<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>To PowerConnect &#8211; BuildSoft Support</title>
	<atom:link href="https://support.buildsoft.eu/article-categories/bim_workflows_pwc_topwc/feed/" rel="self" type="application/rss+xml" />
	<link>https://support.buildsoft.eu</link>
	<description>BuildSoft Support</description>
	<lastBuildDate>Thu, 20 Feb 2025 09:16:30 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.2.14</generator>
	<item>
		<title>From SAF to PowerConnect</title>
		<link>https://support.buildsoft.eu/knowledge-base/from-saf-to-powerconnect/</link>
		
		<dc:creator><![CDATA[Dorothee]]></dc:creator>
		<pubDate>Tue, 04 Feb 2025 10:02:46 +0000</pubDate>
				<guid isPermaLink="false">https://support.buildsoft.eu/?post_type=ht_kb&#038;p=14519</guid>

					<description><![CDATA[This article explains how to send one or more SAF nodes to PowerConnect, using BIM Expert. 1. Good to know SAF (Structural Analysis Format) is a file format that is supported by many programs, so this workflow can also be used when you want to go In the relevant software,...]]></description>
										<content:encoded><![CDATA[
<p>This article explains how to send one or more SAF nodes to PowerConnect, using BIM Expert.<br></p>



<span id="more-14519"></span>



<h2 class="wp-block-heading" id="1-preparation-in-revit"><strong>1. Good to know</strong></h2>



<p>SAF (Structural Analysis Format) is a file format that is <a rel="noreferrer noopener" href="https://www.saf.guide/en/stable/getting-started/who-supports-saf.html" target="_blank">supported by many programs</a>, so this workflow can also be used when you want to go </p>



<ul>
<li>From <strong>SCIA Engineer</strong> to PowerConnect</li>



<li>From <strong>Risa </strong>to PowerConnect</li>



<li>From <strong>Graphisoft / Archicad </strong>to PowerConnect</li>



<li>From <strong>Allplan </strong>to PowerConnect</li>



<li>From <strong>RadImpex </strong>to PowerConnect</li>



<li>From <strong>AxisVM </strong>to PowerConnect</li>



<li>From <strong>Sofistik </strong>to PowerConnect</li>



<li>From <strong>Dlubal </strong>to PowerConnect</li>



<li>From <strong>mbAECStrukturEditor </strong>to PowerConnect</li>



<li>From <strong>D.I.E</strong> to PowerConnect</li>



<li>From <strong>InfoGraph </strong>to PowerConnect</li>



<li>From <strong>NextFEM </strong>to PowerConnect</li>



<li>From <strong>MasterSap </strong>to PowerConnect</li>



<li>From <strong>Prota Structure</strong> to PowerConnect</li>



<li>From <strong>Karamba3D </strong>to PowerConnect</li>
</ul>



<p>In the relevant software, make an export to SAF file and continue with the steps below.</p>



<h2 class="wp-block-heading" id="2-send-the-revit-model-to-tekla-structures"><strong>2. Send the SAF model to PowerConnect<br></strong></h2>



<h3 class="wp-block-heading" id="2-1-from-revit-to-bim-expert">2.1 From SAF to BIM Expert</h3>


In the Model tab, select ‘Import’. Next, choose &#8216;SAF&#8217;. Click <img decoding="async" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" sizes="(max-width: 29px) 100vw, 29px" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" alt="" width="29" height="28" /> to continue.
<img decoding="async" loading="lazy" class="wp-image-14607 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2025/01/bimexpert_importfromsaf.png" alt="" width="253" height="258" />

&nbsp;
<h4 id="2-1-2-material-mapping">2.1.1 Material mapping</h4>
Database materials such as steel (e.g. S235, ASTM-Grades), concrete (e.g. C25/30, M50) and timber (e.g. C24, D50, GL28c) are mapped automatically. In some cases, the match is not automatically found, because the name differs (<em>Concrete grade C25</em> instead of <em>Concrete grade C25/30</em>). In that case, you can select the correct material from the database. Below the material list, there is a list of the current selected material&#8217;s properties.

<img decoding="async" loading="lazy" class="wp-image-14606 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2025/01/bimexpert_importfromsaf_materialmapping.png" alt="" width="395" height="412" />

If you cannot find a suited counterpart in the BIM Expert database, the material can be added as new.
<h4 id="2-1-2-material-mapping">2.1.2 Section mapping</h4>
Database sections (such as I, H, UB, UC, W, C, U, O, ☐ and L sections) are mapped automatically. In some cases, the match is not automatically found, because the name differs  (e.g. name is <em>HEB300 – S235</em> instead of <em>HEB300</em>). In that case, you can select the correct cross-section from the database.

<img decoding="async" loading="lazy" class="wp-image-14605 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2025/01/bimexpert_importfromsaf_sectionmapping.png" alt="" width="531" height="351" />

Parametric sections (e.g. rectangles, circle, trapezium, …) and user defined sections are not in the database. They should always be added as new.

The model is now in BIM Expert.



<h3 class="wp-block-heading">2.2 From BIM Expert to PowerConnect</h3>


<p>In the Model tab, select ‘Export’. Next, choose the destination software, namely PowerConnect. Click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" sizes="(max-width: 29px) 100vw, 29px" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" alt="" width="29" height="28" /> to continue.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9530 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png" alt="" width="397" height="241" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png 602w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-300x182.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-50x30.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-60x36.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-35x21.png 35w" sizes="(max-width: 397px) 100vw, 397px" /></p>
<h4 id="2-2-1-settings">2.2.1 Settings</h4>
<p>You can choose to either</p>
<ul>
<li>save the model as *.bpc-file</li>
<li>send the model to the current open PowerConnect instance &#8211; you see all open instances of PowerConnect</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9533 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png" alt="" width="564" height="152" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png 735w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-300x81.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-50x13.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-60x16.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-35x9.png 35w" sizes="(max-width: 564px) 100vw, 564px" /></p>
<p>Select your choice and click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" alt="" width="29" height="28" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" sizes="(max-width: 29px) 100vw, 29px" /> to continue.</p>
<h5>2.2.2 Automatic detection of connection components</h5>
<p>BIM Expert automatically detects existing connection components in the model. You get an overview of all found connection components and whether they can be transferred to PowerConnect.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9569 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png" alt="" width="790" height="349" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png 1654w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-300x132.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-768x339.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-1024x452.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-50x22.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-60x26.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-35x15.png 35w" sizes="(max-width: 790px) 100vw, 790px" /></p>
<p>&nbsp;</p>
<p>Use the eye button in the &#8216;Show&#8217; column to see a detailed popup window of the connection.</p>
<p>Possible descriptions are</p>
<ul>
<li><em>Some internal forces could not be retrieved from the analysis results</em><br />
No (or not all) internal forces are present from the source software.</li>
<li><em>The connection is identical to connection(s) {IDs} and therefore has been grouped</em><br />
Identical connections will be treated as one connection. You must only calculate the connections one, with envelope forces.</li>
<li><em>Connection merged with one or more parts of the following connection: {ID}</em><br />
The connection is merged with other one to create a more complex connection (e.g. two shear connections to beam-column are merged to design a double-sided shear connection)</li>
<li><em>Connection divided into &lt;&#8230;.&gt; connections </em><br />
A complex connection has been split up into smaller PowerConnect connections</li>
<li><em>The connection bars/plates with following ID&#8217;s could not be recognized: {IDs} </em><br />
The connection is recognized and can be calculated with PowerConnect, execpt for these bars/plates, with given Ids</li>
<li><em>Connection type not support</em><br />
This connection configuration cannot be calculated by PowerConnect, so it will not be transferred.</li>
</ul>
<p>If no connections are found, you will see</p>
<p><img decoding="async" loading="lazy" class="wp-image-9573 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png" alt="" width="381" height="223" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png 538w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-300x176.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-50x29.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-60x35.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-35x20.png 35w" sizes="(max-width: 381px) 100vw, 381px" /></p>
<h4>2.2.3 Add connections manually via Connection Assembler</h4>
<p>You can make your own connections by clicking ‘Modify’ (see image above).</p>
<p>In the next window, you see on the left hand side the BIM Expert model. In this window you see the regular scroll, 3D orbit and pan functions. On the right hand side, there is on top an overview of created connections and at the bottom, the &#8216;Create&#8217; button to make new connections.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9546 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png" alt="" width="712" height="356" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png 1553w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-300x150.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-768x384.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-1024x512.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-50x25.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-60x30.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-35x18.png 35w" sizes="(max-width: 712px) 100vw, 712px" /></p>
<p>In the next step you choose the connection type</p>
<ul>
<li>Moment connections: beam-column, beam-beam, splice, beam-column-beam or CHS splice</li>
<li>Shear connections: beam-column or beam-beam, beam-column-beam or beam-beam-beam</li>
<li>Base plate connections</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9537 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler2.png" alt="" width="777" height="192" /></p>
<p>After selecting for example ‘Beam to column’ you select the column and next the beam element from the 3D image on the left hand side. Click once on the column element and next on the beam element. BIM Expert will list and indicate which connections are possible:</p>
<ul>
<li>Beam to column flange &gt; possible, and marked with <img decoding="async" loading="lazy" class="alignnone size-full wp-image-9559" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_check.png" alt="" width="20" height="20" /></li>
<li>Beam to column web &gt; not possible, and not marked – you can click the orange arrow <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9558 size-full" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_arrow.png" alt="" width="21" height="20" />at the end to fold out the details and see why this connection is not possible.</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9542 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png" alt="" width="350" height="348" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png 587w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-150x150.png 150w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-300x298.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-50x50.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-60x60.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-35x35.png 35w" sizes="(max-width: 350px) 100vw, 350px" /></p>
<p>On clicking ‘Create’, the connection is added to the list of connections on top. Having selected the beam-column type, you can now continue making this type of connections, until you click ‘Change pattern’.</p>
<p><img decoding="async" loading="lazy" class=" wp-image-9543 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png" alt="" width="391" height="354" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png 583w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-300x271.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-50x45.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-60x54.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-35x32.png 35w" sizes="(max-width: 391px) 100vw, 391px" /></p>
<p>When the connection definition is finished, you click ‘Close’ and ‘Accept’ to continue to PowerConnect.</p>
<p>If you have chosen to open the model directly in PowerConnect, you will get a notification in PowerConnect on the right side. You can now choose to load the model or to delete it (by using the ‘x’).</p>
<p><img decoding="async" loading="lazy" class="wp-image-9553 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png" alt="" width="403" height="160" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png 549w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-300x119.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-50x20.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-60x24.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-35x14.png 35w" sizes="(max-width: 403px) 100vw, 403px" /></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>




<h2 class="wp-block-heading" id="1-preparation-in-revit"><strong>3. Final steps in PowerConnect</strong></h2>


<p>All connections will appear in the node list on the left side (as from PowerConnect 2021).  Remember that all identical connections will be grouped as 1.</p>
<p>Connections made with the Connection Assembler might appear with a red bar and as &#8216;Undefined&#8217;.  The connector type must be chosen (e.g. end plate, shear plate, welded, angles etc)</p>
<p><img decoding="async" loading="lazy" class="wp-image-9555 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png" alt="" width="817" height="282" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png 1731w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-300x103.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-768x265.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-1024x353.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-50x17.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-60x21.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-35x12.png 35w" sizes="(max-width: 817px) 100vw, 817px" /></p>
<p>Click on this connection to set the connector.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9554 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png" alt="" width="765" height="284" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png 1729w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-300x111.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-768x285.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-1024x380.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-50x19.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-60x22.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-35x13.png 35w" sizes="(max-width: 765px) 100vw, 765px" /></p>
<p>If no loads or internal forces were transferred, you should add loads in PowerConnect, in order to have a proper design of the connections.<script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>




<div>
<h2 id="1-preparation-in-revit" class="wp-block-heading"><strong>4. Get started with BIM Expert<br />
</strong></h2>
</div>
<div style="text-align: left;"><div class="su-button-center"><a href="https://support.buildsoft.eu" class="su-button su-button-style-flat" style="color:#FFFFFF;background-color:#E74C3C;border-color:#b93d30;border-radius:0px" target="_blank" rel="noopener noreferrer"><span style="color:#FFFFFF;padding:8px 26px;font-size:20px;line-height:30px;border-color:#ef8277;border-radius:0px;text-shadow:none"><i class="sui sui-arrow-right" style="font-size:20px;color:#FFFFFF"></i> Download your free trial of BIM Expert</span></a></div></div>
<div><div class="su-spacer" style="height:75px"></div></div>

]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>From Tekla Structural Designer to PowerConnect</title>
		<link>https://support.buildsoft.eu/knowledge-base/from-tekla-structural-designer-to-powerconnect/</link>
		
		<dc:creator><![CDATA[Dorothee]]></dc:creator>
		<pubDate>Tue, 23 May 2023 08:36:42 +0000</pubDate>
				<guid isPermaLink="false">https://support.buildsoft.eu/?post_type=ht_kb&#038;p=9657</guid>

					<description><![CDATA[This article explains how to send one or more Tekla Structural Designer nodes to PowerConnect, using BIM Expert. 1. Preparation in Tekla Structural Designer 2. Send model from Tekla Structural Designer to PowerConnect 2.1 From Tekla Structural Designer to BIM Expert 2.2 From BIM Expert to PowerConnect 3. Final steps...]]></description>
										<content:encoded><![CDATA[<p>This article explains how to send one or more Tekla Structural Designer nodes to PowerConnect, using BIM Expert.<br />
<span id="more-9657"></span></p>
<h2 style="text-align: left;"><strong>1. Preparation in Tekla Structural Designer<br />
</strong></h2>
<p>    		<div class="hts-messages hts-messages--alert  hts-messages--withtitle hts-messages--withicon " id="" style="">
    			<span class="hts-messages__title">Attention</span>    			    				<p>
    					The conversion is only on geometry, loads should always be added in PowerConnect.    				</p>
    			    			
