	<title>Errors &#8211; BuildSoft Support</title>
	<atom:link href="https://support.buildsoft.eu/article-categories/bim_errors/feed/" rel="self" type="application/rss+xml" />
	<link>https://support.buildsoft.eu</link>
	<description>BuildSoft Support</description>
	<lastBuildDate>Mon, 15 Dec 2025 15:45:18 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.2.9</generator>
	<item>
		<title>Error: Object reference not set to an instance of an object at Buildsoft.TSection.get_SectionType() in PowerConnect</title>
		<link>https://support.buildsoft.eu/knowledge-base/error-object-reference-not-set-to-an-instance-of-an-object-at-buildsoft-tsection-get_sectiontype-in-powerconnect/</link>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Tue, 12 Mar 2024 13:26:29 +0000</pubDate>
				<guid isPermaLink="false">https://support.buildsoft.eu/?post_type=ht_kb&#038;p=12626</guid>

					<description><![CDATA[Starting from Diamonds, you want to calculate a connection using PowerConnect. At the moment the connection enters PowerConnect, you get the error: Cause: this error is caused by a bug in Diamonds 2024. Solution 1 [recommended] Use Diamonds 2024r01 or newer. Solution 2 [temporary solution] If you don&#8217;t need the...]]></description>
										<content:encoded><![CDATA[<p>Starting from Diamonds, you want to calculate a connection using PowerConnect. At the moment the connection enters PowerConnect, you get the error:</p>
<p><a href="http://buildsoftsupport.com/wp-content/uploads/2020/05/ErrorTSection.get_sectionType.png"><img decoding="async" loading="lazy" class="wp-image-5317 size-full aligncenter" src="http://buildsoftsupport.com/wp-content/uploads/2020/05/ErrorTSection.get_sectionType.png" alt="" width="500" height="274" srcset="https://support.buildsoft.eu/wp-content/uploads/2020/05/ErrorTSection.get_sectionType.png 500w, https://support.buildsoft.eu/wp-content/uploads/2020/05/ErrorTSection.get_sectionType-300x164.png 300w, https://support.buildsoft.eu/wp-content/uploads/2020/05/ErrorTSection.get_sectionType-50x27.png 50w, https://support.buildsoft.eu/wp-content/uploads/2020/05/ErrorTSection.get_sectionType-60x33.png 60w, https://support.buildsoft.eu/wp-content/uploads/2020/05/ErrorTSection.get_sectionType-35x19.png 35w" sizes="(max-width: 500px) 100vw, 500px" /></a></p>
<p>Cause: this error is caused by a bug in Diamonds 2024.</p>
<h2>Solution 1 [recommended]</h2>
<p>Use Diamonds 2024r01 or newer.</p>
<h2>Solution 2 [temporary solution]</h2>
<p>If you don&#8217;t need the feature often, you could try this.</p>
<ul>
<li>Have your model calculated in Diamonds. Don&#8217;t sent the connection to PowerConnect yet.</li>
<li>Go to <strong>My Documents &gt; PowerConnect</strong>. Depending on your operating system, the name &#8216;<strong>My Documents</strong>&#8216; can be &#8216;<strong>Documents</strong>&#8216;.<img decoding="async" loading="lazy" class="alignnone size-full wp-image-10846" src="https://support.buildsoft.eu/wp-content/uploads/2018/02/PowerconnectPreferences3.png" alt="" width="959" height="287" srcset="https://support.buildsoft.eu/wp-content/uploads/2018/02/PowerconnectPreferences3.png 959w, https://support.buildsoft.eu/wp-content/uploads/2018/02/PowerconnectPreferences3-300x90.png 300w, https://support.buildsoft.eu/wp-content/uploads/2018/02/PowerconnectPreferences3-768x230.png 768w, https://support.buildsoft.eu/wp-content/uploads/2018/02/PowerconnectPreferences3-50x15.png 50w, https://support.buildsoft.eu/wp-content/uploads/2018/02/PowerconnectPreferences3-60x18.png 60w, https://support.buildsoft.eu/wp-content/uploads/2018/02/PowerconnectPreferences3-35x10.png 35w" sizes="(max-width: 959px) 100vw, 959px" /></li>
<li>Change the name of the folder &#8216;PowerConnect&#8217; to something else, &#8216;PowerConnect2&#8217; for example.</li>
<li>Open Task Manager ( <kbd>CTRL</kbd> +  <kbd>ALT</kbd> +  <kbd>DEL</kbd> or right mouse click on the Windows bar). Click on &#8216;More details&#8217;.<img decoding="async" loading="lazy" class="size-full wp-image-3898 aligncenter" src="http://buildsoftsupport.com/wp-content/uploads/2017/07/ConnectGatewaytoGatewayServer1.png" alt="" width="379" height="372" srcset="https://support.buildsoft.eu/wp-content/uploads/2017/07/ConnectGatewaytoGatewayServer1.png 379w, https://support.buildsoft.eu/wp-content/uploads/2017/07/ConnectGatewaytoGatewayServer1-300x294.png 300w, https://support.buildsoft.eu/wp-content/uploads/2017/07/ConnectGatewaytoGatewayServer1-50x50.png 50w, https://support.buildsoft.eu/wp-content/uploads/2017/07/ConnectGatewaytoGatewayServer1-60x60.png 60w, https://support.buildsoft.eu/wp-content/uploads/2017/07/ConnectGatewaytoGatewayServer1-35x35.png 35w" sizes="(max-width: 379px) 100vw, 379px" /></li>
<li>Go to the tabpage &#8216;Services&#8217;.</li>
<li>Find the service &#8216;Gateway&#8217; &gt; right mouse button &gt; ‘Stop’.<br />
Find the service &#8216;Gateway Server&#8217; &gt; right mouse button &gt; ‘Stop’.</li>
<li>Select the connection and send it to PowerConnect as you normally would do. Once PowerConnect wants to launch, you&#8217;ll see the following:<br />
<img decoding="async" loading="lazy" class="alignnone size-full wp-image-12627" src="https://support.buildsoft.eu/wp-content/uploads/2024/03/ErrorPowerConnect2024.png" alt="" width="509" height="367" /></li>
<li>Open Task Manager again ( <kbd>CTRL</kbd> +  <kbd>ALT</kbd> +  <kbd>DEL</kbd> or right mouse click on the Windows bar). Click on &#8216;More details&#8217;.</li>
<li>Go to the tabpage &#8216;Services&#8217;.</li>
<li>Find the service &#8216;Gateway&#8217; &gt; right mouse button &gt; ‘Start’.<br />
Find the service &#8216;Gateway Server&#8217; &gt; right mouse button &gt; ‘Start’.</li>
<li>Close Task Manager.</li>
<li>Design the connection like you would normally do.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Error: Not enough quota is available to process the command</title>
		<link>https://support.buildsoft.eu/knowledge-base/not-enough-quota-is-available-to-process-the-command/</link>
		
