<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Good to know &#8211; BuildSoft Support</title>
	<atom:link href="https://support.buildsoft.eu/article-categories/12build_goodtoknow/feed/" rel="self" type="application/rss+xml" />
	<link>https://support.buildsoft.eu</link>
	<description>BuildSoft Support</description>
	<lastBuildDate>Fri, 06 Jun 2025 14:39:20 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.2.15</generator>
	<item>
		<title>Relocate the 12-Build preferences</title>
		<link>https://support.buildsoft.eu/knowledge-base/relocate-the-12build-preferences/</link>
		
		<dc:creator><![CDATA[Dorothee]]></dc:creator>
		<pubDate>Tue, 20 Jun 2023 14:47:32 +0000</pubDate>
				<guid isPermaLink="false">https://support.buildsoft.eu/?post_type=ht_kb&#038;p=9874</guid>

					<description><![CDATA[Close all 12-Build projects. Create a folder on the Desktop or in Documents folder. Name it ‘12Build_prefs‘. Go to C:\Program Files (x86)\BuildSoft\12Build and look for the file 12Build.ini  Copy this file to your desktop. Open the file with Notepad and change the Dir location to [Path pref] Dir=C:\Users\**YourUsername**\Documents\12Build_prefs\ (Replace Documents...]]></description>
										<content:encoded><![CDATA[<ol>
<li>Close all 12-Build projects.</li>
<li>Create a folder on the <em>Desktop</em> or in <em>Documents</em> folder. Name it ‘<em>12Build_prefs</em>‘.</li>
<li>Go to <strong>C:\Program Files (x86)\BuildSoft\12Build </strong>and look for the file <em>12Build.ini  </em>Copy this file to your desktop.</li>
<li>Open the file with Notepad and change the <strong>Dir</strong> location to
<pre>[Path pref]
Dir=C:\Users\**YourUsername**\Documents\12Build_prefs\</pre>
<p>(Replace Documents by Desktop, if you have chosen Desktop)</li>
<li>Save this file</li>
<li>Copy this file and paste it to 2 locations: the installation folder and AppData folder
<ul>
<li><em>Installation folder</em>: <strong>C:\Program Files (x86)\BuildSoft\12Build</strong></li>
<li><em>App data folder</em>: Go to <strong>C:\Users\**YourUsername**\AppData\Local\VirtualStore\Program Files (x86)\BuildSoft\12Build</strong><br />
Note: the folder ‘AppData’ is a hidden folder. You can show the hidden folders in the <a href="https://support.microsoft.com/en-us/help/14201/windows-show-hidden-files">folder options</a>.</li>
</ul>
</li>
<li>Copy the contents of the Appdata folder to the <em>12Build_prefs</em> folder</li>
<li>Launch 12-Build. 12-Build should start in a normal way.</li>
</ol>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to convert a 12-Build model to Diamonds</title>
		<link>https://support.buildsoft.eu/knowledge-base/how-to-convert-a-12build-model-to-diamonds/</link>
		
		<dc:creator><![CDATA[Dorothee]]></dc:creator>
		<pubDate>Thu, 04 Feb 2021 09:33:19 +0000</pubDate>
				<guid isPermaLink="false">https://buildsoftsupport.com/?post_type=ht_kb&#038;p=6255</guid>

					<description><![CDATA[How to import a 12Build file in Diamonds:]]></description>
										<content:encoded><![CDATA[
<p>How to import a 12Build file in Diamonds:</p>



<ol>
<li>Make sure you only have one model in the 12Build file.</li>



<li>In 12-Build go to &#8216;File &gt; Export&#8217;&nbsp; and &#8216;Save as type&#8217; : PowerFrame (.ef3)</li>



<li>Open Diamonds.</li>



<li>Drag and drop the Powerframe-file into Diamonds.</li>
</ol>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Cross sections/ profiles in PowerFrame/ 12-Build</title>
		<link>https://support.buildsoft.eu/knowledge-base/cross-sections-profiles-in-powerframe-12-build/</link>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Tue, 26 Feb 2019 14:41:13 +0000</pubDate>
				<guid isPermaLink="false">http://buildsoftsupport.com/?post_type=ht_kb&#038;p=4005</guid>

					<description><![CDATA[Product catalog Arcelor Mittal.]]></description>
										<content:encoded><![CDATA[
<ul>
<li>Download the pdf version from the attachment below.</li>



<li>If the desired profile is not in the list, you can always create it in PowerFrame.<br>The section library of 12-Build is not editable.</li>
</ul>



<p>Product <a href="https://sections.arcelormittal.com/repo/Sections/Sections_MB_ArcelorMittal_FR_EN_DE.pdf">catalog</a> Arcelor Mittal.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to reset the 12-Build preferences</title>
		<link>https://support.buildsoft.eu/knowledge-base/how-to-reset-the-1-2-build-preferences/</link>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Wed, 17 Jan 2018 10:38:55 +0000</pubDate>
				<guid isPermaLink="false">http://buildsoftsupport.com/?post_type=ht_kb&#038;p=2269</guid>

