
<li>Sur le côté droit, cliquez sur le bouton &#8216;<em>Classes imposées&#8230;</em>&#8216;.</li>
<li>Dans la boîte de dialogue qui apparaît, vous verrez tous les paramètres qui doivent être déterminés. Un aperçu peut être trouvé dans les fichiers au bas de cet article.</li>
</ol>
<p>Il y a quelque temps, nous avons donné un webinaire sur les sections composées dans Section Utility et la vérification acier. Vous pouvez revoir ce webinaire (et tous les autres webinaires) <a href="https://buildsoftsupport.com/knowledge-base/where-can-i-review-the-webinars/">ici</a>.</p>
</div></div></div>
<p><script src="chrome-extension://kcgedkeajhbfkackhppmenimpfpnopje/js/app.js" type="text/javascript"></script></p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