		<dc:creator><![CDATA[Dorothee]]></dc:creator>
		<pubDate>Tue, 09 Aug 2022 10:18:13 +0000</pubDate>
				<guid isPermaLink="false">https://support.buildsoft.eu/?post_type=ht_kb&#038;p=7741</guid>

					<description><![CDATA[When sending a model to Idea Statica Connection through BIM Expert, you get this error in Checkbot Critical Error An unrecoverable error occurred in the application an it is going to be terminated. Error details: Not enough quota is available to process the comman Solution This error is usually to...]]></description>
										<content:encoded><![CDATA[<p>When sending a model to Idea Statica Connection through BIM Expert, you get this error in Checkbot</p>
<p><em>Critical Error</em></p>
<p><em>An unrecoverable error occurred in the application an it is going to be terminated. Error details: Not enough quota is available to process the comman</em><img decoding="async" loading="lazy" class="size-full wp-image-7742 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2022/08/bimexpert_idea_error_tomanycombos.png" alt="" width="496" height="218" srcset="https://support.buildsoft.eu/wp-content/uploads/2022/08/bimexpert_idea_error_tomanycombos.png 496w, https://support.buildsoft.eu/wp-content/uploads/2022/08/bimexpert_idea_error_tomanycombos-300x132.png 300w, https://support.buildsoft.eu/wp-content/uploads/2022/08/bimexpert_idea_error_tomanycombos-50x22.png 50w, https://support.buildsoft.eu/wp-content/uploads/2022/08/bimexpert_idea_error_tomanycombos-60x26.png 60w, https://support.buildsoft.eu/wp-content/uploads/2022/08/bimexpert_idea_error_tomanycombos-35x15.png 35w" sizes="(max-width: 496px) 100vw, 496px" /></p>
<h2>Solution</h2>
<p>This error is usually to a large number of data (e.g. load combinations), which cannot be processed properly.</p>
<ol>
<li>Click &#8216;Ok&#8217; to close this error message. Checkbot will close to.</li>
<li>Open Idea Statica &gt; BIM &gt; Checkbot</li>
<li>Create a new project (in a new folder preferably)</li>
<li>Click &#8216;Import IOM&#8217; and select <strong>&lt;modelname&gt;-ModelBim.xml </strong>from the original exchange folder.</li>
</ol>
<p style="font-size: 12px; text-align: center; background-color: #f4f5f5;">IDEA STATICA is a registered trademark of IDEA RS s.r.o.</p>