    		</div><!-- /.ht-shortcodes-messages -->
    		<br />
<p>The conversion is based on the .cxl file format. The .cxl file format is an XML based neutral file format that allows applications to link with Tekla Structural Designer. Tekla Structural Designer accepts and produces files in the .cxl neutral file format.</p>
<ol>
<li class="li step stepexpand"><span class="ph cmd">Create the model as usual. </span></li>
<li class="li step stepexpand"><span class="ph cmd">On the <span class="ph uicontrol">BIM Integration</span> tab, click <span class="ph uicontrol">Autodesk Revit Export</span>. </span>The <span class="ph"><span class="ph uicontrol">BIM Integration</span> wizard</span> opens.</li>
<li class="li step stepexpand"><span class="ph cmd">Adjust the location and rotation of the model, and click <span class="ph uicontrol"> &#8216;Next&#8217;</span>. </span></li>
<li class="li step stepexpand"><span class="ph cmd">Select the items that are included in the model, and click <span class="ph uicontrol"> &#8216;Next&#8217;</span>. </span></li>
<li class="li step stepexpand"><span class="ph cmd">Specify the export names of material grades, and click <span class="ph uicontrol"> &#8216;Next&#8217;</span>. </span></li>
<li class="li step stepexpand"><span class="ph cmd">Specify the file name and location. </span></li>
<li class="li step stepexpand"><span class="ph cmd">Select whether the file is exported for the first time, or whether you want to update an existing model. </span></li>
<li class="li step stepexpand"><span class="ph cmd">Click &#8216;<span class="ph uicontrol">Finish&#8217;</span>. </span></li>
</ol>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<h2 id="1-preparation-in-revit"><strong>2. Send model from Tekla Structural Designer to PowerConnect</strong></h2>
<h3>2.1 From Tekla Structural Designer to BIM Expert</h3>
<p><p>In the Model tab, select ‘Import’. Next, choose &#8216;CXL&#8217;. Click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" sizes="(max-width: 29px) 100vw, 29px" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" alt="" width="29" height="28" /> to continue.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9629 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcxl.png" alt="" width="276" height="268" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcxl.png 375w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcxl-300x292.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcxl-50x50.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcxl-60x58.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcxl-35x35.png 35w" sizes="(max-width: 276px) 100vw, 276px" /></p>
<p>The model is now in BIM Expert.</p>
<h4 id="2-1-2-material-mapping">2.1.1 Material &amp; section mapping</h4>
<p>Most common materials and sections are mapped according to the TSD neutral file mapping conventions. If there is no match found, a default section and material will be applied. You can specify these defaults in &#8216;File &gt; Settings &gt; CXL&#8217;</p>
<p><img decoding="async" loading="lazy" class="wp-image-9632 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcxl_defaults.png" alt="" width="374" height="134" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcxl_defaults.png 496w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcxl_defaults-300x108.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcxl_defaults-50x18.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcxl_defaults-60x22.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcxl_defaults-35x13.png 35w" sizes="(max-width: 374px) 100vw, 374px" /></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<h3 id="2-2-from-bim-expert-to-tekla-structures">2.2 From BIM Expert to PowerConnect</h3>
<p><p>In the Model tab, select ‘Export’. Next, choose the destination software, namely PowerConnect. Click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" sizes="(max-width: 29px) 100vw, 29px" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" alt="" width="29" height="28" /> to continue.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9530 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png" alt="" width="397" height="241" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png 602w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-300x182.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-50x30.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-60x36.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-35x21.png 35w" sizes="(max-width: 397px) 100vw, 397px" /></p>
<h4 id="2-2-1-settings">2.2.1 Settings</h4>
<p>You can choose to either</p>
<ul>
<li>save the model as *.bpc-file</li>
<li>send the model to the current open PowerConnect instance &#8211; you see all open instances of PowerConnect</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9533 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png" alt="" width="564" height="152" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png 735w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-300x81.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-50x13.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-60x16.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-35x9.png 35w" sizes="(max-width: 564px) 100vw, 564px" /></p>
<p>Select your choice and click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" alt="" width="29" height="28" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" sizes="(max-width: 29px) 100vw, 29px" /> to continue.</p>
<h5>2.2.2 Automatic detection of connection components</h5>
<p>BIM Expert automatically detects existing connection components in the model. You get an overview of all found connection components and whether they can be transferred to PowerConnect.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9569 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png" alt="" width="790" height="349" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png 1654w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-300x132.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-768x339.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-1024x452.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-50x22.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-60x26.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-35x15.png 35w" sizes="(max-width: 790px) 100vw, 790px" /></p>
<p>&nbsp;</p>
<p>Use the eye button in the &#8216;Show&#8217; column to see a detailed popup window of the connection.</p>
<p>Possible descriptions are</p>
<ul>
<li><em>Some internal forces could not be retrieved from the analysis results</em><br />
No (or not all) internal forces are present from the source software.</li>
<li><em>The connection is identical to connection(s) {IDs} and therefore has been grouped</em><br />
Identical connections will be treated as one connection. You must only calculate the connections one, with envelope forces.</li>
<li><em>Connection merged with one or more parts of the following connection: {ID}</em><br />
The connection is merged with other one to create a more complex connection (e.g. two shear connections to beam-column are merged to design a double-sided shear connection)</li>
<li><em>Connection divided into &lt;&#8230;.&gt; connections </em><br />
A complex connection has been split up into smaller PowerConnect connections</li>
<li><em>The connection bars/plates with following ID&#8217;s could not be recognized: {IDs} </em><br />
The connection is recognized and can be calculated with PowerConnect, execpt for these bars/plates, with given Ids</li>
<li><em>Connection type not support</em><br />
This connection configuration cannot be calculated by PowerConnect, so it will not be transferred.</li>
</ul>
<p>If no connections are found, you will see</p>
<p><img decoding="async" loading="lazy" class="wp-image-9573 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png" alt="" width="381" height="223" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png 538w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-300x176.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-50x29.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-60x35.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-35x20.png 35w" sizes="(max-width: 381px) 100vw, 381px" /></p>
<h4>2.2.3 Add connections manually via Connection Assembler</h4>
<p>You can make your own connections by clicking ‘Modify’ (see image above).</p>
<p>In the next window, you see on the left hand side the BIM Expert model. In this window you see the regular scroll, 3D orbit and pan functions. On the right hand side, there is on top an overview of created connections and at the bottom, the &#8216;Create&#8217; button to make new connections.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9546 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png" alt="" width="712" height="356" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png 1553w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-300x150.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-768x384.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-1024x512.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-50x25.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-60x30.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-35x18.png 35w" sizes="(max-width: 712px) 100vw, 712px" /></p>
<p>In the next step you choose the connection type</p>
<ul>
<li>Moment connections: beam-column, beam-beam, splice, beam-column-beam or CHS splice</li>
<li>Shear connections: beam-column or beam-beam, beam-column-beam or beam-beam-beam</li>
<li>Base plate connections</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9537 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler2.png" alt="" width="777" height="192" /></p>
<p>After selecting for example ‘Beam to column’ you select the column and next the beam element from the 3D image on the left hand side. Click once on the column element and next on the beam element. BIM Expert will list and indicate which connections are possible:</p>
<ul>
<li>Beam to column flange &gt; possible, and marked with <img decoding="async" loading="lazy" class="alignnone size-full wp-image-9559" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_check.png" alt="" width="20" height="20" /></li>
<li>Beam to column web &gt; not possible, and not marked – you can click the orange arrow <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9558 size-full" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_arrow.png" alt="" width="21" height="20" />at the end to fold out the details and see why this connection is not possible.</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9542 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png" alt="" width="350" height="348" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png 587w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-150x150.png 150w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-300x298.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-50x50.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-60x60.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-35x35.png 35w" sizes="(max-width: 350px) 100vw, 350px" /></p>
<p>On clicking ‘Create’, the connection is added to the list of connections on top. Having selected the beam-column type, you can now continue making this type of connections, until you click ‘Change pattern’.</p>
<p><img decoding="async" loading="lazy" class=" wp-image-9543 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png" alt="" width="391" height="354" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png 583w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-300x271.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-50x45.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-60x54.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-35x32.png 35w" sizes="(max-width: 391px) 100vw, 391px" /></p>
<p>When the connection definition is finished, you click ‘Close’ and ‘Accept’ to continue to PowerConnect.</p>
<p>If you have chosen to open the model directly in PowerConnect, you will get a notification in PowerConnect on the right side. You can now choose to load the model or to delete it (by using the ‘x’).</p>
<p><img decoding="async" loading="lazy" class="wp-image-9553 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png" alt="" width="403" height="160" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png 549w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-300x119.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-50x20.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-60x24.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-35x14.png 35w" sizes="(max-width: 403px) 100vw, 403px" /></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<h2 id="1-preparation-in-revit"><strong>3. Final steps in PowerConnect</strong></h2>
<p><p>All connections will appear in the node list on the left side (as from PowerConnect 2021).  Remember that all identical connections will be grouped as 1.</p>
<p>Connections made with the Connection Assembler might appear with a red bar and as &#8216;Undefined&#8217;.  The connector type must be chosen (e.g. end plate, shear plate, welded, angles etc)</p>
<p><img decoding="async" loading="lazy" class="wp-image-9555 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png" alt="" width="817" height="282" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png 1731w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-300x103.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-768x265.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-1024x353.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-50x17.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-60x21.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-35x12.png 35w" sizes="(max-width: 817px) 100vw, 817px" /></p>
<p>Click on this connection to set the connector.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9554 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png" alt="" width="765" height="284" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png 1729w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-300x111.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-768x285.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-1024x380.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-50x19.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-60x22.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-35x13.png 35w" sizes="(max-width: 765px) 100vw, 765px" /></p>
<p>If no loads or internal forces were transferred, you should add loads in PowerConnect, in order to have a proper design of the connections.<script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
<br />
<div>
<h2 id="1-preparation-in-revit" class="wp-block-heading"><strong>4. Get started with BIM Expert<br />
</strong></h2>
</div>
<div style="text-align: left;"><div class="su-button-center"><a href="https://support.buildsoft.eu" class="su-button su-button-style-flat" style="color:#FFFFFF;background-color:#E74C3C;border-color:#b93d30;border-radius:0px" target="_blank" rel="noopener noreferrer"><span style="color:#FFFFFF;padding:8px 26px;font-size:20px;line-height:30px;border-color:#ef8277;border-radius:0px;text-shadow:none"><i class="sui sui-arrow-right" style="font-size:20px;color:#FFFFFF"></i> Download your free trial of BIM Expert</span></a></div></div>
<div><div class="su-spacer" style="height:75px"></div></div>
</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>From Revit to PowerConnect</title>
		<link>https://support.buildsoft.eu/knowledge-base/from-revit-to-powerconnect/</link>
		
		<dc:creator><![CDATA[Dorothee]]></dc:creator>
		<pubDate>Mon, 22 May 2023 11:20:48 +0000</pubDate>
				<guid isPermaLink="false">https://support.buildsoft.eu/?post_type=ht_kb&#038;p=9606</guid>