					<description><![CDATA[About the Preferences ‘Preferences’ are settings that are user dependant, for example: Units and decimals The language Colors … At the first startup of 12-Build, 12-Build takes the default values (stored in the Program Files). When you work with 12-Build, you will customize these settings along the way. Workflow to reset...]]></description>
										<content:encoded><![CDATA[<h2>About the Preferences</h2>
<p>‘<strong>Preferences’ </strong>are settings that are user dependant, for example:</p>
<ul>
<li>Units and decimals</li>
<li>The language</li>
<li>Colors</li>
<li>…</li>
</ul>
<p>At the first startup of 12-Build, 12-Build takes the default values (stored in the Program Files). When you work with 12-Build, you will customize these settings along the way.</p>
<h2>Workflow to reset the preferences</h2>
<ol>
<li>Close all 1·2·Build projects.</li>
<li>Go to <strong>C:\Users\**YourUsername**\AppData\Local\VirtualStore\Program Files (x86)\BuildSoft\1 2 Build. </strong><br />
The folder &#8220;AppData&#8221; is a hidden folder. IYou can show the hidden folders using the menu &#8220;View &gt; View &gt; Show hidden items&#8221;.<br />
If you see the folder &#8220;AppData&#8221; now, skip step 3 and go to step 4.<br />
If you still don&#8217;t see the folder &#8220;AppData&#8221; now, go to step 3.<br />
<img decoding="async" loading="lazy" class="alignnone size-full wp-image-15264" src="https://support.buildsoft.eu/wp-content/uploads/2018/01/PRefs12Build1b.png" alt="" width="1464" height="735" /></li>
<li>Go to <strong>C:\Program Files (x86)\BuildSoft\12Build<br />
</strong>Sort the content of this folder by date.<br />
The preferences are stored in the same folder as the installation files. You can detect the preference files by sorting the folder by date. The preferences always have a more recent date. While the installation files have older dates. This 1·2·Build is from 2021. Anything more recent than 2021 is a preference file, thus all files above the line are preference files.<br />
Select all preference files and delete them. Then, skip step 4 and go to step 5.<strong><br />
<img decoding="async" loading="lazy" class="alignnone size-full wp-image-15265" src="https://support.buildsoft.eu/wp-content/uploads/2018/01/PRefs12Build2.png" alt="" width="1114" height="778" /><br />
</strong></li>
<li>Delete the content of this folder.</li>
<li>Restart 12-Build.<br />
If do did the procedure correctly, 12-Build will ask you the language.<img decoding="async" loading="lazy" class="wp-image-13845 aligncenter" src="https://support.buildsoft.eu/wp-content/uploads/2018/01/12BuildLanguage.png" alt="" width="350" height="229" /></li>
</ol>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Can loads be applied around the weak axis of a cross section?</title>
		<link>https://support.buildsoft.eu/knowledge-base/can-loads-be-applied-around-the-weak-axis-of-a-cross-section/</link>
					<comments>https://support.buildsoft.eu/knowledge-base/can-loads-be-applied-around-the-weak-axis-of-a-cross-section/#respond</comments>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Fri, 09 Jun 2017 08:38:57 +0000</pubDate>
				<guid isPermaLink="false">http://buildsoftsupport.com/?post_type=ht_kb&#038;p=1052</guid>

					<description><![CDATA[No, that is not possible in 12 Build. In our more advanced software Diamonds, this is possible.]]></description>
										<content:encoded><![CDATA[
<p>No, that is not possible in 12 Build. In our more advanced software <a href="https://support.buildsoft.eu/article-categories/diamonds/">Diamonds</a>, this is possible.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://support.buildsoft.eu/knowledge-base/can-loads-be-applied-around-the-weak-axis-of-a-cross-section/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>What is the meaning of the 3 numbers next to the shear reinforcement?</title>
		<link>https://support.buildsoft.eu/knowledge-base/what-is-the-meaning-the-3-numbers-next-to-the-shear-reinforcement/</link>
					<comments>https://support.buildsoft.eu/knowledge-base/what-is-the-meaning-the-3-numbers-next-to-the-shear-reinforcement/#respond</comments>
		
		<dc:creator><![CDATA[Dorien Elleboog]]></dc:creator>
		<pubDate>Fri, 09 Jun 2017 08:33:45 +0000</pubDate>
				<guid isPermaLink="false">http://buildsoftsupport.com/?post_type=ht_kb&#038;p=1047</guid>

					<description><![CDATA[The numbers are 84/140/84 in the image below. They represent the intermediary distance between the stirrups. Near the ends of the column the stirrups must be closer to each other in accordance with EN 1992-1-1 §9.5.3 (3) and (4). 140mm * 0.6 = 84mm.]]></description>
										<content:encoded><![CDATA[
<p>The numbers are 84/140/84 in the image below. They represent the intermediary distance between the stirrups. Near the ends of the column the stirrups must be closer to each other in accordance with EN 1992-1-1 §9.5.3 (3) and (4). 140mm * 0.6 = 84mm.</p>



<figure class="wp-block-image aligncenter"><img decoding="async" loading="lazy" width="180" height="300" src="http://buildsoftsupport.com/wp-content/uploads/2017/06/ShearReinforcement12Build-1-180x300.png" alt="" class="wp-image-1049" srcset="https://support.buildsoft.eu/wp-content/uploads/2017/06/ShearReinforcement12Build-1-180x300.png 180w, https://support.buildsoft.eu/wp-content/uploads/2017/06/ShearReinforcement12Build-1-30x50.png 30w, https://support.buildsoft.eu/wp-content/uploads/2017/06/ShearReinforcement12Build-1-36x60.png 36w, https://support.buildsoft.eu/wp-content/uploads/2017/06/ShearReinforcement12Build-1-21x35.png 21w, https://support.buildsoft.eu/wp-content/uploads/2017/06/ShearReinforcement12Build-1.png 211w" sizes="(max-width: 180px) 100vw, 180px" /></figure>
]]></content:encoded>
					
					<wfw:commentRss>https://support.buildsoft.eu/knowledge-base/what-is-the-meaning-the-3-numbers-next-to-the-shear-reinforcement/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