]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Error: It was not possible to convert the model: An item with the same key has already been added</title>
		<link>https://support.buildsoft.eu/knowledge-base/error-it-was-not-possible-to-convert-the-model-an-item-with-the-same-key-has-already-been-added/</link>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Mon, 11 Jul 2022 14:16:39 +0000</pubDate>
				<guid isPermaLink="false">https://support.buildsoft.eu/?post_type=ht_kb&#038;p=7724</guid>

					<description><![CDATA[When importing a Diamonds model into BIM Expert, following error message appears: Solution Check the Diamonds model for internal plates. If there are any present, resolve them.]]></description>
										<content:encoded><![CDATA[<p>When importing a Diamonds model into BIM Expert, following error message appears:</p>
<p><img decoding="async" loading="lazy" class="size-full wp-image-7725 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2022/07/ErrorItWasNotPossibleToConvertTheModel.png" alt="" width="824" height="181" srcset="https://support.buildsoft.eu/wp-content/uploads/2022/07/ErrorItWasNotPossibleToConvertTheModel.png 824w, https://support.buildsoft.eu/wp-content/uploads/2022/07/ErrorItWasNotPossibleToConvertTheModel-300x66.png 300w, https://support.buildsoft.eu/wp-content/uploads/2022/07/ErrorItWasNotPossibleToConvertTheModel-768x169.png 768w, https://support.buildsoft.eu/wp-content/uploads/2022/07/ErrorItWasNotPossibleToConvertTheModel-50x11.png 50w, https://support.buildsoft.eu/wp-content/uploads/2022/07/ErrorItWasNotPossibleToConvertTheModel-60x13.png 60w, https://support.buildsoft.eu/wp-content/uploads/2022/07/ErrorItWasNotPossibleToConvertTheModel-35x8.png 35w" sizes="(max-width: 824px) 100vw, 824px" /></p>
<h3>Solution</h3>
<ul>
<li>Check the Diamonds model <a href="https://support.buildsoft.eu/knowledge-base/what-are-internal-plates/">for internal plates</a>. If there are any present, resolve them.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Cannot connect to Gateway on Server</title>
		<link>https://support.buildsoft.eu/knowledge-base/cannot-connect-to-gateway-on-server/</link>
		
		<dc:creator><![CDATA[Dorothee]]></dc:creator>
		<pubDate>Thu, 30 Jun 2022 09:50:48 +0000</pubDate>
				<guid isPermaLink="false">https://support.buildsoft.eu/?post_type=ht_kb&#038;p=7704</guid>

					<description><![CDATA[Gateway Server is installed on server machine and users are created. From the client machine, it takes a long time to load the libraries and BIM Expert hangs. Solution Test if the ports you have set in the Gateway Configuration Tool (default 501 &#38; 502) in are open on the...]]></description>
										<content:encoded><![CDATA[<p>Gateway Server is installed on server machine and users are created. From the client machine, it takes a long time to load the libraries and BIM Expert hangs.</p>
<h2>Solution</h2>
<p>Test if the ports you have set in the Gateway Configuration Tool (default 501 &amp; 502) in are open on the server machine:</p>
<ol>
<li>Open Windows PowerShell</li>
<li>Typ <code>tnc {ip_server} -Port {port_number}</code></li>
<li>Fix the failed checks by opening the ports</li>
</ol>
<p><em>Example</em></p>
<p><img decoding="async" loading="lazy" class="wp-image-7705 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2022/06/gateway_powershell_portcheck.png" alt="" width="516" height="448" srcset="https://support.buildsoft.eu/wp-content/uploads/2022/06/gateway_powershell_portcheck.png 843w, https://support.buildsoft.eu/wp-content/uploads/2022/06/gateway_powershell_portcheck-300x260.png 300w, https://support.buildsoft.eu/wp-content/uploads/2022/06/gateway_powershell_portcheck-768x667.png 768w, https://support.buildsoft.eu/wp-content/uploads/2022/06/gateway_powershell_portcheck-50x43.png 50w, https://support.buildsoft.eu/wp-content/uploads/2022/06/gateway_powershell_portcheck-60x52.png 60w, https://support.buildsoft.eu/wp-content/uploads/2022/06/gateway_powershell_portcheck-35x30.png 35w" sizes="(max-width: 516px) 100vw, 516px" /></p>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
<div id="ConnectiveDocSignExtentionInstalled" data-extension-version="1.0.4"></div>
<p><script src="moz-extension://ccccaaeb-013b-4b99-be98-cffa5aa77072/js/app.js" type="text/javascript"></script></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Error: It was not possible to convert the model: Could not load file or assembly &#8216;DiamondsDeclarations</title>
		<link>https://support.buildsoft.eu/knowledge-base/it-was-not-possible-to-convert-the-model-could-not-load-file-or-assembly-diamondsdeclarations/</link>
		