					<description><![CDATA[This article explains how to send one or nodes of a Revit to PowerConnect, using BIM Expert. 1. Preparation in Revit The transfer is based on the analytical model. So in Revit, you need to create an analytical model first. You can use the Analytical Automation command in Revit or...]]></description>
										<content:encoded><![CDATA[<p>This article explains how to send one or nodes of a Revit to PowerConnect, using BIM Expert.</p>
<p><span id="more-9606"></span></p>
<h2 style="text-align: left;"><strong>1. Preparation in Revit</strong></h2>
<p>The transfer is based on the analytical model. So in Revit, you need to create an analytical model first. You can use the <em>Analytical Automation</em> command in Revit or create the analytical elements manually.&nbsp; The quality and coherence (connection between elements) of the analytical model is not relevant, as PowerConnect will only take the physical model into account.</p>
<p><div class="su-spoiler su-spoiler-style-default su-spoiler-icon-plus su-spoiler-closed" data-scroll-offset="0" data-anchor-in-url="no"><div class="su-spoiler-title" tabindex="0" role="button"><span class="su-spoiler-icon"></span>Creating the analytical model fast (no quality demand)</div><div class="su-spoiler-content su-u-clearfix su-u-trim"></p>
<h3>1.1 Analytical Automation</h3>
<p>The <em>Analytical Automation</em> will work only for &#8216;structural important&#8217; elements, like columns, beams, floors and walls. It will not work for landscaping or curtains. This filtrage can be an advantage and save you time.</p>
<p><img decoding="async" loading="lazy" class=" wp-image-9035 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalautomation.png" alt="" width="506" height="114" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalautomation.png 692w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalautomation-300x68.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalautomation-50x11.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalautomation-60x14.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalautomation-35x8.png 35w" sizes="(max-width: 506px) 100vw, 506px" />Once the <em>Analytical Automation</em> dialog pops up, you choose &#8216;Physical to Analytical&#8217;, by clicking the play button.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9080 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalmanual_pa_ap_pa.png" alt="" width="390" height="230" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalmanual_pa_ap_pa.png 577w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalmanual_pa_ap_pa-300x177.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalmanual_pa_ap_pa-50x29.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalmanual_pa_ap_pa-60x35.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalmanual_pa_ap_pa-35x21.png 35w" sizes="(max-width: 390px) 100vw, 390px" /></p>
<p>Select the elements in the model (attention: the selection process must be in 1 go) and click &#8216;Run&#8217; to generate the model with default settings.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9043 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalautomation_pa.png" alt="" width="310" height="382" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalautomation_pa.png 581w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalautomation_pa-243x300.png 243w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalautomation_pa-41x50.png 41w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalautomation_pa-49x60.png 49w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalautomation_pa-28x35.png 28w" sizes="(max-width: 310px) 100vw, 310px" /></p>
<h3>1.2 Manually create analytical elements</h3>
<p>It is not time-efficient to manually build an analytical model from scratch. It is is only recommended if there are elements missing after running the <em>Analytical Automation</em> command.</p>
<p><img decoding="async" loading="lazy" class=" wp-image-9036 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalmanual.png" alt="" width="498" height="109" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalmanual.png 699w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalmanual-300x66.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalmanual-50x11.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalmanual-60x13.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_analyticalmanual-35x8.png 35w" sizes="(max-width: 498px) 100vw, 498px" /></p>
<p>After you have created new analytical elements, you need to associate them with their physical counterpart. You could also opt to use the <em>Assisted Association</em>&nbsp;command which creates the link while you are drawing the analytical element.<img decoding="async" loading="lazy" class="wp-image-9038 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_assistedassociation.png" alt="" width="415" height="99" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_assistedassociation.png 632w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_assistedassociation-300x72.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_assistedassociation-50x12.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_assistedassociation-60x14.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_assistedassociation-35x8.png 35w" sizes="(max-width: 415px) 100vw, 415px" /></p>
<p></div></div></p>
<h2><strong>2.&nbsp; Send the Revit model to PowerConnect<br />
</strong></h2>
<h3>2.1 From Revit to BIM Expert</h3>
<p><p>There are 2 ways to send models from Revit to BIM Expert:</p>
<ol>
<li>Starting in Revit: in the BIM Expert tab page, select &#8216;Export&#8217;.<br />
<img decoding="async" loading="lazy" class="wp-image-9040 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_bimexpertexport.png" alt="" width="633" height="82" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_bimexpertexport.png 1218w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_bimexpertexport-300x39.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_bimexpertexport-768x100.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_bimexpertexport-1024x133.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_bimexpertexport-50x6.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_bimexpertexport-60x8.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_bimexpertexport-35x5.png 35w" sizes="(max-width: 633px) 100vw, 633px" /></li>
<li style="text-align: left;">Starting in BIM Expert: click &#8216;Model &gt; Import&#8217; and select the Revit plugin. In case you have multiple Revit models open, BIM Expert will ask to select your model to be transferred.<br />
<img decoding="async" loading="lazy" class="aligncenter wp-image-9087" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_fromrevit_import_modeloverview.png" alt="" width="638" height="239" /></li>
</ol>
<p>No matter the way you have chosen, BIM Expert will now take over.</p>
<h4>2.1.1 Settings</h4>
<p>You can have all (or a selection of) analytical elements exported. All elements is the most likely option.</p>
<p><img decoding="async" loading="lazy" class=" wp-image-9047 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exporttobimexpert.png" alt="" width="221" height="295" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exporttobimexpert.png 382w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exporttobimexpert-225x300.png 225w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exporttobimexpert-38x50.png 38w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exporttobimexpert-45x60.png 45w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exporttobimexpert-26x35.png 26w" sizes="(max-width: 221px) 100vw, 221px" /></p>
<p>Next, the Revit sections and materials must be mapped with BIM Expert&#8217;s section and material database. BIM Expert will try to find as many automatic mapping matches as possible. In case all sections and materials find a match, you will not see any dialogs for mapping.</p>
<h4>2.1.2 Material mapping</h4>
<p>Database materials such as steel (e.g. S235, ASTM-Grades), concrete (e.g. C25/30, M50) and timber (e.g. C24, D50, GL28c) are mapped automatically. In some cases, the match is not automatically found, because the name differs (<em>Concrete grade C25</em> instead of <em>Concrete grade C25/30</em>). In that case, you can select the correct material from the database.</p>
<p><em>Tip: When searching an item in the database, type the first letters of the name to find it more quickly.</em></p>
<p><img decoding="async" loading="lazy" class="wp-image-9052 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exportmaterialmatch.png" alt="" width="483" height="307" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exportmaterialmatch.png 698w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exportmaterialmatch-300x191.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exportmaterialmatch-50x32.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exportmaterialmatch-60x38.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exportmaterialmatch-35x22.png 35w" sizes="(max-width: 483px) 100vw, 483px" /></p>
<p>If you cannot find a suited counterpart in the BIM Expert database, the material can be added as new.</p>
<h4>2.1.3 Section mapping</h4>
<p>Database sections (such as I, H, UB, UC, W, C, U, O, ☐ and L sections) are mapped automatically. In some cases, the match is not automatically found, because the name differs  (e.g. name is <em>HEB300 &#8211; S235</em> instead of <em>HEB300</em>). In that case, you can select the correct cross-section from the database.<br />
<em>Tip: When searching an item in the database, type the first letters of the name to find it more quickly.</em></p>
<p>Parametric sections (e.g. rectangles, circle, trapezium, &#8230;) are not in the database. They should always be added as new.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9054 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exportsectionmatch.png" alt="" width="567" height="328" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exportsectionmatch.png 951w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exportsectionmatch-300x174.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exportsectionmatch-768x444.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exportsectionmatch-50x29.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exportsectionmatch-60x35.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_revit_exportsectionmatch-35x20.png 35w" sizes="(max-width: 567px) 100vw, 567px" /></p>
<p>The model is now in BIM Expert.</p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<h3 id="2-2-from-bim-expert-to-tekla-structures">2.2 From BIM Expert to PowerConnect</h3>
<p><p>In the Model tab, select ‘Export’. Next, choose the destination software, namely PowerConnect. Click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" sizes="(max-width: 29px) 100vw, 29px" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" alt="" width="29" height="28" /> to continue.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9530 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png" alt="" width="397" height="241" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png 602w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-300x182.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-50x30.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-60x36.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-35x21.png 35w" sizes="(max-width: 397px) 100vw, 397px" /></p>
<h4 id="2-2-1-settings">2.2.1 Settings</h4>
<p>You can choose to either</p>
<ul>
<li>save the model as *.bpc-file</li>
<li>send the model to the current open PowerConnect instance &#8211; you see all open instances of PowerConnect</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9533 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png" alt="" width="564" height="152" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png 735w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-300x81.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-50x13.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-60x16.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-35x9.png 35w" sizes="(max-width: 564px) 100vw, 564px" /></p>
<p>Select your choice and click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" alt="" width="29" height="28" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" sizes="(max-width: 29px) 100vw, 29px" /> to continue.</p>
<h5>2.2.2 Automatic detection of connection components</h5>
<p>BIM Expert automatically detects existing connection components in the model. You get an overview of all found connection components and whether they can be transferred to PowerConnect.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9569 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png" alt="" width="790" height="349" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png 1654w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-300x132.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-768x339.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-1024x452.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-50x22.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-60x26.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-35x15.png 35w" sizes="(max-width: 790px) 100vw, 790px" /></p>
<p>&nbsp;</p>
<p>Use the eye button in the &#8216;Show&#8217; column to see a detailed popup window of the connection.</p>
<p>Possible descriptions are</p>
<ul>
<li><em>Some internal forces could not be retrieved from the analysis results</em><br />
No (or not all) internal forces are present from the source software.</li>
<li><em>The connection is identical to connection(s) {IDs} and therefore has been grouped</em><br />
Identical connections will be treated as one connection. You must only calculate the connections one, with envelope forces.</li>
<li><em>Connection merged with one or more parts of the following connection: {ID}</em><br />
The connection is merged with other one to create a more complex connection (e.g. two shear connections to beam-column are merged to design a double-sided shear connection)</li>
<li><em>Connection divided into &lt;&#8230;.&gt; connections </em><br />
A complex connection has been split up into smaller PowerConnect connections</li>
<li><em>The connection bars/plates with following ID&#8217;s could not be recognized: {IDs} </em><br />
The connection is recognized and can be calculated with PowerConnect, execpt for these bars/plates, with given Ids</li>
<li><em>Connection type not support</em><br />
This connection configuration cannot be calculated by PowerConnect, so it will not be transferred.</li>
</ul>
<p>If no connections are found, you will see</p>
<p><img decoding="async" loading="lazy" class="wp-image-9573 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png" alt="" width="381" height="223" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png 538w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-300x176.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-50x29.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-60x35.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-35x20.png 35w" sizes="(max-width: 381px) 100vw, 381px" /></p>
<h4>2.2.3 Add connections manually via Connection Assembler</h4>
<p>You can make your own connections by clicking ‘Modify’ (see image above).</p>
<p>In the next window, you see on the left hand side the BIM Expert model. In this window you see the regular scroll, 3D orbit and pan functions. On the right hand side, there is on top an overview of created connections and at the bottom, the &#8216;Create&#8217; button to make new connections.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9546 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png" alt="" width="712" height="356" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png 1553w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-300x150.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-768x384.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-1024x512.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-50x25.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-60x30.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-35x18.png 35w" sizes="(max-width: 712px) 100vw, 712px" /></p>
<p>In the next step you choose the connection type</p>
<ul>
<li>Moment connections: beam-column, beam-beam, splice, beam-column-beam or CHS splice</li>
<li>Shear connections: beam-column or beam-beam, beam-column-beam or beam-beam-beam</li>
<li>Base plate connections</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9537 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler2.png" alt="" width="777" height="192" /></p>
<p>After selecting for example ‘Beam to column’ you select the column and next the beam element from the 3D image on the left hand side. Click once on the column element and next on the beam element. BIM Expert will list and indicate which connections are possible:</p>
<ul>
<li>Beam to column flange &gt; possible, and marked with <img decoding="async" loading="lazy" class="alignnone size-full wp-image-9559" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_check.png" alt="" width="20" height="20" /></li>
<li>Beam to column web &gt; not possible, and not marked – you can click the orange arrow <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9558 size-full" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_arrow.png" alt="" width="21" height="20" />at the end to fold out the details and see why this connection is not possible.</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9542 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png" alt="" width="350" height="348" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png 587w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-150x150.png 150w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-300x298.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-50x50.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-60x60.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-35x35.png 35w" sizes="(max-width: 350px) 100vw, 350px" /></p>
<p>On clicking ‘Create’, the connection is added to the list of connections on top. Having selected the beam-column type, you can now continue making this type of connections, until you click ‘Change pattern’.</p>
<p><img decoding="async" loading="lazy" class=" wp-image-9543 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png" alt="" width="391" height="354" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png 583w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-300x271.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-50x45.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-60x54.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-35x32.png 35w" sizes="(max-width: 391px) 100vw, 391px" /></p>
<p>When the connection definition is finished, you click ‘Close’ and ‘Accept’ to continue to PowerConnect.</p>
<p>If you have chosen to open the model directly in PowerConnect, you will get a notification in PowerConnect on the right side. You can now choose to load the model or to delete it (by using the ‘x’).</p>
<p><img decoding="async" loading="lazy" class="wp-image-9553 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png" alt="" width="403" height="160" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png 549w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-300x119.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-50x20.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-60x24.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-35x14.png 35w" sizes="(max-width: 403px) 100vw, 403px" /></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<h2 id="1-preparation-in-revit"><strong>3. Final steps in PowerConnect</strong></h2>
<p><p>All connections will appear in the node list on the left side (as from PowerConnect 2021).  Remember that all identical connections will be grouped as 1.</p>
<p>Connections made with the Connection Assembler might appear with a red bar and as &#8216;Undefined&#8217;.  The connector type must be chosen (e.g. end plate, shear plate, welded, angles etc)</p>
<p><img decoding="async" loading="lazy" class="wp-image-9555 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png" alt="" width="817" height="282" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png 1731w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-300x103.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-768x265.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-1024x353.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-50x17.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-60x21.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-35x12.png 35w" sizes="(max-width: 817px) 100vw, 817px" /></p>
<p>Click on this connection to set the connector.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9554 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png" alt="" width="765" height="284" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png 1729w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-300x111.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-768x285.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-1024x380.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-50x19.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-60x22.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-35x13.png 35w" sizes="(max-width: 765px) 100vw, 765px" /></p>
<p>If no loads or internal forces were transferred, you should add loads in PowerConnect, in order to have a proper design of the connections.<script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<p>&nbsp;</p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<p><div>
<h2 id="1-preparation-in-revit" class="wp-block-heading"><strong>4. Get started with BIM Expert<br />
</strong></h2>
</div>
<div style="text-align: left;"><div class="su-button-center"><a href="https://support.buildsoft.eu" class="su-button su-button-style-flat" style="color:#FFFFFF;background-color:#E74C3C;border-color:#b93d30;border-radius:0px" target="_blank" rel="noopener noreferrer"><span style="color:#FFFFFF;padding:8px 26px;font-size:20px;line-height:30px;border-color:#ef8277;border-radius:0px;text-shadow:none"><i class="sui sui-arrow-right" style="font-size:20px;color:#FFFFFF"></i> Download your free trial of BIM Expert</span></a></div></div>
<div><div class="su-spacer" style="height:75px"></div></div>
</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>From ETABS to PowerConnect</title>
		<link>https://support.buildsoft.eu/knowledge-base/from-etabs-to-powerconnect/</link>
		
		<dc:creator><![CDATA[Dorothee]]></dc:creator>
		<pubDate>Mon, 22 May 2023 10:44:49 +0000</pubDate>
				<guid isPermaLink="false">https://support.buildsoft.eu/?post_type=ht_kb&#038;p=9601</guid>

					<description><![CDATA[This article explains how to send one or more ETABS nodes to PowerConnect, using BIM Expert. 1. Preparation in ETABS Make sure the model is calculated and that elastic results are available. 2. Send the ETABS model to PowerConnect 2.1 From ETABS to BIM Expert 2.2 From BIM Expert to...]]></description>
										<content:encoded><![CDATA[<p>This article explains how to send one or more ETABS nodes to PowerConnect, using BIM Expert.</p>
<p><span id="more-9601"></span></p>
<h2 id="1-preparation-in-revit"><strong>1. Preparation in ETABS</strong></h2>
<p>Make sure the model is calculated and that elastic results are available.</p>
<h2 id="2-send-the-revit-model-to-tekla-structures"><strong>2. Send the ETABS model to PowerConnect<br /></strong></h2>
<h3 id="2-1-from-revit-to-bim-expert">2.1 From ETABS to BIM Expert</h3>
<p><p>In the Model tab, select ‘Import’. Next, choose the source software manufacturer, namely &#8216;Computer and Structures, Inc&#8217; (CSI) . Click <img decoding="async" loading="lazy" class="img_inline wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" width="29" height="28" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" sizes="(max-width: 29px) 100vw, 29px" /> to continue.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9335 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi.png" alt="" width="237" height="229" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi.png 378w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi-300x290.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi-50x48.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi-60x58.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi-35x35.png 35w" sizes="(max-width: 237px) 100vw, 237px" /></p>
<p>Choose &#8216;ETABS&#8217;.<br />
<img decoding="async" loading="lazy" class="wp-image-9388 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs.png" alt="" width="332" height="144" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs.png 441w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs-300x130.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs-50x22.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs-60x26.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs-35x15.png 35w" sizes="(max-width: 332px) 100vw, 332px" /></p>
<p>Alternatively, models can be sent to BIM Expert directly within ETABS (Tools &gt; BIM Expert), but you first need to add BIM Expert as a plug-in to ETABS.</p>
<p><div class="su-spoiler su-spoiler-style-default su-spoiler-icon-plus su-spoiler-closed" data-scroll-offset="0" data-anchor-in-url="no"><div class="su-spoiler-title" tabindex="0" role="button"><span class="su-spoiler-icon"></span>How to add BIM Expert as plugin in ETABS</div><div class="su-spoiler-content su-u-clearfix su-u-trim"></p>
<ol>
<li>Tools &gt; Add/Show plugins</li>
<li>Click &#8216;Browse&#8217; to locate the BIM Expert ETABS dll
<ul>
<li>Go to C:\Program Files (x86)\BuildSoft\BIM Expert\Plugins\CSI\</li>
<li>Select the dll <em>ETABS{version}PlugInBuildSoftBIMExpert.dll, </em>with <em>{version}</em> according to your current ETABS version open (e.g. ETABSv20PlugInBuildSoftBIMExpert.dll)</li>
<li>Click &#8216;Open&#8217;</li>
</ul>
</li>
<li>Change the Menu Text name to &#8216;BIM Expert&#8217;</li>
<li>Click &#8216;Add&#8217; to add the plugin&#8217; &amp; &#8216;Ok&#8217;</li>
<li>BIM Expert is now in the Tools menu</li>
</ol>
<p></div></div></p>
<h4>2.2.1 Settings</h4>
<p><img decoding="async" loading="lazy" class="wp-image-9392 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_options.png" alt="" width="425" height="370" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_options.png 620w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_options-300x261.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_options-50x44.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_options-60x52.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_options-35x30.png 35w" sizes="(max-width: 425px) 100vw, 425px" /></p>
<p>Select your ETABS version, and were the model is coming from:</p>
<ul>
<li>A running instance &#8211; that means, the model is currently open in ETABS</li>
<li>An existing model &#8211; click &#8216;Browse&#8230; &#8216; to open your file browser, go to the model location and select the model (an .edb file)</li>
</ul>
<p>    		<div class="hts-messages hts-messages--alert  hts-messages--withtitle hts-messages--withicon " id="" style="">
    			<span class="hts-messages__title">License required</span>    			    				<p>
    					A valid ETABS license is required in both cases, that is importing from the running instance as well as opening an existing model.    				</p>
    			    			