		<dc:creator><![CDATA[Dorothee]]></dc:creator>
		<pubDate>Thu, 18 Nov 2021 11:45:01 +0000</pubDate>
				<guid isPermaLink="false">https://buildsoftsupport.com/?post_type=ht_kb&#038;p=6920</guid>

					<description><![CDATA[When importing a Diamonds model into BIM Expert, following error message appears It was not possible to convert the model: Could not load file or assembly &#8216;DiamondsDeclarations, version= &#8230;. Solution The file &#8216;DiamondsDeclarations&#8217; is required for the import, but not found in the BIM Expert installations folder. (C:\Program Files (x86)\BuildSoft\BIM...]]></description>
										<content:encoded><![CDATA[<p>When importing a Diamonds model into BIM Expert, following error message appears</p>
<p><em>It was not possible to convert the model: Could not load file or assembly &#8216;DiamondsDeclarations, version= &#8230;.</em></p>
<p><img decoding="async" loading="lazy" class="wp-image-6921 aligncenter" src="https://buildsoftsupport.com/wp-content/uploads/2021/11/bimexpert_error_diamondsimport.png" alt="" width="879" height="98" srcset="https://support.buildsoft.eu/wp-content/uploads/2021/11/bimexpert_error_diamondsimport.png 1473w, https://support.buildsoft.eu/wp-content/uploads/2021/11/bimexpert_error_diamondsimport-300x33.png 300w, https://support.buildsoft.eu/wp-content/uploads/2021/11/bimexpert_error_diamondsimport-768x86.png 768w, https://support.buildsoft.eu/wp-content/uploads/2021/11/bimexpert_error_diamondsimport-1024x114.png 1024w, https://support.buildsoft.eu/wp-content/uploads/2021/11/bimexpert_error_diamondsimport-50x6.png 50w, https://support.buildsoft.eu/wp-content/uploads/2021/11/bimexpert_error_diamondsimport-60x7.png 60w, https://support.buildsoft.eu/wp-content/uploads/2021/11/bimexpert_error_diamondsimport-35x4.png 35w" sizes="(max-width: 879px) 100vw, 879px" /></p>
<h2>Solution</h2>
<p>The file &#8216;DiamondsDeclarations&#8217; is required for the import, but not found in the BIM Expert installations folder. (C:\Program Files (x86)\BuildSoft\BIM Expert\Plugins\Diamonds)</p>
<ol>
<li>Close BIM Expert</li>
<li>Uninstall BIM Expert</li>
<li>Reinstall BIM Expert</li>
</ol>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Error: The application was unable to start correctly (0xc0000005).</title>
		<link>https://support.buildsoft.eu/knowledge-base/error-the-application-was-unable-to-start-correctly-0xc0000005/</link>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Tue, 25 May 2021 11:39:09 +0000</pubDate>
				<guid isPermaLink="false">https://buildsoftsupport.com/?post_type=ht_kb&#038;p=6570</guid>

					<description><![CDATA[When starting Diamonds/PowerConnect or BIM Expert, you get the error: [NL]: Kan applicatie niet correct starten (0xc0000005). Klik op OK om de toepassing te sluiten. [FR]: L&#8217;application n&#8217;a pas réussi à demarrer correctement (0xc0000005). Cliquez sur OK pour fermer l&#8217;application. Solution This error is caused by Avast Anti-virus who blocks the...]]></description>
										<content:encoded><![CDATA[<p>When starting Diamonds/PowerConnect or BIM Expert, you get the error:</p>
<p><img decoding="async" loading="lazy" class="aligncenter wp-image-6571" src="https://buildsoftsupport.com/wp-content/uploads/2021/05/Error0xc0000005.png" alt="" width="575" height="200" srcset="https://support.buildsoft.eu/wp-content/uploads/2021/05/Error0xc0000005.png 868w, https://support.buildsoft.eu/wp-content/uploads/2021/05/Error0xc0000005-300x104.png 300w, https://support.buildsoft.eu/wp-content/uploads/2021/05/Error0xc0000005-768x267.png 768w, https://support.buildsoft.eu/wp-content/uploads/2021/05/Error0xc0000005-50x17.png 50w, https://support.buildsoft.eu/wp-content/uploads/2021/05/Error0xc0000005-60x21.png 60w, https://support.buildsoft.eu/wp-content/uploads/2021/05/Error0xc0000005-35x12.png 35w" sizes="(max-width: 575px) 100vw, 575px" /></p>
[NL]: Kan applicatie niet correct starten (0xc0000005). Klik op OK om de toepassing te sluiten.</p>
[FR]: L&#8217;application n&#8217;a pas réussi à demarrer correctement (0xc0000005). Cliquez sur OK pour fermer l&#8217;application.</p>
<h2>Solution</h2>
<p>This error is caused by Avast Anti-virus who blocks the start of our software.</p>
<ul>
<li>As a test, you could de-activate Avast for 10 minutes and try to start or software.</li>
<li>As a permanent solution, you should add an exception for our software in Avast Anti-virus.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Error: an internal system error occured</title>
		<link>https://support.buildsoft.eu/knowledge-base/error-an-internal-system-error-occured/</link>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Tue, 17 Nov 2020 09:18:44 +0000</pubDate>
				<guid isPermaLink="false">https://buildsoftsupport.com/?post_type=ht_kb&#038;p=6045</guid>

					<description><![CDATA[When installing BIM Expert, you get the error: [EN]: An internal system error occured. Please refer to DXError.log and DirectX.log in your Windows folder to determine problem. [NL]: Er is een interne systeemfout opgetreden. Raadpleeg DXError.log en DirectX.log in de map Windows om vast te stellen wat het probleem is. [FR]:...]]></description>
										<content:encoded><![CDATA[<p>When installing BIM Expert, you get the error:</p>
<p><img decoding="async" loading="lazy" class="size-full wp-image-6046 aligncenter" src="https://buildsoftsupport.com/wp-content/uploads/2020/11/ErrorDXError.jpg" alt="" width="514" height="192" srcset="https://support.buildsoft.eu/wp-content/uploads/2020/11/ErrorDXError.jpg 514w, https://support.buildsoft.eu/wp-content/uploads/2020/11/ErrorDXError-300x112.jpg 300w, https://support.buildsoft.eu/wp-content/uploads/2020/11/ErrorDXError-50x19.jpg 50w, https://support.buildsoft.eu/wp-content/uploads/2020/11/ErrorDXError-60x22.jpg 60w, https://support.buildsoft.eu/wp-content/uploads/2020/11/ErrorDXError-35x13.jpg 35w" sizes="(max-width: 514px) 100vw, 514px" /></p>
[EN]: <em>An internal system error occured. Please refer to DXError.log and DirectX.log in your Windows folder to determine problem.</em></p>
[NL]: <em>Er is een interne systeemfout opgetreden. Raadpleeg DXError.log en DirectX.log in de map Windows om vast te stellen wat het probleem is.</em></p>
[FR]: <em>Une erreur système interne s&#8217;est produite. Consultez les fichiers DXerror.log et DirectX.log situés dans le dossier Windows pour déterminer le problème. </em></p>
[ES]: Error interno del sistema. Wea el archivo de registro DXError.log y DirectX.log en la carpeta Windows para determinar el problema.</p>
<h2>Solution</h2>
<ul>
<li>Download DirectX from the<a href="https://www.microsoft.com/nl-be/download/details.aspx?id=35"> Microsoft website.</a></li>
<li>Install DirectX.</li>
<li>Run the BIM Expert installer again.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Error: An error occured while downloading the file http://www.buildsoft.eu/downloads/tempsoft/&#8230;</title>
		<link>https://support.buildsoft.eu/knowledge-base/an-error-occured-while-downloading-the-file-httpwww-buildsoft-eudownloadstempsoft/</link>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Tue, 09 Jun 2020 08:13:41 +0000</pubDate>
				<guid isPermaLink="false">http://buildsoftsupport.com/?post_type=ht_kb&#038;p=5420</guid>