    		</div><!-- /.ht-shortcodes-messages -->
    		</p>
<p>On top of the geometry conversion, you can also consider loads and results in points, bars &amp; plates.  Bar results are the most used and relevant ones, so only considering the bar results is enough. Plate results can be huge amount of data, that is currently not used any further.</p>
<p>Next, the ETABS material and sections must be mapped with BIM Expert &#8216;s materials and section. BIM Expert will try to find as many automatic mapping matches as possible. In case all sections and materials find a match, you will not see any dialogs for mapping.</p>
<h4 id="2-1-2-material-mapping">2.2.2 Material mapping</h4>
<p>Database materials such as steel (e.g. S235, ASTM-Grades), concrete (e.g. C25/30, M50) and timber (e.g. C24, D50, GL28c) are mapped automatically. In some cases, the match is not automatically found, because the name differs (<em>S355-link</em> instead of <em>S355</em>). In that case, you can select the correct material from the database.</p>
<p><em>Tip: When searching an item in the database, type the first letters of the name to find it more quickly.</em></p>
<p><img decoding="async" loading="lazy" class="wp-image-9418 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_materialmapping.png" alt="" width="720" height="237" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_materialmapping.png 1125w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_materialmapping-300x99.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_materialmapping-768x253.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_materialmapping-1024x337.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_materialmapping-50x16.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_materialmapping-60x20.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_materialmapping-35x12.png 35w" sizes="(max-width: 720px) 100vw, 720px" /></p>
<h4 id="2-1-3-section-mapping">2.1.3 Section mapping</h4>
<p>Database sections (such as I, H, UB, UC, W, C, U, O, ☐ and L sections) are mapped automatically. In some cases, the match is not automatically found, because the name differs  (e.g. name is <em>HEB300 &#8211; S235</em> instead of <em>HEB300</em>). In that case, you can select the correct cross-section from the database.<br />
<em>Tip: When searching an item in the database, type the first letters of the name to find it more quickly.</em></p>
<p>Parametric sections (e.g. rectangles, circle, trapezium, &#8230;) are not in the database. They should always be added as new.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9398 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_sectionmapping.png" alt="" width="642" height="321" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_sectionmapping.png 1125w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_sectionmapping-300x150.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_sectionmapping-768x384.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_sectionmapping-1024x512.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_sectionmapping-50x25.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_sectionmapping-60x30.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_sectionmapping-35x18.png 35w" sizes="(max-width: 642px) 100vw, 642px" /></p>
<h4>2.1.4 Loads mapping</h4>
<p>If you opted to consider the loads during export, the ETABS load combinations need to be categorized. Each valid ETABS combination must be categorized into Eurocode or American combinations. Use the checkbox &#8216;Use categories according to Limit States&#8217; to switch between European and American combination categories.</p>
<p><div class="su-row"><div class="su-column su-column-size-3-5"><div class="su-column-inner su-u-clearfix su-u-trim"><img decoding="async" loading="lazy" class="alignnone wp-image-9407" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_loads_EC.png" alt="" width="864" height="414" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_loads_EC.png 1176w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_loads_EC-300x144.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_loads_EC-768x368.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_loads_EC-1024x490.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_loads_EC-50x24.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_loads_EC-60x29.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_loads_EC-35x17.png 35w" sizes="(max-width: 864px) 100vw, 864px" /></div></div><br />
<div class="su-column su-column-size-2-5"><div class="su-column-inner su-u-clearfix su-u-trim"><img decoding="async" loading="lazy" class="alignnone wp-image-9406" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_loads_USA.png" alt="" width="601" height="502" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_loads_USA.png 674w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_loads_USA-300x251.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_loads_USA-50x42.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_loads_USA-60x50.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_loads_USA-35x29.png 35w" sizes="(max-width: 601px) 100vw, 601px" /></div></div></div></p>
<p>Depending on the design code, you must map each combination with either</p>
<ul>
<li>Eurocode Limit States
<ul>
<li>ULS &#8211; Ultimate Limit State Combinations: Fundamental (FC), Seismic (SC), Fire (FI) or Accidental (AC)</li>
<li>SLS &#8211; Serviceability Limit State Combinations: Rare (RC), Frequent (FC) or Quasi-Permanent (QP)</li>
<li>Custom</li>
</ul>
</li>
<li>American
<ul>
<li>Strength</li>
<li>Service</li>
<li>Custom</li>
</ul>
</li>
</ul>
<p>On hoovering with the mouse over the combination&#8217;s name, you can see the build up of the combination (e.g. 1.35 DL + 1.50 LL).</p>
<p>Use SHIFT and CTRL commands as in Windows to select one or multiple items. For example, to select all, use &#8216;CTRL+A&#8217; and then, select the &#8220;+&#8221; button in the corresponding column.</p>
<p>Envelope combinations and dynamic seismic combinations are cannot be matched, as this is not supported by BIM Expert. These types of combinations are considered non-valid and will be greyed out. Static seismic combinations can be mapped.</p>
<p>Remark: If you cancel that load mapping dialog, combinations are neglected and the conversion proceeds.</p>
<h4>2.1.5 Reporting</h4>
<p>In case of severe incidences, you get a report of the incidences. It usually concerns load cases or element behavior that are not supported by BIM Expert. Click &#8216;Continue&#8217; to proceed anyway.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9397 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_reportincidences.png" alt="" width="565" height="384" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_reportincidences.png 937w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_reportincidences-300x205.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_reportincidences-768x524.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_reportincidences-50x34.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_reportincidences-60x41.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_reportincidences-35x24.png 35w" sizes="(max-width: 565px) 100vw, 565px" /></p>
<p>The model is now in BIM Expert.</p>
</p>
<h3 id="2-2-from-bim-expert-to-tekla-structures">2.2 From BIM Expert to PowerConnect</h3>
<p><p>In the Model tab, select ‘Export’. Next, choose the destination software, namely PowerConnect. Click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" sizes="(max-width: 29px) 100vw, 29px" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" alt="" width="29" height="28" /> to continue.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9530 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png" alt="" width="397" height="241" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png 602w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-300x182.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-50x30.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-60x36.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-35x21.png 35w" sizes="(max-width: 397px) 100vw, 397px" /></p>
<h4 id="2-2-1-settings">2.2.1 Settings</h4>
<p>You can choose to either</p>
<ul>
<li>save the model as *.bpc-file</li>
<li>send the model to the current open PowerConnect instance &#8211; you see all open instances of PowerConnect</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9533 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png" alt="" width="564" height="152" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png 735w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-300x81.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-50x13.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-60x16.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-35x9.png 35w" sizes="(max-width: 564px) 100vw, 564px" /></p>
<p>Select your choice and click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" alt="" width="29" height="28" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" sizes="(max-width: 29px) 100vw, 29px" /> to continue.</p>
<h5>2.2.2 Automatic detection of connection components</h5>
<p>BIM Expert automatically detects existing connection components in the model. You get an overview of all found connection components and whether they can be transferred to PowerConnect.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9569 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png" alt="" width="790" height="349" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png 1654w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-300x132.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-768x339.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-1024x452.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-50x22.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-60x26.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-35x15.png 35w" sizes="(max-width: 790px) 100vw, 790px" /></p>
<p>&nbsp;</p>
<p>Use the eye button in the &#8216;Show&#8217; column to see a detailed popup window of the connection.</p>
<p>Possible descriptions are</p>
<ul>
<li><em>Some internal forces could not be retrieved from the analysis results</em><br />
No (or not all) internal forces are present from the source software.</li>
<li><em>The connection is identical to connection(s) {IDs} and therefore has been grouped</em><br />
Identical connections will be treated as one connection. You must only calculate the connections one, with envelope forces.</li>
<li><em>Connection merged with one or more parts of the following connection: {ID}</em><br />
The connection is merged with other one to create a more complex connection (e.g. two shear connections to beam-column are merged to design a double-sided shear connection)</li>
<li><em>Connection divided into &lt;&#8230;.&gt; connections </em><br />
A complex connection has been split up into smaller PowerConnect connections</li>
<li><em>The connection bars/plates with following ID&#8217;s could not be recognized: {IDs} </em><br />
The connection is recognized and can be calculated with PowerConnect, execpt for these bars/plates, with given Ids</li>
<li><em>Connection type not support</em><br />
This connection configuration cannot be calculated by PowerConnect, so it will not be transferred.</li>
</ul>
<p>If no connections are found, you will see</p>
<p><img decoding="async" loading="lazy" class="wp-image-9573 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png" alt="" width="381" height="223" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png 538w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-300x176.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-50x29.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-60x35.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-35x20.png 35w" sizes="(max-width: 381px) 100vw, 381px" /></p>
<h4>2.2.3 Add connections manually via Connection Assembler</h4>
<p>You can make your own connections by clicking ‘Modify’ (see image above).</p>
<p>In the next window, you see on the left hand side the BIM Expert model. In this window you see the regular scroll, 3D orbit and pan functions. On the right hand side, there is on top an overview of created connections and at the bottom, the &#8216;Create&#8217; button to make new connections.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9546 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png" alt="" width="712" height="356" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png 1553w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-300x150.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-768x384.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-1024x512.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-50x25.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-60x30.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-35x18.png 35w" sizes="(max-width: 712px) 100vw, 712px" /></p>
<p>In the next step you choose the connection type</p>
<ul>
<li>Moment connections: beam-column, beam-beam, splice, beam-column-beam or CHS splice</li>
<li>Shear connections: beam-column or beam-beam, beam-column-beam or beam-beam-beam</li>
<li>Base plate connections</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9537 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler2.png" alt="" width="777" height="192" /></p>
<p>After selecting for example ‘Beam to column’ you select the column and next the beam element from the 3D image on the left hand side. Click once on the column element and next on the beam element. BIM Expert will list and indicate which connections are possible:</p>
<ul>
<li>Beam to column flange &gt; possible, and marked with <img decoding="async" loading="lazy" class="alignnone size-full wp-image-9559" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_check.png" alt="" width="20" height="20" /></li>
<li>Beam to column web &gt; not possible, and not marked – you can click the orange arrow <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9558 size-full" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_arrow.png" alt="" width="21" height="20" />at the end to fold out the details and see why this connection is not possible.</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9542 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png" alt="" width="350" height="348" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png 587w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-150x150.png 150w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-300x298.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-50x50.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-60x60.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-35x35.png 35w" sizes="(max-width: 350px) 100vw, 350px" /></p>
<p>On clicking ‘Create’, the connection is added to the list of connections on top. Having selected the beam-column type, you can now continue making this type of connections, until you click ‘Change pattern’.</p>
<p><img decoding="async" loading="lazy" class=" wp-image-9543 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png" alt="" width="391" height="354" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png 583w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-300x271.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-50x45.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-60x54.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-35x32.png 35w" sizes="(max-width: 391px) 100vw, 391px" /></p>
<p>When the connection definition is finished, you click ‘Close’ and ‘Accept’ to continue to PowerConnect.</p>
<p>If you have chosen to open the model directly in PowerConnect, you will get a notification in PowerConnect on the right side. You can now choose to load the model or to delete it (by using the ‘x’).</p>
<p><img decoding="async" loading="lazy" class="wp-image-9553 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png" alt="" width="403" height="160" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png 549w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-300x119.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-50x20.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-60x24.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-35x14.png 35w" sizes="(max-width: 403px) 100vw, 403px" /></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<h2 id="1-preparation-in-revit"><strong>3. Final steps in PowerConnect</strong></h2>
<p><p>All connections will appear in the node list on the left side (as from PowerConnect 2021).  Remember that all identical connections will be grouped as 1.</p>
<p>Connections made with the Connection Assembler might appear with a red bar and as &#8216;Undefined&#8217;.  The connector type must be chosen (e.g. end plate, shear plate, welded, angles etc)</p>
<p><img decoding="async" loading="lazy" class="wp-image-9555 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png" alt="" width="817" height="282" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png 1731w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-300x103.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-768x265.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-1024x353.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-50x17.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-60x21.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-35x12.png 35w" sizes="(max-width: 817px) 100vw, 817px" /></p>
<p>Click on this connection to set the connector.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9554 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png" alt="" width="765" height="284" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png 1729w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-300x111.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-768x285.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-1024x380.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-50x19.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-60x22.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-35x13.png 35w" sizes="(max-width: 765px) 100vw, 765px" /></p>
<p>If no loads or internal forces were transferred, you should add loads in PowerConnect, in order to have a proper design of the connections.<script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<p><div>
<h2 id="1-preparation-in-revit" class="wp-block-heading"><strong>4. Get started with BIM Expert<br />
</strong></h2>
</div>
<div style="text-align: left;"><div class="su-button-center"><a href="https://support.buildsoft.eu" class="su-button su-button-style-flat" style="color:#FFFFFF;background-color:#E74C3C;border-color:#b93d30;border-radius:0px" target="_blank" rel="noopener noreferrer"><span style="color:#FFFFFF;padding:8px 26px;font-size:20px;line-height:30px;border-color:#ef8277;border-radius:0px;text-shadow:none"><i class="sui sui-arrow-right" style="font-size:20px;color:#FFFFFF"></i> Download your free trial of BIM Expert</span></a></div></div>
<div><div class="su-spacer" style="height:75px"></div></div>
</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>From SAP2000 to PowerConnect</title>
		<link>https://support.buildsoft.eu/knowledge-base/from-sap2000-to-powerconnect/</link>
		
		<dc:creator><![CDATA[Dorothee]]></dc:creator>
		<pubDate>Mon, 22 May 2023 10:40:05 +0000</pubDate>
				<guid isPermaLink="false">https://support.buildsoft.eu/?post_type=ht_kb&#038;p=9597</guid>

					<description><![CDATA[This article explains how to send one or more SAP2000 nodes to PowerConnect, using BIM Expert. 1. Preparation in SAP2000 Make sure the model is calculated and that elastic results are available. 2. Send model from SAP2000 to PowerConnect 2.1 From SAP2000 to BIM Expert 2.2 From BIM Expert to...]]></description>
										<content:encoded><![CDATA[<p>This article explains how to send one or more SAP2000 nodes to PowerConnect, using BIM Expert.</p>
<p><span id="more-9597"></span></p>
<h2 style="text-align: left;"><strong>1. Preparation in SAP2000</strong></h2>
<p>Make sure the model is calculated and that elastic results are available.</p>
<h2 id="1-preparation-in-revit"><strong>2. Send model from SAP2000 to PowerConnect</strong></h2>
<h3>2.1 From SAP2000 to BIM Expert</h3>
<p><p>In the Model tab, select ‘Import’. Next, choose the source software manufacturer, namely &#8216;Computer and Structures, Inc&#8217; (CSI) . Click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" sizes="(max-width: 29px) 100vw, 29px" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" alt="" width="29" height="28" /> to continue.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9335 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi.png" alt="" width="237" height="229" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi.png 378w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi-300x290.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi-50x48.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi-60x58.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi-35x35.png 35w" sizes="(max-width: 237px) 100vw, 237px" /></p>
<p>Choose &#8216;SAP2000&#8217;</p>
<p><img decoding="async" loading="lazy" class="wp-image-9336 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap.png" alt="" width="335" height="145" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap.png 441w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap-300x130.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap-50x22.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap-60x26.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap-35x15.png 35w" sizes="(max-width: 335px) 100vw, 335px" /></p>
<p>Alternatively, models can be sent to BIM Expert directly within SAP2000 (Tools &gt; BIM Expert), but you first need to add BIM Expert as a plug-in to SAP2000.</p>
<p><div class="su-spoiler su-spoiler-style-default su-spoiler-icon-plus su-spoiler-closed" data-scroll-offset="0" data-anchor-in-url="no"><div class="su-spoiler-title" tabindex="0" role="button"><span class="su-spoiler-icon"></span>How to add BIM Expert as plugin in SAP2000</div><div class="su-spoiler-content su-u-clearfix su-u-trim"></p>
<ol>
<li>Tools &gt; Add/Show plugins</li>
<li>Click &#8216;Browse&#8217; to locate the BIM Expert SAP2000 dll
<ul>
<li>Go to C:\Program Files (x86)\BuildSoft\BIM Expert\Plugins\CSI\</li>
<li>Select the dll SAP2000{version}PlugInBuildSoftBIMExpert.dll, with {version} according to your current SAP2000 version open (e.g. SAP2000v24PlugInBuildSoftBIMExpert.dll)</li>
<li>Click &#8216;Open&#8217;</li>
</ul>
</li>
<li>Change the Menu Text name to &#8216;BIM Expert&#8217;</li>
<li>Click &#8216;Add&#8217; to add the plugin&#8217; &amp; &#8216;Ok&#8217;</li>
<li>BIM Expert is now in the Tools menu</li>
</ol>
<p></div></div></p>
<h4>2.2.1 Settings</h4>
<p><img decoding="async" loading="lazy" class="wp-image-9337 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_options.png" alt="" width="396" height="363" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_options.png 620w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_options-300x275.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_options-50x46.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_options-60x55.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_options-35x32.png 35w" sizes="(max-width: 396px) 100vw, 396px" /></p>
<p>Select your SAP2000 version, and were the model is coming from:</p>
<ul>
<li>A running instance &#8211; that means, the model is currently open in SAP2000</li>
<li>An existing model &#8211; click &#8216;Browse&#8230; &#8216; to open your file browser, go to the model location and select the model</li>
</ul>
<p>    		<div class="hts-messages hts-messages--alert  hts-messages--withtitle hts-messages--withicon " id="" style="">
    			<span class="hts-messages__title">License required</span>    			    				<p>
    					A valid SAP2000 license is required in both cases, that is importing from the running instance as well as opening an existing model.    				</p>
    			    			