					<description><![CDATA[While running the Diamonds, PowerConnect or BIM Expert installer, you the the error: Solution Close/stop the installation. Download and install Gateway. Run the Diamonds, BIM Expert, PowerConnect installer again. Right mouse click on *.exe &#62; Run as Administrator. Install Gateway with default settings. Run the Diamonds/ PowerConnect or BIM Expert...]]></description>
										<content:encoded><![CDATA[<p>While running the Diamonds, PowerConnect or BIM Expert installer, you the the error:</p>
<p><a href="http://buildsoftsupport.com/wp-content/uploads/2020/06/ErrorDownloadGateway.png"><img decoding="async" loading="lazy" class="wp-image-5421 size-full aligncenter" src="http://buildsoftsupport.com/wp-content/uploads/2020/06/ErrorDownloadGateway.png" alt="" width="461" height="349" srcset="https://support.buildsoft.eu/wp-content/uploads/2020/06/ErrorDownloadGateway.png 461w, https://support.buildsoft.eu/wp-content/uploads/2020/06/ErrorDownloadGateway-300x227.png 300w, https://support.buildsoft.eu/wp-content/uploads/2020/06/ErrorDownloadGateway-50x38.png 50w, https://support.buildsoft.eu/wp-content/uploads/2020/06/ErrorDownloadGateway-60x45.png 60w, https://support.buildsoft.eu/wp-content/uploads/2020/06/ErrorDownloadGateway-35x26.png 35w" sizes="(max-width: 461px) 100vw, 461px" /></a></p>
<h2>Solution</h2>
<ul>
<li>Close/stop the installation.</li>
<li><a href="https://support.buildsoft.eu/knowledge-base/where-can-i-download-gateway/">Download </a>and install Gateway.</li>
<li>Run the Diamonds, BIM Expert, PowerConnect installer again.</li>
<li>Right mouse click on *.exe &gt; Run as Administrator.</li>
<li>Install Gateway with default settings.</li>
<li>Run the Diamonds/ PowerConnect or BIM Expert again.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>BIM Expert shows splash screen and closes</title>
		<link>https://support.buildsoft.eu/knowledge-base/bim-expert-shows-splash-screen-and-closes/</link>
		
		<dc:creator><![CDATA[Dorothee]]></dc:creator>
		<pubDate>Wed, 23 Oct 2019 08:27:30 +0000</pubDate>
				<guid isPermaLink="false">http://buildsoftsupport.com/?post_type=ht_kb&#038;p=4723</guid>

					<description><![CDATA[BIM Expert shows his splash screen and closes immediately after. Solution update the firmware of the dongle.]]></description>
										<content:encoded><![CDATA[<p>BIM Expert shows his splash screen and closes immediately after.</p>
<h2>Solution</h2>
<ul>
<li><a href="http://buildsoftsupport.com/knowledge-base/update-firmware-of-dongle/">update the firmware of the dongle</a>.</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>BIM Expert doesn&#8217;t start</title>
		<link>https://support.buildsoft.eu/knowledge-base/bim-expert-doesnt-start/</link>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Tue, 16 Jul 2019 10:02:14 +0000</pubDate>
				<guid isPermaLink="false">http://buildsoftsupport.com/?post_type=ht_kb&#038;p=4503</guid>

					<description><![CDATA[BIM Expert doesn&#8217;t start. BIM Expert remains stuck on the splash screen. Solution You need to update the firmware of the dongle.]]></description>
										<content:encoded><![CDATA[<p>BIM Expert doesn&#8217;t start. BIM Expert remains stuck on the splash screen.</p>
<p><img decoding="async" loading="lazy" class="aligncenter wp-image-4504 size-medium" src="http://buildsoftsupport.com/wp-content/uploads/2019/07/image001-300x180.jpg" alt="" width="300" height="180" srcset="https://support.buildsoft.eu/wp-content/uploads/2019/07/image001-300x180.jpg 300w, https://support.buildsoft.eu/wp-content/uploads/2019/07/image001-50x30.jpg 50w, https://support.buildsoft.eu/wp-content/uploads/2019/07/image001-60x36.jpg 60w, https://support.buildsoft.eu/wp-content/uploads/2019/07/image001-35x21.jpg 35w, https://support.buildsoft.eu/wp-content/uploads/2019/07/image001.jpg 500w" sizes="(max-width: 300px) 100vw, 300px" /></p>
<h1>Solution</h1>
<p>You need to <a href="http://buildsoftsupport.com/knowledge-base/update-firmware-of-dongle/">update the firmware of the dongle</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>