    		</div><!-- /.ht-shortcodes-messages -->
    		</p>
<p>On top of the geometry conversion, you can also consider loads and results in points, bars &amp; plates.  Bar results are the most used and relevant ones, so only considering the bar results is enough. Plate results can be huge amount of data, that is currently not used any further.</p>
<p>Next, the SAP2000 material and sections must be mapped with BIM Expert &#8216;s materials and section. BIM Expert will try to find as many automatic mapping matches as possible. In case all sections and materials find a match, you will not see any dialogs for mapping.</p>
<h4 id="2-1-2-material-mapping">2.2.2 Material mapping</h4>
<p>Database materials such as steel (e.g. S235, ASTM-Grades), concrete (e.g. C25/30, M50) and timber (e.g. C24, D50, GL28c) are mapped automatically. In some cases, the match is not automatically found, because the name differs (<em>S355-link</em> instead of <em>S355</em>). In that case, you can select the correct material from the database.</p>
<p><em>Tip: When searching an item in the database, type the first letters of the name to find it more quickly.</em></p>
<p><img decoding="async" loading="lazy" class="wp-image-9338 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_materialmapping.png" alt="" width="720" height="235" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_materialmapping.png 1115w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_materialmapping-300x98.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_materialmapping-768x251.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_materialmapping-1024x334.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_materialmapping-50x16.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_materialmapping-60x20.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_materialmapping-35x11.png 35w" sizes="(max-width: 720px) 100vw, 720px" /></p>
<h4 id="2-1-3-section-mapping">2.1.3 Section mapping</h4>
<p>Database sections (such as I, H, UB, UC, W, C, U, O, ☐ and L sections) are mapped automatically. In some cases, the match is not automatically found, because the name differs  (e.g. name is <em>HEB300 &#8211; S235</em> instead of <em>HEB300</em>). In that case, you can select the correct cross-section from the database.<br />
<em>Tip: When searching an item in the database, type the first letters of the name to find it more quickly.</em></p>
<p>Parametric sections (e.g. rectangles, circle, trapezium, &#8230;) are not in the database. They should always be added as new.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9341 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_sectionmapping.png" alt="" width="632" height="337" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_sectionmapping.png 1125w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_sectionmapping-300x160.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_sectionmapping-768x410.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_sectionmapping-1024x546.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_sectionmapping-50x27.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_sectionmapping-60x32.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_sectionmapping-35x19.png 35w" sizes="(max-width: 632px) 100vw, 632px" /></p>
<h4>2.1.4 Loads mapping</h4>
<p>If you opted to consider the loads during export, the SAP2000 load combinations need to be categorized. Each valid SAP2000 combination must be categorized into Eurocode or American combinations. Use the checkbox &#8216;Use categories according to Limit States&#8217; to switch between European and American combination categories.</p>
<p><div class="su-row"><div class="su-column su-column-size-3-5"><div class="su-column-inner su-u-clearfix su-u-trim"><br />
<img decoding="async" loading="lazy" class="alignnone wp-image-9339 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_loads_EC.png" alt="" width="674" height="311" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_loads_EC.png 1222w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_loads_EC-300x138.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_loads_EC-768x354.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_loads_EC-1024x472.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_loads_EC-50x23.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_loads_EC-60x28.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_loads_EC-35x16.png 35w" sizes="(max-width: 674px) 100vw, 674px" /></div></div> <div class="su-column su-column-size-2-5"><div class="su-column-inner su-u-clearfix su-u-trim"><img decoding="async" loading="lazy" class="alignnone size-full wp-image-9422" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_etabs_loads_USA.png" alt="" width="675" height="563" /></div></div></div></p>
<p>Depending on the design code, you must map each combination with either</p>
<ul>
<li>Eurocode Limit States
<ul>
<li>ULS &#8211; Ultimate Limit State Combinations: Fundamental (FC), Seismic (SC), Fire (FI) or Accidental (AC)</li>
<li>SLS &#8211; Serviceability Limit State Combinations: Rare (RC), Frequent (FC) or Quasi-Permanent (QP)</li>
<li>Custom</li>
</ul>
</li>
<li>Armerican
<ul>
<li>Strength</li>
<li>Service</li>
<li>Custom</li>
</ul>
</li>
</ul>
<p>On hoovering with the mouse over the combination&#8217;s name, you can see the build up of the combination (e.g. 1.35 DL + 1.50 LL).</p>
<p>Use SHIFT and CTRL commands as in Windows to select one or multiple items. For example, to select all, use &#8216;CTRL+A&#8217; and then, select the &#8220;+&#8221; button in the corresponding column.</p>
<p>Envelope combinations and dynamic seismic combinations are cannot be matched, as this is not supported by BIM Expert. These types of combinations are considered non-valid and will be greyed out. Static seismic combinations can be mapped.</p>
<p>Remark: If you cancel that load mapping dialog, combinations are neglected and the conversion proceeds.</p>
<h4>2.1.5 Reporting</h4>
<p>In case of severe incidences, you get a report of the incidences. It usually concerns load cases or element behavior that are not supported by BIM Expert. Click &#8216;Continue&#8217; to proceed anyway.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9349 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_reportincidences.png" alt="" width="573" height="412" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_reportincidences.png 963w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_reportincidences-300x216.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_reportincidences-768x552.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_reportincidences-50x36.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_reportincidences-60x43.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromcsi_sap_reportincidences-35x25.png 35w" sizes="(max-width: 573px) 100vw, 573px" /></p>
<p>The model is now in BIM Expert.</p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<h3>2.2 From BIM Expert to PowerConnect</h3>
<p><p>In the Model tab, select ‘Export’. Next, choose the destination software, namely PowerConnect. Click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" sizes="(max-width: 29px) 100vw, 29px" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" alt="" width="29" height="28" /> to continue.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9530 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png" alt="" width="397" height="241" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png 602w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-300x182.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-50x30.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-60x36.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-35x21.png 35w" sizes="(max-width: 397px) 100vw, 397px" /></p>
<h4 id="2-2-1-settings">2.2.1 Settings</h4>
<p>You can choose to either</p>
<ul>
<li>save the model as *.bpc-file</li>
<li>send the model to the current open PowerConnect instance &#8211; you see all open instances of PowerConnect</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9533 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png" alt="" width="564" height="152" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png 735w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-300x81.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-50x13.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-60x16.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-35x9.png 35w" sizes="(max-width: 564px) 100vw, 564px" /></p>
<p>Select your choice and click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" alt="" width="29" height="28" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" sizes="(max-width: 29px) 100vw, 29px" /> to continue.</p>
<h5>2.2.2 Automatic detection of connection components</h5>
<p>BIM Expert automatically detects existing connection components in the model. You get an overview of all found connection components and whether they can be transferred to PowerConnect.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9569 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png" alt="" width="790" height="349" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png 1654w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-300x132.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-768x339.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-1024x452.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-50x22.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-60x26.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-35x15.png 35w" sizes="(max-width: 790px) 100vw, 790px" /></p>
<p>&nbsp;</p>
<p>Use the eye button in the &#8216;Show&#8217; column to see a detailed popup window of the connection.</p>
<p>Possible descriptions are</p>
<ul>
<li><em>Some internal forces could not be retrieved from the analysis results</em><br />
No (or not all) internal forces are present from the source software.</li>
<li><em>The connection is identical to connection(s) {IDs} and therefore has been grouped</em><br />
Identical connections will be treated as one connection. You must only calculate the connections one, with envelope forces.</li>
<li><em>Connection merged with one or more parts of the following connection: {ID}</em><br />
The connection is merged with other one to create a more complex connection (e.g. two shear connections to beam-column are merged to design a double-sided shear connection)</li>
<li><em>Connection divided into &lt;&#8230;.&gt; connections </em><br />
A complex connection has been split up into smaller PowerConnect connections</li>
<li><em>The connection bars/plates with following ID&#8217;s could not be recognized: {IDs} </em><br />
The connection is recognized and can be calculated with PowerConnect, execpt for these bars/plates, with given Ids</li>
<li><em>Connection type not support</em><br />
This connection configuration cannot be calculated by PowerConnect, so it will not be transferred.</li>
</ul>
<p>If no connections are found, you will see</p>
<p><img decoding="async" loading="lazy" class="wp-image-9573 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png" alt="" width="381" height="223" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png 538w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-300x176.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-50x29.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-60x35.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-35x20.png 35w" sizes="(max-width: 381px) 100vw, 381px" /></p>
<h4>2.2.3 Add connections manually via Connection Assembler</h4>
<p>You can make your own connections by clicking ‘Modify’ (see image above).</p>
<p>In the next window, you see on the left hand side the BIM Expert model. In this window you see the regular scroll, 3D orbit and pan functions. On the right hand side, there is on top an overview of created connections and at the bottom, the &#8216;Create&#8217; button to make new connections.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9546 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png" alt="" width="712" height="356" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png 1553w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-300x150.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-768x384.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-1024x512.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-50x25.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-60x30.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-35x18.png 35w" sizes="(max-width: 712px) 100vw, 712px" /></p>
<p>In the next step you choose the connection type</p>
<ul>
<li>Moment connections: beam-column, beam-beam, splice, beam-column-beam or CHS splice</li>
<li>Shear connections: beam-column or beam-beam, beam-column-beam or beam-beam-beam</li>
<li>Base plate connections</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9537 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler2.png" alt="" width="777" height="192" /></p>
<p>After selecting for example ‘Beam to column’ you select the column and next the beam element from the 3D image on the left hand side. Click once on the column element and next on the beam element. BIM Expert will list and indicate which connections are possible:</p>
<ul>
<li>Beam to column flange &gt; possible, and marked with <img decoding="async" loading="lazy" class="alignnone size-full wp-image-9559" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_check.png" alt="" width="20" height="20" /></li>
<li>Beam to column web &gt; not possible, and not marked – you can click the orange arrow <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9558 size-full" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_arrow.png" alt="" width="21" height="20" />at the end to fold out the details and see why this connection is not possible.</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9542 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png" alt="" width="350" height="348" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png 587w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-150x150.png 150w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-300x298.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-50x50.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-60x60.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-35x35.png 35w" sizes="(max-width: 350px) 100vw, 350px" /></p>
<p>On clicking ‘Create’, the connection is added to the list of connections on top. Having selected the beam-column type, you can now continue making this type of connections, until you click ‘Change pattern’.</p>
<p><img decoding="async" loading="lazy" class=" wp-image-9543 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png" alt="" width="391" height="354" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png 583w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-300x271.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-50x45.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-60x54.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-35x32.png 35w" sizes="(max-width: 391px) 100vw, 391px" /></p>
<p>When the connection definition is finished, you click ‘Close’ and ‘Accept’ to continue to PowerConnect.</p>
<p>If you have chosen to open the model directly in PowerConnect, you will get a notification in PowerConnect on the right side. You can now choose to load the model or to delete it (by using the ‘x’).</p>
<p><img decoding="async" loading="lazy" class="wp-image-9553 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png" alt="" width="403" height="160" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png 549w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-300x119.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-50x20.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-60x24.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-35x14.png 35w" sizes="(max-width: 403px) 100vw, 403px" /></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<h2 id="1-preparation-in-revit"><strong>3. Final steps in PowerConnect</strong></h2>
<p><p>All connections will appear in the node list on the left side (as from PowerConnect 2021).  Remember that all identical connections will be grouped as 1.</p>
<p>Connections made with the Connection Assembler might appear with a red bar and as &#8216;Undefined&#8217;.  The connector type must be chosen (e.g. end plate, shear plate, welded, angles etc)</p>
<p><img decoding="async" loading="lazy" class="wp-image-9555 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png" alt="" width="817" height="282" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png 1731w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-300x103.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-768x265.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-1024x353.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-50x17.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-60x21.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-35x12.png 35w" sizes="(max-width: 817px) 100vw, 817px" /></p>
<p>Click on this connection to set the connector.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9554 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png" alt="" width="765" height="284" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png 1729w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-300x111.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-768x285.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-1024x380.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-50x19.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-60x22.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-35x13.png 35w" sizes="(max-width: 765px) 100vw, 765px" /></p>
<p>If no loads or internal forces were transferred, you should add loads in PowerConnect, in order to have a proper design of the connections.<script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<p><div>
<h2 id="1-preparation-in-revit" class="wp-block-heading"><strong>4. Get started with BIM Expert<br />
</strong></h2>
</div>
<div style="text-align: left;"><div class="su-button-center"><a href="https://support.buildsoft.eu" class="su-button su-button-style-flat" style="color:#FFFFFF;background-color:#E74C3C;border-color:#b93d30;border-radius:0px" target="_blank" rel="noopener noreferrer"><span style="color:#FFFFFF;padding:8px 26px;font-size:20px;line-height:30px;border-color:#ef8277;border-radius:0px;text-shadow:none"><i class="sui sui-arrow-right" style="font-size:20px;color:#FFFFFF"></i> Download your free trial of BIM Expert</span></a></div></div>
<div><div class="su-spacer" style="height:75px"></div></div>
</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>From Tekla Structures to PowerConnect</title>
		<link>https://support.buildsoft.eu/knowledge-base/from-tekla-structures-to-powerconnect/</link>
		
		<dc:creator><![CDATA[Dorothee]]></dc:creator>
		<pubDate>Mon, 22 May 2023 10:14:39 +0000</pubDate>
				<guid isPermaLink="false">https://support.buildsoft.eu/?post_type=ht_kb&#038;p=9561</guid>

					<description><![CDATA[This article explains how to send a Tekla Structures model to PowerConnect, using BIM Expert. There are 2 ways to send your connections from Tekla Structures to PowerConnect:]]></description>
										<content:encoded><![CDATA[</p>
<p>This article explains how to send a Tekla Structures model to PowerConnect, using BIM Expert.</p>
</p>
<p><span id="more-9561"></span></p>
</p>
<figure class="wp-block-embed aligncenter is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio">
<div class="wp-block-embed__wrapper">
<iframe loading="lazy" title="How to send component 40 connections from Tekla to PowerConnect" width="1200" height="675" src="https://www.youtube.com/embed/lcg_fVqQF3g?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe>
</div><figcaption class="wp-element-caption">Connection component transfer to PowerConnect</figcaption></figure>
</p>
<p>There are 2 ways to send your connections from Tekla Structures to PowerConnect:</p>
</p>
<ul>
<li><strong>Connections components only (easiest, see video above):</strong>
<ul>
<li>connection components must be present in the model &#8211; only they will be transferred</li>
</p>
<li>requires no analytical model creation</li>
</p>
<li>additional connections via Connection Assembler are not possible</li>
</ul>
</li>
</p>
<li><strong>Analysis model</strong>:
<ul>
<li>connection components can be present in the model and will be recognized</li>
</p>
<li>requires the creation of an analytical model</li>
</p>
<li>extra connection can be added via the Connection Assembler</li>
</ul>
</li>
</ul>
<p><div class="su-tabs su-tabs-style-default su-tabs-mobile-stack" data-active="1" data-scroll-offset="0" data-anchor-in-url="no"><div class="su-tabs-nav"><span class="" data-anchor="connectioncomponent" data-url="" data-target="" tabindex="0" role="button">Connection components</span><span class="" data-anchor="analysismodel" data-url="" data-target="" tabindex="0" role="button">Analysis model</span></div><div class="su-tabs-panes"><div class="su-tabs-pane su-u-clearfix su-u-trim" data-title="Connection components">
</p>
</p>
<h2 class="wp-block-heading"><strong>1. Preparation in Tekla Structures</strong></h2>
</p>
<p>The transfer is based on the connection components.&nbsp; Make sure you have some in your model. The components below are supported by PowerConnect.</p>
</p>
<figure class="wp-block-image aligncenter size-full is-resized"><a href="https://support.buildsoft.eu/wp-content/uploads/2024/04/bimexpert_importfromtekla_supportedcomponents.png"><img decoding="async" loading="lazy" src="https://support.buildsoft.eu/wp-content/uploads/2024/04/bimexpert_importfromtekla_supportedcomponents.png" alt="" class="wp-image-12704" width="423" height="270"/></a><figcaption class="wp-element-caption">By PowerConnect supported Tekla Structures connection components</figcaption></figure>
</p>
<h2 class="wp-block-heading"><strong>2. Send model from Tekla Structures to PowerConnect</strong></h2>
</p>
<h3 class="wp-block-heading">2.1 From Tekla Structures to BIM Expert</h3>
</p>
<p><p>    		<div class="hts-messages hts-messages--info  hts-messages--withtitle hts-messages--withicon " id="" style="">
    			<span class="hts-messages__title">Tip</span>    			    				<p>
    					In the BIM Expert menu &#8216;File &gt; Settings &gt; Tekla Structures&#8217;, opt for &#8216;Apply default actions in conversion&#8217;s dialogs&#8217;.</p>
<p>This option will reduce the number of conversion dialogs whenever possible. You only be prompted with dialogs when user input is required.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9489 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_defaultactions.png" alt="" width="301" height="98" /></p>
<p>    				</p>
    			    			
    		</div><!-- /.ht-shortcodes-messages -->
    		</p>
<p>There is more than 1 way to send connections from Tekla Structures to BIM Expert. You can either start from</p>
<p><div class="su-row"></p>
<p><div class="su-column su-column-size-1-2"><div class="su-column-inner su-u-clearfix su-u-trim"><em>BuildSoft menu in the top ribbon</em><img decoding="async" loading="lazy" class="alignnone wp-image-9493" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_buildsoftmenu.png" alt="" width="275" height="105" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_buildsoftmenu.png 340w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_buildsoftmenu-300x115.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_buildsoftmenu-50x19.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_buildsoftmenu-60x23.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_buildsoftmenu-35x13.png 35w" sizes="(max-width: 275px) 100vw, 275px" /></div></div></p>
<p><div class="su-column su-column-size-1-2"><div class="su-column-inner su-u-clearfix su-u-trim"><em>Applications and components sidebar</em><br />
<img decoding="async" loading="lazy" class="alignnone wp-image-9492" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_applicationscomp.png" alt="" width="314" height="214" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_applicationscomp.png 562w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_applicationscomp-300x204.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_applicationscomp-50x34.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_applicationscomp-60x41.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_applicationscomp-35x24.png 35w" sizes="(max-width: 314px) 100vw, 314px" /></div></div></div></p>
<p>Click the <strong>BIM Expert icon or PowerConnect icon</strong> to launch the transfer. Next you need to select what items to include:</p>
<p><div class="su-row"><div class="su-column su-column-size-1-2"><div class="su-column-inner su-u-clearfix su-u-trim"><br />
<img decoding="async" loading="lazy" class="wp-image-12713 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2024/04/bimexpert_importfromtekla_beconnections.png" alt="" width="318" height="276" /></p>
<p></div></div><div class="su-column su-column-size-1-2"><div class="su-column-inner su-u-clearfix su-u-trim"></p>
<p><img decoding="async" loading="lazy" class="wp-image-12714 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2024/04/bimexpert_importfromtekla_exportpcconnections.png" alt="" width="368" height="206" data-wp-editing="1" /><br />
</div></div></div></p>
<ul>
<li>Additional data: data that came from a previous transfer, but is not supported by Tekla Structures. This information is kept and can now be taken along in the current transfer (e.g. seismic information, soil layers, &#8230;)</li>
<li>Internal forces from &#8216;End Conditions&#8217;.  The End Conditions tab can be found in the element&#8217;s UDA (User Defined Attributes)</li>
</ul>
<p>Click Ok to proceed.  In the left bottom of the Tekla Structures you will see the information on what to do next:</p>
<p><img decoding="async" loading="lazy" class=" wp-image-12716 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2024/04/bimexpert_importfromtekla_selectconnections.png" alt="" width="331" height="90" /></p>
<h4>2.1.1 Selection of elements</h4>
<p>Select the elements and <strong>confirm your selection by clicking the middle mouse button</strong> (mouse wheel).</p>
<p>You will get an overview of all selected connection components:</p>
<p><img decoding="async" loading="lazy" class="wp-image-12717 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2024/04/bimexpert_importfromtekla_exportpcconnectionlist.png" alt="" width="457" height="332" /></p>
<p>&nbsp;</p>
<h4 id="2-2-4-connections-and-components">2.1.2 Component bundles</h4>
<p>If you have turned off the option to reduce the dialog windows, you will get an overview of all connections components in the model and the possibility to bundle components.</p>
<p><div class="su-spoiler su-spoiler-style-default su-spoiler-icon-plus su-spoiler-closed" data-scroll-offset="0" data-anchor-in-url="no"><div class="su-spoiler-title" tabindex="0" role="button"><span class="su-spoiler-icon"></span>Component selection and group dialog</div><div class="su-spoiler-content su-u-clearfix su-u-trim"></p>
<p><img decoding="async" loading="lazy" class="wp-image-9479 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview.png" alt="" width="792" height="271" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview.png 1231w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview-300x103.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview-768x263.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview-1024x351.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview-50x17.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview-60x21.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview-35x12.png 35w" sizes="(max-width: 792px) 100vw, 792px" /></p>
<p>In this window you can do 2 things:</p>
<ul>
<li>Select the connections to be included in transfer, via the checkbox in the &#8216;Accept&#8217; column</li>
<li>Bundle connection components into larger complex connection groups:
<ol>
<li>Position this window in a corner of your screen, because once you start adding groups, the window position is locked.</li>
<li>Click &#8216;Add group&#8217; to select the components.</li>
<li>Select the components by clicking the component arrow. All components should logically be around a single node of course.</li>
<li>Confirm the selection with the middle mouse button.</li>
<li>The group is now listed with the reference ids of the individual components.</li>
</ol>
</li>
</ul>
<p>If there are materials of bolt elements to be mapped, they will appear in the next pop-up window.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9482 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_materialmapping.png" alt="" width="594" height="196" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_materialmapping.png 776w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_materialmapping-300x99.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_materialmapping-768x253.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_materialmapping-50x16.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_materialmapping-60x20.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_materialmapping-35x12.png 35w" sizes="(max-width: 594px) 100vw, 594px" /></p>
<p><img decoding="async" loading="lazy" class="wp-image-9481 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_boltmapping.png" alt="" width="465" height="297" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_boltmapping.png 785w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_boltmapping-300x191.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_boltmapping-768x490.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_boltmapping-50x32.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_boltmapping-60x38.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_boltmapping-35x22.png 35w" sizes="(max-width: 465px) 100vw, 465px" /></p>
<p></div></div></p>
<p>The model is now in BIM Expert.</p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
</p>
<h3 class="wp-block-heading">2.2 From BIM Expert to PowerConnect</h3>
</p>
<p><p>
<p>In the Model tab, select ‘Export’. Next, choose the destination software, namely PowerConnect. Click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" sizes="(max-width: 29px) 100vw, 29px" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" alt="" width="29" height="28" /> to continue.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9530 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png" alt="" width="397" height="241" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png 602w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-300x182.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-50x30.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-60x36.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-35x21.png 35w" sizes="(max-width: 397px) 100vw, 397px" /></p>
<h4 id="2-2-1-settings">2.2.1 Settings</h4>
<p>You can choose to either</p>
<ul>
<li>save the model as *.bpc-file</li>
<li>send the model to the current open PowerConnect instance &#8211; you see all open instances of PowerConnect</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9533 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png" alt="" width="564" height="152" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png 735w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-300x81.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-50x13.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-60x16.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-35x9.png 35w" sizes="(max-width: 564px) 100vw, 564px" /></p>
<p>Select your choice and click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" alt="" width="29" height="28" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" sizes="(max-width: 29px) 100vw, 29px" /> to continue.</p>
<h5>2.2.2 Automatic detection of connection components</h5>
<p>BIM Expert automatically detects existing connection components in the model. You get an overview of all found connection components and whether they can be transferred to PowerConnect.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9569 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png" alt="" width="790" height="349" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png 1654w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-300x132.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-768x339.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-1024x452.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-50x22.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-60x26.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-35x15.png 35w" sizes="(max-width: 790px) 100vw, 790px" /></p>
<p>Use the eye button in the &#8216;Show&#8217; column to see a detailed popup window of the connection.</p>
<p>Possible descriptions are</p>
<ul>
<li><em>Some internal forces could not be retrieved from the analysis results</em><br />
No (or not all) internal forces are present from the source software.</li>
<li><em>The connection is identical to connection(s) {IDs} and therefore has been grouped</em><br />
Identical connections will be treated as one connection. You must only calculate the connections one, with envelope forces.</li>
<li><em>Connection merged with one or more parts of the following connection: {ID}</em><br />
The connection is merged with other one to create a more complex connection (e.g. two shear connections to beam-column are merged to design a double-sided shear connection)</li>
<li><em>Connection divided into &lt;&#8230;.&gt; connections </em><br />
A complex connection has been split up into smaller PowerConnect connections</li>
<li><em>The connection bars/plates with following ID&#8217;s could not be recognized: {IDs} </em><br />
The connection is recognized and can be calculated with PowerConnect, execpt for these bars/plates, with given Ids</li>
<li><em>Connection type not support</em><br />
This connection configuration cannot be calculated by PowerConnect, so it will not be transferred.</li>
</ul>
<p>Click ‘Accept’ to continue to PowerConnect.</p>
<p>If you have chosen to open the model directly in PowerConnect, you will get a notification in PowerConnect on the right side. You can now choose to load the model or to delete it (by using the ‘x’).</p>
<p><img decoding="async" loading="lazy" class="wp-image-9553 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png" alt="" width="403" height="160" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png 549w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-300x119.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-50x20.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-60x24.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-35x14.png 35w" sizes="(max-width: 403px) 100vw, 403px" /></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>

</p>
</p>
<p></div>
<div class="su-tabs-pane su-u-clearfix su-u-trim" data-title="Analysis model"></p>
<h2><strong>1. Preparation in Tekla Structures<br /></strong></h2>
<p>The transfer is based on the analytical model. So in Tekla Structures, you need to create an analytical model first. The quality and coherence (connection between elements) of the analytical model is not relevant, as PowerConnect uses the physical model.</p>
<p><div class="su-spoiler su-spoiler-style-default su-spoiler-icon-plus su-spoiler-closed" data-scroll-offset="0" data-anchor-in-url="no"><div class="su-spoiler-title" tabindex="0" role="button"><span class="su-spoiler-icon"></span>Creating the analytical model fast (no quality demand)</div><div class="su-spoiler-content su-u-clearfix su-u-trim"></p>
<p>In the top ribbon, go to the tab &#8216;Analysis &amp; Design&#8217; and click the &#8216;A &amp; D models&#8217; command</p>
<p><img decoding="async" loading="lazy" class=" wp-image-9583 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exportfromtekla_adribbon.png" alt="" width="414" height="107" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exportfromtekla_adribbon.png 499w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exportfromtekla_adribbon-300x78.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exportfromtekla_adribbon-50x13.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exportfromtekla_adribbon-60x16.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exportfromtekla_adribbon-35x9.png 35w" sizes="(max-width: 414px) 100vw, 414px" /></p>
<p>Next create a New analysis model &#8211; a Analysis Model Properties window will pop-up. The analysis model content should be &#8216;Full model&#8217; &#8211; unless you want to start selecting element per element.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9584 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exportfromtekla_createanalyticalmodel.png" alt="" width="524" height="364" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exportfromtekla_createanalyticalmodel.png 1055w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exportfromtekla_createanalyticalmodel-300x208.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exportfromtekla_createanalyticalmodel-768x533.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exportfromtekla_createanalyticalmodel-1024x710.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exportfromtekla_createanalyticalmodel-50x35.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exportfromtekla_createanalyticalmodel-60x42.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exportfromtekla_createanalyticalmodel-35x24.png 35w" sizes="(max-width: 524px) 100vw, 524px" /></p>
<p></div></div></p>
<h2 id="1-preparation-in-revit"><strong>2. Send model from Tekla Structures to PowerConnect</strong></h2>
<h3>2.1 From Tekla Structures to BIM Expert</h3>
<p><p>    		<div class="hts-messages hts-messages--info  hts-messages--withtitle hts-messages--withicon " id="" style="">
    			<span class="hts-messages__title">Tip</span>    			    				<p>
    					In the BIM Expert menu &#8216;File &gt; Settings &gt; Tekla Structures&#8217;, opt for &#8216;Apply default actions in conversion&#8217;s dialogs&#8217;.</p>
<p>This option will reduce the number of conversion dialogs whenever possible. You only be prompted with dialogs when user input is required.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9489 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_defaultactions.png" alt="" width="301" height="98" /></p>
<p>    				</p>
    			    			
    		</div><!-- /.ht-shortcodes-messages -->
    		</p>
<p>There is more than 1 way to send models from Tekla Structures to BIM Expert. You can either start from</p>
<p><div class="su-row"><br />
<div class="su-column su-column-size-1-2"><div class="su-column-inner su-u-clearfix su-u-trim"><em>BuildSoft menu in the top ribbon</em><img decoding="async" loading="lazy" class="alignnone wp-image-9493" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_buildsoftmenu.png" alt="" width="275" height="105" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_buildsoftmenu.png 340w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_buildsoftmenu-300x115.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_buildsoftmenu-50x19.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_buildsoftmenu-60x23.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_buildsoftmenu-35x13.png 35w" sizes="(max-width: 275px) 100vw, 275px" /></div></div><br />
<div class="su-column su-column-size-1-2"><div class="su-column-inner su-u-clearfix su-u-trim"><em>Applications and components sidebar</em><br />
<img decoding="async" loading="lazy" class="alignnone wp-image-9492" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_applicationscomp.png" alt="" width="314" height="214" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_applicationscomp.png 562w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_applicationscomp-300x204.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_applicationscomp-50x34.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_applicationscomp-60x41.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_applicationscomp-35x24.png 35w" sizes="(max-width: 314px) 100vw, 314px" /></div></div></div></p>
<p>Click the BIM Expert icon to launch the transfer. Next you need to select what items to include, in addition to the Analysis model:</p>
<p><img decoding="async" loading="lazy" class="wp-image-9491 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla.png" alt="" width="348" height="303" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla.png 464w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla-300x261.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla-50x44.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla-60x52.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla-35x30.png 35w" sizes="(max-width: 348px) 100vw, 348px" /></p>
<ul>
<li>Additional data: data that came from a previous transfer, but is not supported by Tekla Structures. This information is kept and can now be taken along in the current transfer (e.g. seismic information, soil layers, &#8230;)</li>
<li>Rigid links</li>
<li>Connection: full or only haunches</li>
<li>Internal forces from &#8216;End Conditions&#8217;.  The End Conditions tab can be found in the element&#8217;s UDA (User Defined Attributes):</li>
</ul>
<p><div class="su-spoiler su-spoiler-style-default su-spoiler-icon-plus su-spoiler-closed" data-scroll-offset="0" data-anchor-in-url="no"><div class="su-spoiler-title" tabindex="0" role="button"><span class="su-spoiler-icon"></span>Alternative method: start in BIM Expert</div><div class="su-spoiler-content su-u-clearfix su-u-trim"></p>
<p>Alternatively, you can start in BIM Expert: click ‘Model &gt; Import’ and select the Tekla Structures plugin. Choose the Tekla Structures version and what elements to import (see above).</p>
<p><div class="su-row"><br />
<div class="su-column su-column-size-1-2"><div class="su-column-inner su-u-clearfix su-u-trim"><img decoding="async" loading="lazy" class="alignnone wp-image-9500" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_be.png" alt="" width="243" height="237" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_be.png 375w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_be-300x292.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_be-50x50.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_be-60x58.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_be-35x35.png 35w" sizes="(max-width: 243px) 100vw, 243px" /></div></div><br />
<div class="su-column su-column-size-1-2"><div class="su-column-inner su-u-clearfix su-u-trim"><img decoding="async" loading="lazy" class="alignnone wp-image-9501" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_be_options.png" alt="" width="303" height="377" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_be_options.png 387w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_be_options-241x300.png 241w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_be_options-40x50.png 40w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_be_options-48x60.png 48w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_be_options-28x35.png 28w" sizes="(max-width: 303px) 100vw, 303px" /><br />
</div></div></div><br />
</div></div></p>
<p>No matter the way you have chosen, BIM Expert will now take over.</p>
<h4>2.1.1 Settings</h4>
<p>If you have more than one analytical model in Tekla Structures, you need to select the analysis model that you want to transfer</p>
<p><img decoding="async" loading="lazy" class=" wp-image-9477 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_analysismodelchoice.png" alt="" width="633" height="167" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_analysismodelchoice.png 796w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_analysismodelchoice-300x79.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_analysismodelchoice-768x203.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_analysismodelchoice-50x13.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_analysismodelchoice-60x16.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_analysismodelchoice-35x9.png 35w" sizes="(max-width: 633px) 100vw, 633px" /></p>
<p>Next, the Tekla Structures sections and materials must be mapped with BIM Expert&#8217;s section and material database. BIM Expert will try to find as many automatic mapping matches as possible. In case all sections and materials find a match, you will not see any dialogs for mapping.</p>
<h4>2.1.2 Material mapping</h4>
<p>In case you have turned off the option to reduce dialog windows, you might see a material mapping dialog for mapping unknown materials. In the &#8216;reduce dialog window&#8217; case, unknown materials will be added as new.</p>
<p><div class="su-spoiler su-spoiler-style-default su-spoiler-icon-plus su-spoiler-closed" data-scroll-offset="0" data-anchor-in-url="no"><div class="su-spoiler-title" tabindex="0" role="button"><span class="su-spoiler-icon"></span>Material mapping dialog</div><div class="su-spoiler-content su-u-clearfix su-u-trim"></p>
<p>Database materials such as steel (e.g. S235, ASTM-Grades), concrete (e.g. C25/30, M50) and timber (e.g. C24, D50, GL28c) are mapped automatically. In some cases, the match is not automatically found, because the name differs (<em>Concrete grade C25</em> instead of <em>Concrete grade C25/30</em>). In that case, you can select the correct material from the database.</p>
<p><em>Tip: When searching an item in the database, type the first letters of the name to find it more quickly.</em></p>
<p><img decoding="async" loading="lazy" class="wp-image-9512 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_materialmapping.png" alt="" width="593" height="197" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_materialmapping.png 776w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_materialmapping-300x100.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_materialmapping-768x255.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_materialmapping-50x17.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_materialmapping-60x20.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_materialmapping-35x12.png 35w" sizes="(max-width: 593px) 100vw, 593px" /></p>
<p>If you cannot find a suited counterpart in the BIM Expert database, the material can be added as new.</p>
<p></div></div></p>
<h4>2.1.3 Section mapping</h4>
<p>In case you have turned off the option to reduce dialog windows, you might see a section mapping dialog for mapping unknown sections. In the &#8216;reduce dialog window&#8217; case, unknown sections will be added as new.</p>
<p><div class="su-spoiler su-spoiler-style-default su-spoiler-icon-plus su-spoiler-closed" data-scroll-offset="0" data-anchor-in-url="no"><div class="su-spoiler-title" tabindex="0" role="button"><span class="su-spoiler-icon"></span>Section mapping dialog</div><div class="su-spoiler-content su-u-clearfix su-u-trim"></p>
<p>Database sections (such as I, H, UB, UC, W, C, U, O, ☐ and L sections) are mapped automatically. In some cases, the match is not automatically found, because the name differs  (e.g. name is <em>HEB300 &#8211; S235</em> instead of <em>HEB300</em>). In that case, you can select the correct cross-section from the database.<br />
<em>Tip: When searching an item in the database, type the first letters of the name to find it more quickly.</em></p>
<p>Parametric sections (e.g. rectangles, circle, trapezium, &#8230;) and user defined sections are not in the database. They should always be added as new.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9513 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_sectionmapping.png" alt="" width="655" height="238" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_sectionmapping.png 1095w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_sectionmapping-300x109.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_sectionmapping-768x279.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_sectionmapping-1024x372.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_sectionmapping-50x18.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_sectionmapping-60x22.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_sectionmapping-35x13.png 35w" sizes="(max-width: 655px) 100vw, 655px" /></p>
<p></div></div></p>
<h4 id="2-2-4-connections-and-components">2.1.4 Connections and component bundles</h4>
<p>In case you have chosen to export connections and there are connections in the model, BIM Expert will now start the connection conversion.</p>
<p>If you have turned off the option to reduce the dialog windows, you will get an overview of all connections components in the model and the possibility to bundle components.</p>
<p><div class="su-spoiler su-spoiler-style-default su-spoiler-icon-plus su-spoiler-closed" data-scroll-offset="0" data-anchor-in-url="no"><div class="su-spoiler-title" tabindex="0" role="button"><span class="su-spoiler-icon"></span>Component selection and group dialog</div><div class="su-spoiler-content su-u-clearfix su-u-trim"></p>
<p><img decoding="async" loading="lazy" class="wp-image-9479 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview.png" alt="" width="792" height="271" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview.png 1231w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview-300x103.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview-768x263.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview-1024x351.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview-50x17.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview-60x21.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connectionoverview-35x12.png 35w" sizes="(max-width: 792px) 100vw, 792px" /></p>
<p>In this window you can do 2 things:</p>
<ul>
<li>Select the connections to be included in transfer, via the checkbox in the &#8216;Accept&#8217; column</li>
<li>Bundle connection components into larger complex connection groups:
<ol>
<li>Position this window in a corner of your screen, because once you start adding groups, the window position is locked.</li>
<li>Click &#8216;Add group&#8217; to select the components.</li>
<li>Select the components by clicking the component arrow. All components should logically be around a single node of course.</li>
<li>Confirm the selection with the middle mouse button.</li>
<li>The group is now listed with the reference ids of the individual components.</li>
</ol>
</li>
</ul>
<p>If there are materials of bolt elements to be mapped, they will appear in the next pop-up window.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9482 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_materialmapping.png" alt="" width="594" height="196" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_materialmapping.png 776w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_materialmapping-300x99.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_materialmapping-768x253.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_materialmapping-50x16.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_materialmapping-60x20.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_materialmapping-35x12.png 35w" sizes="(max-width: 594px) 100vw, 594px" /></p>
<p><img decoding="async" loading="lazy" class="wp-image-9481 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_boltmapping.png" alt="" width="465" height="297" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_boltmapping.png 785w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_boltmapping-300x191.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_boltmapping-768x490.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_boltmapping-50x32.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_boltmapping-60x38.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_importfromtekla_connection_boltmapping-35x22.png 35w" sizes="(max-width: 465px) 100vw, 465px" /></p>
<p></div></div></p>
<p>The model is now in BIM Expert.</p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<h3>2.2 From BIM Expert to PowerConnect</h3>
<p><p>In the Model tab, select ‘Export’. Next, choose the destination software, namely PowerConnect. Click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" sizes="(max-width: 29px) 100vw, 29px" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" alt="" width="29" height="28" /> to continue.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9530 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png" alt="" width="397" height="241" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png 602w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-300x182.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-50x30.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-60x36.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-35x21.png 35w" sizes="(max-width: 397px) 100vw, 397px" /></p>
<h4 id="2-2-1-settings">2.2.1 Settings</h4>
<p>You can choose to either</p>
<ul>
<li>save the model as *.bpc-file</li>
<li>send the model to the current open PowerConnect instance &#8211; you see all open instances of PowerConnect</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9533 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png" alt="" width="564" height="152" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png 735w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-300x81.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-50x13.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-60x16.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-35x9.png 35w" sizes="(max-width: 564px) 100vw, 564px" /></p>
<p>Select your choice and click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" alt="" width="29" height="28" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" sizes="(max-width: 29px) 100vw, 29px" /> to continue.</p>
<h5>2.2.2 Automatic detection of connection components</h5>
<p>BIM Expert automatically detects existing connection components in the model. You get an overview of all found connection components and whether they can be transferred to PowerConnect.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9569 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png" alt="" width="790" height="349" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png 1654w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-300x132.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-768x339.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-1024x452.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-50x22.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-60x26.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-35x15.png 35w" sizes="(max-width: 790px) 100vw, 790px" /></p>
<p>&nbsp;</p>
<p>Use the eye button in the &#8216;Show&#8217; column to see a detailed popup window of the connection.</p>
<p>Possible descriptions are</p>
<ul>
<li><em>Some internal forces could not be retrieved from the analysis results</em><br />
No (or not all) internal forces are present from the source software.</li>
<li><em>The connection is identical to connection(s) {IDs} and therefore has been grouped</em><br />
Identical connections will be treated as one connection. You must only calculate the connections one, with envelope forces.</li>
<li><em>Connection merged with one or more parts of the following connection: {ID}</em><br />
The connection is merged with other one to create a more complex connection (e.g. two shear connections to beam-column are merged to design a double-sided shear connection)</li>
<li><em>Connection divided into &lt;&#8230;.&gt; connections </em><br />
A complex connection has been split up into smaller PowerConnect connections</li>
<li><em>The connection bars/plates with following ID&#8217;s could not be recognized: {IDs} </em><br />
The connection is recognized and can be calculated with PowerConnect, execpt for these bars/plates, with given Ids</li>
<li><em>Connection type not support</em><br />
This connection configuration cannot be calculated by PowerConnect, so it will not be transferred.</li>
</ul>
<p>If no connections are found, you will see</p>
<p><img decoding="async" loading="lazy" class="wp-image-9573 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png" alt="" width="381" height="223" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png 538w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-300x176.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-50x29.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-60x35.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-35x20.png 35w" sizes="(max-width: 381px) 100vw, 381px" /></p>
<h4>2.2.3 Add connections manually via Connection Assembler</h4>
<p>You can make your own connections by clicking ‘Modify’ (see image above).</p>
<p>In the next window, you see on the left hand side the BIM Expert model. In this window you see the regular scroll, 3D orbit and pan functions. On the right hand side, there is on top an overview of created connections and at the bottom, the &#8216;Create&#8217; button to make new connections.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9546 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png" alt="" width="712" height="356" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png 1553w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-300x150.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-768x384.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-1024x512.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-50x25.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-60x30.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-35x18.png 35w" sizes="(max-width: 712px) 100vw, 712px" /></p>
<p>In the next step you choose the connection type</p>
<ul>
<li>Moment connections: beam-column, beam-beam, splice, beam-column-beam or CHS splice</li>
<li>Shear connections: beam-column or beam-beam, beam-column-beam or beam-beam-beam</li>
<li>Base plate connections</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9537 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler2.png" alt="" width="777" height="192" /></p>
<p>After selecting for example ‘Beam to column’ you select the column and next the beam element from the 3D image on the left hand side. Click once on the column element and next on the beam element. BIM Expert will list and indicate which connections are possible:</p>
<ul>
<li>Beam to column flange &gt; possible, and marked with <img decoding="async" loading="lazy" class="alignnone size-full wp-image-9559" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_check.png" alt="" width="20" height="20" /></li>
<li>Beam to column web &gt; not possible, and not marked – you can click the orange arrow <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9558 size-full" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_arrow.png" alt="" width="21" height="20" />at the end to fold out the details and see why this connection is not possible.</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9542 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png" alt="" width="350" height="348" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png 587w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-150x150.png 150w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-300x298.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-50x50.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-60x60.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-35x35.png 35w" sizes="(max-width: 350px) 100vw, 350px" /></p>
<p>On clicking ‘Create’, the connection is added to the list of connections on top. Having selected the beam-column type, you can now continue making this type of connections, until you click ‘Change pattern’.</p>
<p><img decoding="async" loading="lazy" class=" wp-image-9543 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png" alt="" width="391" height="354" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png 583w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-300x271.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-50x45.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-60x54.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-35x32.png 35w" sizes="(max-width: 391px) 100vw, 391px" /></p>
<p>When the connection definition is finished, you click ‘Close’ and ‘Accept’ to continue to PowerConnect.</p>
<p>If you have chosen to open the model directly in PowerConnect, you will get a notification in PowerConnect on the right side. You can now choose to load the model or to delete it (by using the ‘x’).</p>
<p><img decoding="async" loading="lazy" class="wp-image-9553 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png" alt="" width="403" height="160" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png 549w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-300x119.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-50x20.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-60x24.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-35x14.png 35w" sizes="(max-width: 403px) 100vw, 403px" /></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
<br />
</div></div></div></p>
<h2 id="1-preparation-in-revit"><strong>3. Final steps in PowerConnect</strong></h2>
<p><p>All connections will appear in the node list on the left side (as from PowerConnect 2021).  Remember that all identical connections will be grouped as 1.</p>
<p>Connections made with the Connection Assembler might appear with a red bar and as &#8216;Undefined&#8217;.  The connector type must be chosen (e.g. end plate, shear plate, welded, angles etc)</p>
<p><img decoding="async" loading="lazy" class="wp-image-9555 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png" alt="" width="817" height="282" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png 1731w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-300x103.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-768x265.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-1024x353.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-50x17.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-60x21.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-35x12.png 35w" sizes="(max-width: 817px) 100vw, 817px" /></p>
<p>Click on this connection to set the connector.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9554 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png" alt="" width="765" height="284" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png 1729w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-300x111.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-768x285.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-1024x380.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-50x19.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-60x22.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-35x13.png 35w" sizes="(max-width: 765px) 100vw, 765px" /></p>
<p>If no loads or internal forces were transferred, you should add loads in PowerConnect, in order to have a proper design of the connections.<script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<p><div>
<h2 id="1-preparation-in-revit" class="wp-block-heading"><strong>4. Get started with BIM Expert<br />
</strong></h2>
</div>
<div style="text-align: left;"><div class="su-button-center"><a href="https://support.buildsoft.eu" class="su-button su-button-style-flat" style="color:#FFFFFF;background-color:#E74C3C;border-color:#b93d30;border-radius:0px" target="_blank" rel="noopener noreferrer"><span style="color:#FFFFFF;padding:8px 26px;font-size:20px;line-height:30px;border-color:#ef8277;border-radius:0px;text-shadow:none"><i class="sui sui-arrow-right" style="font-size:20px;color:#FFFFFF"></i> Download your free trial of BIM Expert</span></a></div></div>
<div><div class="su-spacer" style="height:75px"></div></div>
</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>From Diamonds to PowerConnect</title>
		<link>https://support.buildsoft.eu/knowledge-base/from-diamonds-to-powerconnect/</link>
		
		<dc:creator><![CDATA[Dorothee]]></dc:creator>
		<pubDate>Mon, 15 May 2023 11:35:51 +0000</pubDate>
				<guid isPermaLink="false">https://support.buildsoft.eu/?post_type=ht_kb&#038;p=9609</guid>

					<description><![CDATA[This article explains how to send one or more Diamonds nodes to PowerConnect, using BIM Expert. 1. Preparation in Diamonds Make sure the model is calculated and that elastic results are available. 2. Send the Diamonds model to PowerConnect 2.1 From Diamonds to BIM Expert 2.2 From BIM Expert to...]]></description>
										<content:encoded><![CDATA[<p>This article explains how to send one or more Diamonds nodes to PowerConnect, using BIM Expert.</p>
<p><span id="more-9609"></span></p>
<p>    		<div class="hts-messages hts-messages--alert  hts-messages--withtitle hts-messages--withicon " id="" style="">
    			<span class="hts-messages__title">Attention</span>    			    				<p>
    					Next to the BIM Expert workflow, there is a direct PowerConnect integration in Diamonds. We do recommend to use the direct integration as it allows you store the connections in special library, and get a final verification in Diamonds.    				</p>
    			    			
    		</div><!-- /.ht-shortcodes-messages -->
    		</p>
<h2 id="1-preparation-in-revit"><strong>1. Preparation in Diamonds</strong></h2>
<p>Make sure the model is calculated and that elastic results are available.</p>
<h2 id="2-send-the-revit-model-to-tekla-structures"><strong>2. Send the Diamonds model to PowerConnect<br /></strong></h2>
<h3 id="2-1-from-revit-to-bim-expert">2.1 From Diamonds to BIM Expert</h3>
<p><p>In the File menu tab, select ‘Export &gt; Export to BIM Expert’  or simply use F8.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9114 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/diamonds_file_export_be.png" sizes="(max-width: 376px) 100vw, 376px" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/diamonds_file_export_be.png 680w, https://support.buildsoft.eu/wp-content/uploads/2023/05/diamonds_file_export_be-300x162.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/diamonds_file_export_be-50x27.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/diamonds_file_export_be-60x32.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/diamonds_file_export_be-35x19.png 35w" alt="" width="376" height="203" /></p>
<p>The geometry model is sent to BIM Expert. All sections and materials are automatically converted and transferred, as well as the loads and results (if present). The model is now in BIM Expert.</p>
</p>
<h3>2.2 From BIM Expert to PowerConnect</h3>
<p><p>In the Model tab, select ‘Export’. Next, choose the destination software, namely PowerConnect. Click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" sizes="(max-width: 29px) 100vw, 29px" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" alt="" width="29" height="28" /> to continue.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9530 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png" alt="" width="397" height="241" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png 602w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-300x182.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-50x30.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-60x36.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-35x21.png 35w" sizes="(max-width: 397px) 100vw, 397px" /></p>
<h4 id="2-2-1-settings">2.2.1 Settings</h4>
<p>You can choose to either</p>
<ul>
<li>save the model as *.bpc-file</li>
<li>send the model to the current open PowerConnect instance &#8211; you see all open instances of PowerConnect</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9533 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png" alt="" width="564" height="152" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png 735w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-300x81.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-50x13.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-60x16.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-35x9.png 35w" sizes="(max-width: 564px) 100vw, 564px" /></p>
<p>Select your choice and click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" alt="" width="29" height="28" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" sizes="(max-width: 29px) 100vw, 29px" /> to continue.</p>
<h5>2.2.2 Automatic detection of connection components</h5>
<p>BIM Expert automatically detects existing connection components in the model. You get an overview of all found connection components and whether they can be transferred to PowerConnect.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9569 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png" alt="" width="790" height="349" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png 1654w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-300x132.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-768x339.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-1024x452.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-50x22.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-60x26.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-35x15.png 35w" sizes="(max-width: 790px) 100vw, 790px" /></p>
<p>&nbsp;</p>
<p>Use the eye button in the &#8216;Show&#8217; column to see a detailed popup window of the connection.</p>
<p>Possible descriptions are</p>
<ul>
<li><em>Some internal forces could not be retrieved from the analysis results</em><br />
No (or not all) internal forces are present from the source software.</li>
<li><em>The connection is identical to connection(s) {IDs} and therefore has been grouped</em><br />
Identical connections will be treated as one connection. You must only calculate the connections one, with envelope forces.</li>
<li><em>Connection merged with one or more parts of the following connection: {ID}</em><br />
The connection is merged with other one to create a more complex connection (e.g. two shear connections to beam-column are merged to design a double-sided shear connection)</li>
<li><em>Connection divided into &lt;&#8230;.&gt; connections </em><br />
A complex connection has been split up into smaller PowerConnect connections</li>
<li><em>The connection bars/plates with following ID&#8217;s could not be recognized: {IDs} </em><br />
The connection is recognized and can be calculated with PowerConnect, execpt for these bars/plates, with given Ids</li>
<li><em>Connection type not support</em><br />
This connection configuration cannot be calculated by PowerConnect, so it will not be transferred.</li>
</ul>
<p>If no connections are found, you will see</p>
<p><img decoding="async" loading="lazy" class="wp-image-9573 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png" alt="" width="381" height="223" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png 538w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-300x176.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-50x29.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-60x35.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-35x20.png 35w" sizes="(max-width: 381px) 100vw, 381px" /></p>
<h4>2.2.3 Add connections manually via Connection Assembler</h4>
<p>You can make your own connections by clicking ‘Modify’ (see image above).</p>
<p>In the next window, you see on the left hand side the BIM Expert model. In this window you see the regular scroll, 3D orbit and pan functions. On the right hand side, there is on top an overview of created connections and at the bottom, the &#8216;Create&#8217; button to make new connections.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9546 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png" alt="" width="712" height="356" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png 1553w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-300x150.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-768x384.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-1024x512.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-50x25.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-60x30.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-35x18.png 35w" sizes="(max-width: 712px) 100vw, 712px" /></p>
<p>In the next step you choose the connection type</p>
<ul>
<li>Moment connections: beam-column, beam-beam, splice, beam-column-beam or CHS splice</li>
<li>Shear connections: beam-column or beam-beam, beam-column-beam or beam-beam-beam</li>
<li>Base plate connections</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9537 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler2.png" alt="" width="777" height="192" /></p>
<p>After selecting for example ‘Beam to column’ you select the column and next the beam element from the 3D image on the left hand side. Click once on the column element and next on the beam element. BIM Expert will list and indicate which connections are possible:</p>
<ul>
<li>Beam to column flange &gt; possible, and marked with <img decoding="async" loading="lazy" class="alignnone size-full wp-image-9559" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_check.png" alt="" width="20" height="20" /></li>
<li>Beam to column web &gt; not possible, and not marked – you can click the orange arrow <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9558 size-full" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_arrow.png" alt="" width="21" height="20" />at the end to fold out the details and see why this connection is not possible.</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9542 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png" alt="" width="350" height="348" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png 587w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-150x150.png 150w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-300x298.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-50x50.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-60x60.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-35x35.png 35w" sizes="(max-width: 350px) 100vw, 350px" /></p>
<p>On clicking ‘Create’, the connection is added to the list of connections on top. Having selected the beam-column type, you can now continue making this type of connections, until you click ‘Change pattern’.</p>
<p><img decoding="async" loading="lazy" class=" wp-image-9543 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png" alt="" width="391" height="354" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png 583w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-300x271.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-50x45.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-60x54.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-35x32.png 35w" sizes="(max-width: 391px) 100vw, 391px" /></p>
<p>When the connection definition is finished, you click ‘Close’ and ‘Accept’ to continue to PowerConnect.</p>
<p>If you have chosen to open the model directly in PowerConnect, you will get a notification in PowerConnect on the right side. You can now choose to load the model or to delete it (by using the ‘x’).</p>
<p><img decoding="async" loading="lazy" class="wp-image-9553 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png" alt="" width="403" height="160" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png 549w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-300x119.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-50x20.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-60x24.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-35x14.png 35w" sizes="(max-width: 403px) 100vw, 403px" /></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<h2 id="1-preparation-in-revit"><strong>3. Final steps in PowerConnect</strong></h2>
<p><p>All connections will appear in the node list on the left side (as from PowerConnect 2021).  Remember that all identical connections will be grouped as 1.</p>
<p>Connections made with the Connection Assembler might appear with a red bar and as &#8216;Undefined&#8217;.  The connector type must be chosen (e.g. end plate, shear plate, welded, angles etc)</p>
<p><img decoding="async" loading="lazy" class="wp-image-9555 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png" alt="" width="817" height="282" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png 1731w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-300x103.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-768x265.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-1024x353.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-50x17.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-60x21.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-35x12.png 35w" sizes="(max-width: 817px) 100vw, 817px" /></p>
<p>Click on this connection to set the connector.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9554 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png" alt="" width="765" height="284" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png 1729w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-300x111.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-768x285.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-1024x380.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-50x19.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-60x22.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-35x13.png 35w" sizes="(max-width: 765px) 100vw, 765px" /></p>
<p>If no loads or internal forces were transferred, you should add loads in PowerConnect, in order to have a proper design of the connections.<script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<p><div>
<h2 id="1-preparation-in-revit" class="wp-block-heading"><strong>4. Get started with BIM Expert<br />
</strong></h2>
</div>
<div style="text-align: left;"><div class="su-button-center"><a href="https://support.buildsoft.eu" class="su-button su-button-style-flat" style="color:#FFFFFF;background-color:#E74C3C;border-color:#b93d30;border-radius:0px" target="_blank" rel="noopener noreferrer"><span style="color:#FFFFFF;padding:8px 26px;font-size:20px;line-height:30px;border-color:#ef8277;border-radius:0px;text-shadow:none"><i class="sui sui-arrow-right" style="font-size:20px;color:#FFFFFF"></i> Download your free trial of BIM Expert</span></a></div></div>
<div><div class="su-spacer" style="height:75px"></div></div>
</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>From UBSM to PowerConnect</title>
		<link>https://support.buildsoft.eu/knowledge-base/from-ubsm-to-powerconnect/</link>
		
		<dc:creator><![CDATA[Dorothee]]></dc:creator>
		<pubDate>Wed, 03 May 2023 11:46:43 +0000</pubDate>
				<guid isPermaLink="false">https://support.buildsoft.eu/?post_type=ht_kb&#038;p=9706</guid>

					<description><![CDATA[This article explains how to send one or more UBSM nodes to PowerConnect, using BIM Expert. 1. Preparation in UBSM 2. Send the UBSM model to PowerConnect 2.1 From UBSM to BIM Expert 2.2 From BIM Expert to PowerConnect 3. Final steps in PowerConnect]]></description>
										<content:encoded><![CDATA[<p>This article explains how to send one or more UBSM nodes to PowerConnect, using BIM Expert.<br /><span id="more-9706"></span></p>
<h2 id="1-preparation-in-revit"><strong>1. Preparation in UBSM</strong></h2>
<h2 id="2-send-the-revit-model-to-tekla-structures"><strong>2. Send the UBSM model to PowerConnect<br /></strong></h2>
<h3 id="2-1-from-revit-to-bim-expert">2.1 From UBSM to BIM Expert</h3>
<p><p>In the File menu tab, select ‘Export &gt; Export to BIM Expert’  or simply use F8.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9114 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/diamonds_file_export_be.png" sizes="(max-width: 376px) 100vw, 376px" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/diamonds_file_export_be.png 680w, https://support.buildsoft.eu/wp-content/uploads/2023/05/diamonds_file_export_be-300x162.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/diamonds_file_export_be-50x27.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/diamonds_file_export_be-60x32.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/diamonds_file_export_be-35x19.png 35w" alt="" width="376" height="203" /></p>
<p>The geometry model is sent to BIM Expert. All sections and materials are automatically converted and transferred, as well as the loads and results (if present). The model is now in BIM Expert.</p>
</p>
<h3>2.2 From BIM Expert to PowerConnect</h3>
<p><p>In the Model tab, select ‘Export’. Next, choose the destination software, namely PowerConnect. Click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" sizes="(max-width: 29px) 100vw, 29px" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" alt="" width="29" height="28" /> to continue.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9530 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png" alt="" width="397" height="241" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect.png 602w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-300x182.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-50x30.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-60x36.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect-35x21.png 35w" sizes="(max-width: 397px) 100vw, 397px" /></p>
<h4 id="2-2-1-settings">2.2.1 Settings</h4>
<p>You can choose to either</p>
<ul>
<li>save the model as *.bpc-file</li>
<li>send the model to the current open PowerConnect instance &#8211; you see all open instances of PowerConnect</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9533 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png" alt="" width="564" height="152" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options.png 735w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-300x81.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-50x13.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-60x16.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_options-35x9.png 35w" sizes="(max-width: 564px) 100vw, 564px" /></p>
<p>Select your choice and click <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9082" src="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png" alt="" width="29" height="28" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow.png 43w, https://support.buildsoft.eu/wp-content/uploads/2023/04/bimexpert_totekla_arrow-35x33.png 35w" sizes="(max-width: 29px) 100vw, 29px" /> to continue.</p>
<h5>2.2.2 Automatic detection of connection components</h5>
<p>BIM Expert automatically detects existing connection components in the model. You get an overview of all found connection components and whether they can be transferred to PowerConnect.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9569 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png" alt="" width="790" height="349" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total.png 1654w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-300x132.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-768x339.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-1024x452.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-50x22.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-60x26.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_componentoverview_total-35x15.png 35w" sizes="(max-width: 790px) 100vw, 790px" /></p>
<p>&nbsp;</p>
<p>Use the eye button in the &#8216;Show&#8217; column to see a detailed popup window of the connection.</p>
<p>Possible descriptions are</p>
<ul>
<li><em>Some internal forces could not be retrieved from the analysis results</em><br />
No (or not all) internal forces are present from the source software.</li>
<li><em>The connection is identical to connection(s) {IDs} and therefore has been grouped</em><br />
Identical connections will be treated as one connection. You must only calculate the connections one, with envelope forces.</li>
<li><em>Connection merged with one or more parts of the following connection: {ID}</em><br />
The connection is merged with other one to create a more complex connection (e.g. two shear connections to beam-column are merged to design a double-sided shear connection)</li>
<li><em>Connection divided into &lt;&#8230;.&gt; connections </em><br />
A complex connection has been split up into smaller PowerConnect connections</li>
<li><em>The connection bars/plates with following ID&#8217;s could not be recognized: {IDs} </em><br />
The connection is recognized and can be calculated with PowerConnect, execpt for these bars/plates, with given Ids</li>
<li><em>Connection type not support</em><br />
This connection configuration cannot be calculated by PowerConnect, so it will not be transferred.</li>
</ul>
<p>If no connections are found, you will see</p>
<p><img decoding="async" loading="lazy" class="wp-image-9573 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png" alt="" width="381" height="223" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections.png 538w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-300x176.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-50x29.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-60x35.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_noconnections-35x20.png 35w" sizes="(max-width: 381px) 100vw, 381px" /></p>
<h4>2.2.3 Add connections manually via Connection Assembler</h4>
<p>You can make your own connections by clicking ‘Modify’ (see image above).</p>
<p>In the next window, you see on the left hand side the BIM Expert model. In this window you see the regular scroll, 3D orbit and pan functions. On the right hand side, there is on top an overview of created connections and at the bottom, the &#8216;Create&#8217; button to make new connections.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9546 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png" alt="" width="712" height="356" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1.png 1553w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-300x150.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-768x384.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-1024x512.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-50x25.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-60x30.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler1-35x18.png 35w" sizes="(max-width: 712px) 100vw, 712px" /></p>
<p>In the next step you choose the connection type</p>
<ul>
<li>Moment connections: beam-column, beam-beam, splice, beam-column-beam or CHS splice</li>
<li>Shear connections: beam-column or beam-beam, beam-column-beam or beam-beam-beam</li>
<li>Base plate connections</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9537 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler2.png" alt="" width="777" height="192" /></p>
<p>After selecting for example ‘Beam to column’ you select the column and next the beam element from the 3D image on the left hand side. Click once on the column element and next on the beam element. BIM Expert will list and indicate which connections are possible:</p>
<ul>
<li>Beam to column flange &gt; possible, and marked with <img decoding="async" loading="lazy" class="alignnone size-full wp-image-9559" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_check.png" alt="" width="20" height="20" /></li>
<li>Beam to column web &gt; not possible, and not marked – you can click the orange arrow <img decoding="async" loading="lazy" class="img_inline alignnone wp-image-9558 size-full" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler_arrow.png" alt="" width="21" height="20" />at the end to fold out the details and see why this connection is not possible.</li>
</ul>
<p><img decoding="async" loading="lazy" class="wp-image-9542 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png" alt="" width="350" height="348" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3.png 587w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-150x150.png 150w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-300x298.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-50x50.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-60x60.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler3-35x35.png 35w" sizes="(max-width: 350px) 100vw, 350px" /></p>
<p>On clicking ‘Create’, the connection is added to the list of connections on top. Having selected the beam-column type, you can now continue making this type of connections, until you click ‘Change pattern’.</p>
<p><img decoding="async" loading="lazy" class=" wp-image-9543 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png" alt="" width="391" height="354" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4.png 583w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-300x271.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-50x45.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-60x54.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_assembler4-35x32.png 35w" sizes="(max-width: 391px) 100vw, 391px" /></p>
<p>When the connection definition is finished, you click ‘Close’ and ‘Accept’ to continue to PowerConnect.</p>
<p>If you have chosen to open the model directly in PowerConnect, you will get a notification in PowerConnect on the right side. You can now choose to load the model or to delete it (by using the ‘x’).</p>
<p><img decoding="async" loading="lazy" class="wp-image-9553 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png" alt="" width="403" height="160" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications.png 549w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-300x119.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-50x20.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-60x24.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_notifications-35x14.png 35w" sizes="(max-width: 403px) 100vw, 403px" /></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<h2 id="1-preparation-in-revit"><strong>3. Final steps in PowerConnect</strong></h2>
<p><p>All connections will appear in the node list on the left side (as from PowerConnect 2021).  Remember that all identical connections will be grouped as 1.</p>
<p>Connections made with the Connection Assembler might appear with a red bar and as &#8216;Undefined&#8217;.  The connector type must be chosen (e.g. end plate, shear plate, welded, angles etc)</p>
<p><img decoding="async" loading="lazy" class="wp-image-9555 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png" alt="" width="817" height="282" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined.png 1731w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-300x103.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-768x265.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-1024x353.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-50x17.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-60x21.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_undefined-35x12.png 35w" sizes="(max-width: 817px) 100vw, 817px" /></p>
<p>Click on this connection to set the connector.</p>
<p><img decoding="async" loading="lazy" class="wp-image-9554 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png" alt="" width="765" height="284" srcset="https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector.png 1729w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-300x111.png 300w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-768x285.png 768w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-1024x380.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-50x19.png 50w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-60x22.png 60w, https://support.buildsoft.eu/wp-content/uploads/2023/05/bimexpert_exporttopowerconnect_connector-35x13.png 35w" sizes="(max-width: 765px) 100vw, 765px" /></p>
<p>If no loads or internal forces were transferred, you should add loads in PowerConnect, in order to have a proper design of the connections.<script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
</p>
<p><div>
<h2 id="1-preparation-in-revit" class="wp-block-heading"><strong>4. Get started with BIM Expert<br />
</strong></h2>
</div>
<div style="text-align: left;"><div class="su-button-center"><a href="https://support.buildsoft.eu" class="su-button su-button-style-flat" style="color:#FFFFFF;background-color:#E74C3C;border-color:#b93d30;border-radius:0px" target="_blank" rel="noopener noreferrer"><span style="color:#FFFFFF;padding:8px 26px;font-size:20px;line-height:30px;border-color:#ef8277;border-radius:0px;text-shadow:none"><i class="sui sui-arrow-right" style="font-size:20px;color:#FFFFFF"></i> Download your free trial of BIM Expert</span></a></div></div>
<div><div class="su-spacer" style="height:75px"></div></div>
</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>